NOTES;
1, ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
N OOSA c Oo U N Cl L DOMESTIC BUILDING CODE,
APPR OV ED PLA NS 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
3, PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
51 994.1 248.01 5 DEC 201 4 4,HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5, TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
§. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
AS 1684,22010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9, BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN APTER CONSTRUCTION HAS COMMENCED
14, ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HiS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3860. 1.2000
UPPER FLOOR TOPPLATE§
UPPER FLOOR JOINERY LINE
UPPER FLOOR
“GROUND FLOOR TOP PLATE . _
GROUND FLOOR JOINERY LINE
GROUND FLOOR
"PAD LEVEL
1/15 sunseeker close, noosaville
elevation A
co RAFTERS TO ENGINEERS DESIGN
i
| f ~~~ ROOF PITCH ALIKE UNIT A
I
whe ed
4 S 8 z
| . 8) § ‘om 5
4 EXISTING RESIDENCE . | PROPOSED DEGK BUILD IN e ~~ _ 3
P / - : ~ ~ ns BLOCK BASE BUILD UP, SLAB, FOOTINGS +
Section 4 -ROOFINGTO ENGINEERS DESIGN
+ COLORBOND SHEET ROOFING ec
<—— TIMBER POST oO
ie oe : Se : csccnceumcneainnamene = ea
elevation D ne = aa OOK - = meso
Section 2 SS
| &
PROPOSED: - CLIENT: LESLIE & TONY | BUILDER:PAUL ROBERTS| MANDY'S DESIGN & DRAFTING | SHEET: 30f3 DATE: SSUENO: >
DECK BUILD IN /PH: 0419 776 560 PH: 0409 278 879 _ PH: 0403 481 474 SCALE: NOVI4 1B &
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION : eb
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
51994.1248.01 Compiled APPROVED PLANSRelated documentApplication case desk ↗
About this file
- File size
- 976 KB (small file)
- File type
No other editions are linked here.