Appendix E_Geotechnical Investigation
Attached to the e-mail MCU15/0109 Geotech and Bushfire Hazard reports - Links Drive Noosa Heads.
PROPOSED UNIT DEVELOPMENT
PRECINCTS E2 & F, NOOSA SPRINGS
7.5 Drainage
Adequate site drainage must be installed to ensure that surface water runoff is directed away from building
footings and walls. This could be achieved by constructing swales around structures, together with grated
channel drains along pathways and along/across access corridors. Surface diversion drainage should be
constructed up slope of building areas and along the crest of any new cut embankment (e.g. grassed or
landscaped swales or diversion mounds).
Subsurface drainage must be installed behind any retaining walls in order to prevent the development of
hydrostatic pressure (e.g. slotted ‘aggi’ pipe wrapped in filter ‘sock’ placed in gravel backfill).
All collected waters (including overflow from any rainwater tanks) must be directed by pipes or lined channels
to the legal point of downstream discharge.
Subsurface disposal of stormwater must not be undertaken (including infiltration pits).
8.0 LIMITATIONS
Your attention is drawn to the document “Report Limitations”, which is included in Appendix C of this report.
The statements presented in this document are intended to advise you of what your realistic expectations of
this report should be, and to present you with recommendations on how to minimise the risks associated with
the services provided by Tectonic for this project.
11 November 2015
Report No. 15193-002-Rev0 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.