Skip to the record
Trusted by locals. Built for Noosa.

Council archive · source document

Attachment 6 - Acoustic Report (Updated) 20.08.2020 · OPW20/0145

of 28

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

                                                                                                        MATTHEW PALAVIDIS
                                                                                                        VICTOR FATTORETTO
                                                                                                        MATTHEW SHIELDS




                                                                                                              Noosa Civic


                                                                                  Noise Impact Assessment




BRISBANE                                                                                                    ABN 11 068 954 343
Level 1                                                                                                 www.acousticlogic.com.au
82 Arthur Street
FORTITUDE VALLEY QLD 4006
(07) 3211 5591

The information in this document is the property of Acoustic Logic Consultancy Pty Ltd 11 068 954 343 and shall be returned on
demand. It is issued on the condition that, except with our written permission, it must not be reproduced, copied or communicated
to any other party nor be used for any purpose other than that stated in particular enquiry, order or contract with which it is issued.

I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                                         1
Full text of the other 27 pages

Page 2

Project ID                                                20191414.2
Document Title                                            Noise Impact Assessment
Attention To                                              Stockwell Development Group Pty Ltd
                                                          Attn:Harrison Hurst


  Revision           Date           Document Reference            Prepared By   Checked By      Approved
                                                                                                   By

      0           24/07/2020      20191414.2/2407A/R0/OB                OB

      1           26/08/2020      20191414.2/2608A/R1/OB                OB                         TS

      2           27/08/2020      20191414.2/2708A/R2/OB                OB                        OB




I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                               2

Page 3

                                                                TABLE OF CONTENTS




1  INTRODUCTION.................................................................................................................. 4
2  SITE DESCRIPTION.............................................................................................................. 5
3  NOISE TARGETS .................................................................................................................. 6
4  NOISE MEASUREMENTS..................................................................................................... 7
 4.1    MEASUREMENT LOCATIONS ...................................................................................... 7
 4.2    MEASURED NOISE LEVELS .......................................................................................... 8
   4.2.1    Unattended Measurements Results .............................................................................................. 8
   4.2.2    Attended Measurement Results...................................................................................................... 9
5 NOISE SOURCES/IMPACTS............................................................................................... 10
 5.1    LOADING DOCKS ....................................................................................................... 10
   5.1.1    Trolley Collection ................................................................................................................................10
   5.1.2    Delivery Trucks.....................................................................................................................................10
   5.1.3    Mechanical Plant .................................................................................................................................10
   5.1.4    Compactor.............................................................................................................................................10
 5.2    NOISE CALCULATION ................................................................................................ 10
6 RECOMMENDATIONS ...................................................................................................... 25
 6.1    MANAGEMENT CONTROLS ...................................................................................... 25
 6.2    ACOUSTIC BARRIER................................................................................................... 25
 6.3    RESIDENTIAL BUILDINGS FAÇADE CONSTRUCTION ............................................... 26
 6.4    MECHANICAL PLANT NOISE LEVELS ........................................................................ 27
7 CONCLUSION.................................................................................................................... 28




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                                                                   3

Page 4

1    INTRODUCTION

Acoustic Logic consultancy (ALC) have been engaged to conduct an assessment of major noise source
impacts from the Noosa Civic Shopping Centre onto proposed adjacent residential development.

The report is in response to the Council’s request:

    1.   Prepare and submit to Council for approval with and Operational Works application a revised acoustic
         report which includes measures to mitigate noise generated from the shopping centre operations and
         equipment, including deliveries, truck movements and rubbish collection. This report should consider
         attenuation at the noise source as well as a noise barrier along the shared boundary of Lots 19 and
         21. All measures to mitigate noise must be implemented prior the submission of the subdivision plan
         to Council.
         Noise attenuation is required to achieve the following acoustic quality for potential residential uses on
         Lots 17-19. The measurement location must include receivers being places at the closest point to the
         future residential and office buildings.


                                                                   Criteria (measured at the receptor) dB(A)
             Sensitive receptor             Time of Day
                                                                    LAeq,adj,1hr 1         LA1,adj,1hr2


                                       Daytime and evening
                                                                           35                    45
                                        (habitable spaces)
             Dwelling (indoors)
                                        Night-time (sleeping
                                                                           30                    40
                                               areas)

         1
         Acoustic descriptor/noise target for continuous noise sources (eg. Mechanical plant).
         2
         Acoustic descriptor/noise target for transient impacts arising from loading dock activities (e.g. truck
         movements, reversing alarms, compactor, trolley etc.)



The purpose of this assessment is the following:

    •    Establish the predicted intrusive noise levels at the proposed subdivision site on Hofmann Road for
         lots 17-21.
    •    Provide acoustic attenuation recommendations to meet the indoor acoustic criteria set by Noosa
         Shire Council. These are applied at the source, boundary and receiver.

This report includes attended and unattended noise measurements from the previous ALC acoustic report
(ref: 20191414.1/1501A/R2/SS, dated 15/01/2020).




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                  4

Page 5

2    SITE DESCRIPTION

The site comprising the proposed lots 17, 18, 19, and 21 is bound by the following:

        •    North, North-east - Noosa Civic Shopping Precinct
        •    West – Commercial precinct
        •    South - Townhouses across Hofmann Drive.

The loading docks are indicated in Figure 1 below.




                   LD 1
                   Woolworths
                                      LD 2




                   W

                                                         LD 3
                                                         Big W




                                                                                  Site (Lots 17,18,19,21)


                                                                                Noosa Civic Loading Docks




                                             Figure 1 – Site Location




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                               5

Page 6

3       NOISE TARGETS

In accordance to the Information Request, Noosa Shire Council has requested that the development be
assessed in accordance with the criteria below.

      Table 1 – EPP Noise 2008, Schedule 1 - Acoustic Quality Objectives for Residential

         Sensitive                  Time of Day                  Criteria (measured at the receptor)
         receptor                                                              dB(A)

                                                                 LAeq,adj,1hr1        LA1,adj,1hr2

                                 daytime and evening                  35                  45
     dwelling (indoors)           (habitable spaces)
                              night-time (sleeping areas)             30                  40
1
 Acoustic descriptor/noise target for continuous noise sources (e.g. mechanical plant).
2
 Acoustic descriptor/noise target for transient impacts arising from loading dock activities (e.g. truck
movements, reversing alarms, compactor, trolley etc.).




    I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                       6

Page 7

4     NOISE MEASUREMENTS

Measured noise levels are obtained from the previous ALC acoustic report (ref: 20191414.1/1501A/R2/SS,
dated 15/01/2020) and are presented below.

4.1   MEASUREMENT LOCATIONS

Monitor locations were selected upon accessibility and accuracy in considering ambient conditions whilst
capturing dominant noise sources around site.




                                                                Mech. plant deck
                       Exhaust/ Mech. plant



                                               3

                                    NGARA
        6

                                4


                                                                               2     1


                                                                                   RION NL 42




                                                            5



                                                                                                N



                                              Unattended              Attended

                                         Figure 2- Noise Measurement Locations




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                        7

Page 8

4.2 MEASURED NOISE LEVELS

 

 

 

 

 

 

 

 

 

 

 

 

4.2.1 Unattended Measurements Results
Table 2 -NGARA Measurement Summary
Date Average Acoustic Descriptor, dB(A)
leq Loo Lio Li

D* E* N* D* E* N* D* E* N* | D* E* N*
20/11/19 59 48 48 57 45 42 60 50 50 61 53 53
21/11/19 57 52 50 55 50 45 59 54 51 61 56 54
22/11/19 58 48 48 56 44 43 59 50 49 61 53 53
23/11/19 58 52 48 56 46 43 59 54 49 60 56 53
24/11/19 58 45 49 56 42 43 59 46 50 60 48 54
25/11/19 59 49 50 57 45 46 60 50 51 62 53 54
26/11/19 59 48 48 57 46 44 60 50 50 62 52 54
27/11/19 59 57 61 63
AVERAGE 58 49 49 56 45 44 60 50 50 | 61 53 54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00)

I:\Jobs\2019\20191414\20191414.2\202008270BA_R2_Noise_Impact_Assessment.docx

 

Page 9

Table 3 -Rion NL42 Measurement Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date Average Acoustic Descriptor, dB(A)
Leq Loo Lio Li

De) e& | N* | D* | BE | N* | D* |] E* | N* ] D* | EF | Ne
20/11/19 54 48 44 51 46 37 56 50 | 46 66 56 59
21/11/19 52 49 44 49 46 36 53 50 | 46 66 59 61
22/11/19 52 49 44 49 46 36 53 50 | 45 66 60 61
23/11/19 52 48 44 49 46 35 54 | 49 | 46 66 58 60
24/11/19 53 48 43 49 45 36 56 50 | 45 67 58 61
25/11/19 52 49 43 49 46 37 54 51 45 66 61 61
26/11/19 57 51 44 52 47 37 59 54 | 46 70 59 60
27/11/19 54 51 56 67
AVERAGE 53 49 44 50 46 36 55 51 46 | 67 | 59 | 60

 

* D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00)

4.2.2 Attended Measurement Results

Table 4 -Loading Dock Activity, Attended Measurements

 

 

 

 

 

 

Location’ Noise Source Acoustic Descriptor, dB(A)
Leq Linax Lpeak
1 Mechanical plant @ 25 57 62 78
metres
2 Reversing signal from trolley 69 76 83
collection truck
3 Mechanical plant noise 71 73 85

 

through exhaust/grille @ 1
metre away

 

 

 

 

' Refer to Figure 2 for location on map.

I:\Jobs\2019\20191414\20191414.2\202008270BA_R2_Noise_Impact_Assessment.docx

 

 

Page 10

5     NOISE SOURCES/IMPACTS

The following sections outline current major noise sources that were identified upon the previous site visit
to have potential impact on site.

5.1     LOADING DOCKS

5.1.1    Trolley Collection

During time on site, it was observed that trolley activity is a regular occurrence across both loading docks.
Noise level that was measured in relation to noise produced by trolley activity was 69 dB(A) L eq. Trolley
collections is understood to only occur during day and evening periods (i.e. 7am to 10pm) which is also
considered in this assessment.

5.1.2    Delivery Trucks

It was observed that small to medium sized delivery trucks were present within the loading docks during
time of site visit. We note that the loading dock operational hours as per installed signage start at 5AM
(based on Woolworths, unknown for others) and can run up to 10PM. No idling of trucks was assumed within
the sites (including the refrigeration trucks) and such restrictions should be included if not yet followed (e.g.
signs installed at the entry and along the boundaries of the shopping centre loading docks.

5.1.3    Mechanical Plant

The following mechanical plant was observed and noted in Figure 2.

         •   Eastern Loading Dock Plant deck above loading dock ‘5’ emitting a calculated sound power level
             of 93dB(A).
         •   Kitchen exhaust sound power level of 99dB(A).
         •   Western Loading Dock - Plant room/exhaust adjacent loading dock ‘2’ were measured and
             calculated to have a sound power level 90 dB(A).

Other plant is generally located on the rooftop of the shopping centre and therefore, providing significant
noise shielding. In any case, the assessment is based on a sound power level of 90dB(A)

At night, our predictions are based on kitchen exhaust fan being turned off together with other plant
adjacent to loading docks.

No other mechanical plant was considered and located during site inspections. In case of additional other
plant, these must operate to ensure that the L 90 background noise levels at the future residential buildings
are not exceeded.

5.1.4    Compactor

A compactor was noticed located by the ‘Big W’ loading dock 3 with an assumed Lmax sound power level of
100 dB(A). Compactor operation has been excluded from night time assessments as it should only operate
between the hours of 7am and 6pm.

5.2     NOISE CALCULATION

Measured noise levels and mechanical plant noise data and operational conditions highlighted in the
previous section have been used to calculate the predicted intrusive noise levels at the sensitive noise

 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                10

Page 11

receptors (lots 17, 18, 19, and 21) based on the expected building layouts of the Lots as described below
and indicated in the figures below.

A SoundPLANTM computer model was developed for these noise sources as described activities and used to
predict noise emissions from the compactor and loading docks to the sensitive receptors (lots 17, 18, 19,
and 21). Predictions were made for the following scenarios:

        •    All loading docks and compactor operating concurrently, representing the worst-case scenario
             for day time noise emissions.
        •    All loading docks operating concurrently, representing the worst-case scenario for evening and
             night time noise emissions.
        •    Only the compactor operating;
        •    Mechanical plant operational scenarios as described in this report.

The analysis was conducted based on the following assumptions:

        •    Mechanical plant decks indicated in Figure 2 have a sound power level of 90 dB(A) Leq each.
        •    Kitchen exhaust fan indicated in Figure 2 has a sound power level of 99dB(A) Leq;
        •    Loading dock trucks have a sound power level of 101 dB(A) L max. No idling of trucks was assumed
             within the sites (including the refrigeration trucks) and such restrictions should be included if
             not yet followed (e.g. signs installed at the entry and along the boundaries of the shopping
             centre loading docks.
        •    Compactor indicated in Figure 2 has a sound power level of 100dB(A) Lmax.
        •    Kitchen exhaust fans being turned off between 10pm and 7am and other plant adjacent and
             within loading docks not operational after 10pm and prior to 7am.
        •    Compactor is not operational between 6pm and 7am;
        •    No trolley collection between 10pm and 7am.
        •    The presence of a 6m wide plantation buffer between the northern boundary of the residential
             lots and the shopping centre paved loading dock and entry boundary.
        •    Façade line of proposed residential development approximately 8 metres from loading dock
             boundary (refer to the closest sensitive receiver buildings used in calculations indicated in figure
             below)




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                11

Page 12

       Assumed receiver
       building locations
       for Lots 17,18,19
       and 21.




          •
        •  Assessed habitable space taken as a typical bedroom with a floor area of 11m2, and volume of
           27m3.
        • Typical façade/glazing area of typical bedroom – 7.7m2, with the assumed typical layout
           presented below
        • Assessed typical living room with a floor area of 20m2, and volume of 50m3 with total façade
           glazing area 8m2, with the assumed typical layout presented below;
        • 1.8m high acoustic barrier along the boundary of lots 19, and 21 as indicated in Section 6.

Other configurations and activities/plant must be re-assessed during detailed design review of the
residential development to ensure that indoor noise limits can be achieved.




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                      12

Page 13

                                                           Glazing 2.1m x 1.5m
                                Glazing 3.0m x 0.5m                                       Glazing 3.0m x 0.5m




                                                                                                                Glazing 3.0m x 1.2m
          Glazing 3.0m x 1.2m                             Balcony          Balcony

                                    Bedroom                                                    Bedroom




                                         Living Room                                 Living Room




                                                Unit 1                                Unit 2




                                Façade Wall

                                Internal Partition Wall

                                                 Figure 3- Assumed Typical Unit Layout

Figure 4 to Figure 6 present the SoundPLANTM model of the day time period emissions for all loading docks
and the compactor operating concurrently. To assess compliance against the LA1,adj,1hr noise criteria for the
worst-case conditions, the model presents the Lmax dB(A) noise levels. The model includes the existing 1.0m
high wall in the loading area, as well as the proposed 1.8m high acoustic barrier along the boundary of the
sensitive receivers (lots 19, and 21 as indicated in Section 6).




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                                         13

Page 14

Figure 4- SoundPLANTM Day Time Modelling of All Loading Docks and Compactor – Ground Level




    Figure 5- SoundPLANTM Day Time Modelling of All Loading Docks and Compactor – Level 1




I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                14

Page 15

    Figure 6- SoundPLANTM Day Time Modelling of All Loading Docks and Compactor – Level 2




I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                15

Page 16

Figure 7 to Figure 9 present the SoundPLANTM model of the evening/night time period emissions for all
loading docks operating (note: loading dock not operational after 10pm and before 5am and no idling of
any truck allowed, incl. refrigeration trucks).




   Figure 7- SoundPLANTM Evening/Night Time Modelling of Loading Docks Only – Ground Level




       Figure 8- SoundPLANTM Evening/Night Time Modelling of Loading Docks Only – Level 1




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                     16

Page 17

       Figure 9- SoundPLANTM Evening/Night Time Modelling of Loading Docks Only – Level 2

Figure 10 to Figure 12 present the SoundPLANTM model of the day time period emissions for only the
compactor operating.




           Figure 10- SoundPLANTM Day Time Modelling of Compactor Only – Ground Level



 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                  17

Page 18

             Figure 11- SoundPLANTM Day Time Modelling of Compactor Only – Level 1




      Figure 12- SoundPLANTM Day and Evening Time Modelling of Compactor Only – Level 2


I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx              18

Page 19

Figure 13 and Figure 14 present the SoundPLANTM model mechanical plant day and evening time period
emissions.




  Figure 13- SoundPLANTM Day and Evening Time Modelling of Mechanical Plant – Lots 17 and 18




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                  19

Page 20

Figure 14- SoundPLANTM Day and Evening Time Modelling of Mechanical Plant – Lots 17, 18 and 19




      Figure 15- SoundPLANTM Day and Evening Time Modelling of Mechanical Plant – Lot 21




I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx               20

Page 21

Figure 16 to Figure 18 present the SoundPLANTM model mechanical plant night time period emissions (note:
kitchen exhaust and any mechanical plant adjacent to loading docks or any other major plant turned off).




         Figure 16- SoundPLANTM Night Time Modelling of Mechanical Plant – Ground Level




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                       21

Page 22

            Figure 17- SoundPLANTM Night Time Modelling of Mechanical Plant – Level 1




            Figure 18- SoundPLANTM Night Time Modelling of Mechanical Plant – Level 2


I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx            22

Page 23

Table 5 – Predicted Shopping Centre Noise Impacts at the Proposed Residential Lots

                                     Predicted Incident Noise Level                               Acoustic
      Receiver1          Time
                                            at Facade dB(A)                                      Treatment
                                                                                Internal
                                                   Compact.       Mech.
                                                                                                  Required
                                                                               Noise Level
                                                     LA12         Plant3                         to Achieve
                                     Loading                                    Criteria
                                                                   LAeq                            Indoor
                                     Dock, LA1                                   dB(A)
                                                                                                    Noise
                                                                                                    Limit4

                          Day            52            28           52          45 LA1,adj,1hr
    Lot 17 Ground       Evening                       N/A                      35 LAeq,adj,1hr
                                                                                                   Type A
         level                                                      41          40 LA1,adj,1hr
                          Night
                                                                               30 LAeq,adj,1hr

                          Day            57            28           56          45 LA1,adj,1hr     Type A
                        Evening                       N/A                      35 LAeq,adj,1hr
    Lot 17 Level 1
                                                                    45          40 LA1,adj,1hr
                          Night
                                                                               30 LAeq,adj,1hr

                          Day            60            29           57          45 LA1,adj,1hr     Type A
                        Evening                       N/A                      35 LAeq,adj,1hr
    Lot 17 Level 2
                                                                    48          40 LA1,adj,1hr
                          Night
                                                                               30 LAeq,adj,1hr

                          Day            46            37           51          45 LA1,adj,1hr    Acoustic
                                                                               35 LAeq,adj,1hr    Seals to
                        Evening                       N/A
    Lot 18 Ground                                                                                 windows,
         level                                                      43                           Non glazed
                                                                                40 LA1,adj,1hr
                          Night                                                                  wall to Type
                                                                               30 LAeq,adj,1hr
                                                                                                       A

                          Day            47            37           57          45 LA1,adj,1hr
                        Evening                       N/A                      35 LAeq,adj,1hr
    Lot 18 Level 1                                                                                 Type A
                                                                    45          40 LA1,adj,1hr
                          Night
                                                                               30 LAeq,adj,1hr

                          Day            47            41           57          45 LA1,adj,1hr
                        Evening                       N/A                      35 LAeq,adj,1hr
    Lot 18 Level 2                                                                                 Type A
                                                                    46          40 LA1,adj,1hr
                          Night
                                                                               30 LAeq,adj,1hr

                          Day            52            55           53          45 LA1,adj,1hr     Type A

    Lot 19 Ground       Evening                       N/A                      35 LAeq,adj,1hr
         level
                                                                    39          40 LA1,adj,1hr
                          Night
                                                                               30 LAeq,adj,1hr

    Lot 19 Level 1        Day            61            63           56          45 LA1,adj,1hr     Type B


I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                    23

Page 24

                                         Predicted Incident Noise Level                               Acoustic
          Receiver1          Time
                                                at Facade dB(A)                                      Treatment
                                                                                    Internal
                                                       Compact.       Mech.
                                                                                                      Required
                                                                                   Noise Level
                                                         LA12         Plant3                         to Achieve
                                         Loading                                    Criteria
                                                                       LAeq                            Indoor
                                         Dock, LA1                                   dB(A)
                                                                                                        Noise
                                                                                                        Limit4

                            Evening                       N/A                      35 LAeq,adj,1hr

                                                                        44          40 LA1,adj,1hr
                              Night
                                                                                   30 LAeq,adj,1hr

                              Day            62            63           56          45 LA1,adj,1hr     Type B
                            Evening                       N/A                      35 LAeq,adj,1hr
        Lot 19 Level 2
                                                                        45          40 LA1,adj,1hr
                              Night
                                                                                   30 LAeq,adj,1hr

                              Day            66            64           58          45 LA1,adj,1hr
        Lot 21 Ground       Evening                       N/A                      35 LAeq,adj,1hr
                                                                                                       Type B
             level
                                                                        38          40 LA1,adj,1hr
                              Night
                                                                                   30 LAeq,adj,1hr

                              Day            70            69           61          45 LA1,adj,1hr
                            Evening                       N/A                      35 LAeq,adj,1hr
         Lot 21 level 1                                                                                Type C
                                                                        45          40 LA1,adj,1hr
                              Night
                                                                                   30 LAeq,adj,1hr

                              Day            70            69           62          45 LA1,adj,1hr
                            Evening                       N/A                      35 LAeq,adj,1hr
         Lot 21 level 2                                                                                Type C
                                                                        47          40 LA1,adj,1hr
                              Night
                                                                                   30 LAeq,adj,1hr
1
    Refer to Figure 2 for location on map

2
 Compactor and associated plant only operational between 7am and 6pm. On that basis, at other times
noise impact is N/A – not applicable

3
    Exhaust fan and other plant adjacent to loading docks only operational between 7am and 10pm.

4
  Based on most exposed rooms and building locations as per Figure 4 The rooms assume typical bedroom
and living room dimensions with bedroom glazed façade area of 7.4m2. Subject to final room and building
layouts and the shielding offered by other buildings, the façade acoustic treatment requirements may differ
and would need to be reviewed after plans are finalised.




    I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                  24

Page 25

6     RECOMMENDATIONS

6.1     MANAGEMENT CONTROLS

It is recommended that operation of the compactor to be limited to the day time period only (7am – 6pm)
and not use kitchen exhaust and other mechanical plant adjacent to the loading docks between 10pm and
7am.

Furthermore, trolley collection must not occur after 10pm and prior to 7am.

Loading dock operation between 5am and 10pm has been considered, however, no idling of trucks should
occur within the sites at any time (including the refrigeration trucks) and such restrictions should be included
if not yet followed (e.g. signs installed at the entry and along the boundaries of the shopping centre loading
docks).

6.2     ACOUSTIC BARRIER

An acoustic barrier is recommended along the northern boundary of lots 21 and 19 adjacent to the
blockwork loading dock wall as shown in Figure 19. The height of the barrier must be a minimum of 1.8
metres above the loading dock ground level or top of the existing loading dock blockwork wall whichever
is higher, with a minimum surface density of 12 kg/m2. This assumes that the pad heights of the residential
buildings do not exceed that of the loading dock concrete pad level.

                                          Figure 19- Acoustic Barrier




      Acoustic barrier 1.8m high above loading dock ground level or top of loading dock blockwork wall,
                                             whichever is higher


 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                               25

Page 26

6.3   RESIDENTIAL BUILDINGS FAÇADE CONSTRUCTION

In addition to the management controls, to achieve the indoor noise levels within the considered habitable
areas (refer to Section 5.2), the following minimum façade construction is proposed. Refer to Table 5 for
specific locations where each Façade Type applies.

                         Table 6 – Façade Construction Recommendations

        Type                       Glazing Systems                                Façade Wall

           A           Nominal openable glazing system - Rw33            Masonry construction or Cladded
                      nominally with 6.38mm lam glass and seals          façade (9mm fibre cement sheet)
                                                                          on 90mm timber studs - cavity
                                                                             insulation (e.g. 75mm thick
                                                                         11kg/m3 glasswool) – min 10mm
                                                                            thick plasterboard internally
           B           Nominal openable glazing system - Rw35            Masonry construction or Cladded
                        nominally with 10.38mm lam glass and             façade (9mm fibre cement sheet)
                                    acoustic seals                        on 90mm timber studs - cavity
                                                                            insulation (e.g. 75mm thick
                                                                         11kg/m3 glasswool) – min 13mm
                                                                             thick Fyrchek plasterboard
                                                                                      internally
           C           Nominal openable glazing system - Rw37            Masonry construction or Cladded
                        nominally with 10.76mm lam glass and              façade (9mm fibre cement sheet)
                                    acoustic seals                         on 90mm timber studs - cavity
                                                                             insulation (e.g. 75mm thick
                                                                         11kg/m3 glasswool) – min 2 layers
                                                                               of 13mm thick Fyrchek
                                                                               plasterboard internally


In the case where any of the apartments/habitable areas are elevated with the floor exposed to noise from
the shopping centre, the floor is assumed to be of concrete construction (nominally 150mm thick). Other
construction details may be acceptable but must be reviewed and approved by an acoustic consultant in
order to achieve indoor noise levels of finalised building layouts.

The minimum roof construction must be of concrete or alternative colorbond with Anticon 145 and
plasterboard ceiling with 75mm thick glasswool (11kg/m3) overlay.

Where building layouts and locations or habitable areas differ from what has been considered, additional
assessment is required.

Buildings located further from the loading docks in comparison to the ones considered in this report must
be constructed based on Type A construction as a minimum.




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                26

Page 27

6.4   MECHANICAL PLANT NOISE LEVELS

In order to achieve compliance with the continuous noise criteria outlined in Table 1, the operational
conditions must follow the recommendations in Section 5.




                       Exhaust/ Mech. plant    A                   Mech. plant deck   C


                            Mech Plant Adjacent
                            to Loading Docks




                                                                            B


                                                                                          Mech Plant Adjacent
                                                                                          to Loading Docks




                                                                                                                N



                                              Figure 20- Mechanical Plant Locations




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                                       27

Page 28

7    CONCLUSION

ALC have conducted a noise impact assessment of the loading dock activities and mechanical plant located
at Noosa Civic Shopping Centre, 28 Eenie Creek Road, Noosaville. The purpose of the assessment was to
determine the predicted intrusive noise levels at the proposed subdivision site on Hofmann Road for lots
17, 18, 19, and 21. Previous noise monitoring data conducted by ALC (ref: 20191414.1/1501A/R2/SS, dated
15/01/2020) has assisted in establishing the acoustic environment associated to the subject site (Table 1 and
2).

Provided the recommendations in Section 6 are implemented, the development is predicted to achieve
compliance with the Noosa Shire Council assessment criteria.

We trust this information is satisfactory. Please contact us should you have any further queries.

Yours faithfully,




Acoustic Logic Consultancy Pty Ltd
Omar Busaidi




 I:\Jobs\2019\20191414\20191414.2\20200827OBA_R2_Noise_Impact_Assessment.docx                            28

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 6 - Acoustic Report (Updated) 20.08.2020.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.