Attachment 6 - Acoustic Report (Updated) 20.08.2020 · OPW20/0145
4.2 MEASURED NOISE LEVELS 4.2.1 Unattended Measurements Results Table 2 -NGARA Measurement Summary Date Average Acoustic Descriptor, dB(A) leq Loo Lio Li D* E* N* D* E* N* D* E* N* | D* E* N* 20/11/19 59 48 48 57 45 42 60 50 50 61 53 53 21/11/19 57 52 50 55 50 45 59 54 51 61 56 54 22/11/19 58 48 48 56 44 43 59 50 49 61 53 53 23/11/19 58 52 48 56 46 43 59 54 49 60 56 53 24/11/19 58 45 49 56 42 43 59 46 50 60 48 54 25/11/19 59 49 50 57 45 46 60 50 51 62 53 54 26/11/19 59 48 48 57 46 44 60 50 50 62 52 54 27/11/19 59 57 61 63 AVERAGE 58 49 49 56 45 44 60 50 50 | 61 53 54 * D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00) I:\Jobs\2019\20191414\20191414.2\202008270BA_R2_Noise_Impact_Assessment.docx