DRAINS Modelling Results Project number: 20220116 Calculations: B. Parry Street Address: 206 David Low Way Locality: Peregian Beach, NSC Date: 17/03/2023 Pre / Post Comparison 3 3 3 A.E.P Qy Pre (m /s) Qy Post (m /s) Qchange (m /s) Qchange (%) 1 EY 0.014 0.015 0.001 7% 50% AEP 0.016 0.018 0.002 13% 0.2 EY 0.024 0.026 0.002 8% 10% AEP 0.031 0.031 0.000 0% 5% AEP 0.035 0.036 0.001 3% 2% AEP 0.041 0.041 0.000 0% 1% AEP 0.046 0.045 -0.001 -2% Pre / Post w/ OSD Comparison Tank Node Assumptions 3 3 3 A.E.P Qy Pre (m /s) Qy Post (m /s) Qchange (m /s) Qchange (%) https://kingspanwatertanks.com.au/product/2000-litre-skinny-slimline-water-tank/ 1 EY 0.014 0.013 -0.001 -7% 2x2kL slimline tanks 50% AEP 0.016 0.014 -0.002 -13% Total Area 2.31 m² 0.2 EY 0.024 0.021 -0.003 -13% Low flow orifice 50 mm 10% AEP 0.031 0.027 -0.004 -13% 35 mm/tank 5% AEP 0.035 0.033 -0.002 -6% Overflow 100 mm 2% AEP 0.041 0.040 -0.001 -2% Tank Height 1.86 m 1% AEP 0.046 0.044 -0.002 -4% Overlow height 1.76 m