Skip to the record
Search everything, all in one place.

Council archive · source document

51994.1248.01 Compiled APPROVED PLANS

of 8

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
           -
    NOOSA COUNCIL
   APPROVED PLANS
51994.1248.01 5 DEC 2014


[OCR of page images]
 

SUNSEEKER CLOSE

 

     
 

1/15 sunseeker close, noosaville

   
  

| EXISTING |
| RESIDENCE

STORMWATER EASEMENT

 

t
I
| c
| !
| |
|
i :
' : a
Los ‘h
i

 

 

NOOSA COUNCIL
APPROVED PLANS
51994.1248.01 5 DEC 2014

 

NOTES:

1, ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE,

2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL,

3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM

JOINT GROUP J2,
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4,

 

 

  
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF,
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH

AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.

8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
8. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS

AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY-ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL. BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
17, ALL TRADES ARE TO CONFORM WITH TNE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK

12, TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIENT: LESLIE & TONY | BUILDER:PAUL ROBERTS, MANDY'S DESIGN & DRAFTING

¢
i
&
“SHEET: 1of 3 |DATE: | IssuENo;
| SCALE: NOV14 BB aoe
, GH

 

 

__PROPOSED: i
DECK BUILD IN | PH: 0419 76 560

NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
RESPONSIBILITY IES THERE WITH

WITH ENGINEERS DRAWINGS

 

 

PH: 0409 278 879

| PH: 0403 484 474

 

Used in these records

About this file

File size
976 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

51994.1248.01 Compiled APPROVED PLANS.pdf · 976 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.