Site Catchment Areas for DRAINS Modelling
Project number:    20220116                                         Calculations:                       B. Parry
Street Address:    206 David Low Way
Locality:          Peregian Beach, NSC                              Date:                               17/03/2023


Existing Site
                                            Existing Site           Directly connected (m²)             Indirectly connected (m²)
206 David Low Way Roof                                      132.6                               132.6                                  -
                  Impervious Ground                          21.7                                 -                                   21.7
                  Driveway                                   23.3                                23.3                                  -

                   Total Imp                                177.6                               155.9                                 21.7
                   Total Per                                340.1                                 -                                  340.1
                   Site Area                                517.7                               155.9                                 21.7

% impervious                                                        Effective DCIA = 75% DCIA           ICIA +25% ineffective DCIA
                                                                                                116.9                                 60.7
                   Impervious                               34.3%                               22.6%                                11.7%
                   Pervious                                 65.7%



Proposed Site



                                            Proposed                Directly connected (m²)             Indirectly connected (m²)
206 David Low Way Roof                                      236.4                               236.4                                  -
                  Impervious Ground                          88.8                                 -                                   88.8
                  Driveway                                   65.7                                65.7

                   Total Imp                                390.9                               302.1                                 88.8
                   Total Per                                126.8                                 -                                  126.8
                   Site Area                                517.7                               302.1                                215.6

% impervious                                                        Effective DCIA = 75% DCIA           ICIA +25% ineffective DCIA
                                                                                                226.6                                164.4
                   Impervious                               75.5%                               43.8%                                31.8%
                   Pervious                                 24.5%
Log in to download the original file

SWMP.pdf · 7.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.