Original source · versioned page text
20230033 23 Beckmans Concept Dway Layout
PROVIDE 6m WIDE DRIVEWAY
CROSSOVER TYPICALLY IN ACCORDANCE
17
VIP RL 21.695 PROPERTY
VIP RL 22.157 ROAD CL
WITH NSC STD DWG RS-056
19
BDY
VIP RL 22.013
VIP RL 21.054
VIP RL 21.13
18
20
HORIZONTAL CURVE DATA R 12
VERTICAL CURVE LENGTH (m)
18
VERTICAL CURVE RADIUS (m)
REFER TO ARCHITECTURAL VERTICAL GEOMETRY GRADE (%) -4.1%-6% -9.8% -0.4%
VERTICAL GEOMETRY LENGTH (m) 3.48 5.28 5.78 18.21
PLANS FOR INTERNAL
CONFIGURATION DATUM RL = 15.400
20.
10.
0m
0m
22.157
22.013
21.695
21.595
21.574
21.130
21.107
21.072
21.066
21.054
FINISHED SURFACE LEVEL
0.0
m
30
.0m 20
21
19
22.156
22.013
21.695
21.574
21.539
21.124
20.698
21.069
21.100
21.054
EXISTING SURFACE LEVEL
32
.8m
CUT / FILL DEPTH
-0.035
0.001
0.000
0.000
0.022
0.035
0.006
0.409
0.003
0.000
CONTROL LINE CHAINAGE
20
14.538
28.361
32.752
3.482
9.781
8.76
10
20
30
0
A1 SCALE: H 1:500, V 1:100
INDICATIVE LONGITUDINAL SECTION DWAY
23
24
22
21
24
30
PROPERTY BOUNDARY
VIP RL 22.157
VIP RL 22.013
VIP RL 21.695
B9
STANDARDS 2004 (AU_NZ9)
VIP RL 21.054
VIP RL 21.13
(c)2023
(c) 2023Transoft
TransoftSolutions,
Solutions,Inc.
Inc.All
Allrights
rightsreserved.
reserved.
B99
STANDARDS 2004 (AU_NZ)
(c)
(c)2023
2023Transoft
TransoftSolutions,
Solutions,Inc.
Inc.All
Allrights
rightsreserved.
reserved.
R 12
Ground Clearance (units: m)
Part # Front Wheelbase Rear
#1 0.12 0.12 0.12
-4.1% -6% -9.8% -0.4%
3.48 5.28 5.78 18.21
VERTICAL CLEARANCE CHECK
A1 SCALE: 1:100
North Point Approved Project Address Title
BEN PARRY
28084 23 BECKMANS RD CONCEPT DRIVEWAY ACCESS PLAN
TEWANTIN, 4565
For and on behalf of RECOR Pty Ltd. QLD, AUSTRALIA
Scale ENGINEERING + PROJECT MANAGEMENT Client Details PROJECT NAME: Project Number Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
www.recorconsulting.com | ABN 89 647 469 707 MARK BAIN CONSTRUCTIONS 23 BECKMANS ROAD 20230033 A1
01 24/03/2023 RFI ISSUE BP BP
1:500 COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This PTY LTD Drawing Number Revision
010 01
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction' in
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK the revision description.