Council archive · source document
A - Proposal Plan · 51983.3225.16
Plans and drawings: the text below has words only, no drawings.
PROJECT: PROPOSED RESIDENTIAL ALTERATIONS ADDRESS: 3/30 HASTINGS STREET, NOOSA HEADS, QLD 4567 STAGE: DEVELOPMENT APPLICATION www.gtgroup.net.au GT € R oe 6 S [email protected] 0410 063 172 (07) 3298 6938
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 10 pages
Page 2
NOOSA HEADS MAIN BEACH
BAY VILLAGE SHOPPING CENTRE
SUBJECT SITE. LOT 3
THE HASTINGS. REFER
SITE PLAN BELOW
THE SEBEL
WEYBA CREEK
"mE
. .
)PPING CENTRE
7
| ‘
EXISTING A 'SEBEL' BUILDING
——_
SITE DATA
RPD
LOTIPLAN: 3/GTP1154
PARISH OF WEYBA
COUNTY OF MARCH
LOCAL GOVERNMENT; NOOSA SHIRE COUNCIL
LOCALITY: NOOSA HEADS
SEGMENT/PARCEL: 30824/41
OVERALL SITE AREA: 4932 SQM
SUBJECT SITE AREA: 96 SQM
SITE PLAN
SCALE 1:500
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION.
4. DO NOT SCALE THIS DRAWING.
COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
| clcna seer ze 8¥a02=7—") | | OCALITY AND SITE PLAN
NOTES: AMENDMENTS PROJECT
1, THIS IS A COMPUTER GENERATED DRAWING, DONOTAMENDBYHAND.| Rey DATE DESCRIPTION By - -DAISSUE
2 TETOUTS ARE TO BE CHECKED ONSITE PROR TO CONSTRUCTON, ‘A ]26.08.2022] ISSUE FOR DEVELOPMENT APPROVAL GB PROPOSED RESIDENTIAL ALTERATIONS
‘ADDRESS
> 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567
| AUTHOR: GB DRAWING
DRAWING GREATED ‘SCALE @AB
AUG 2022 1:500
PROJECT NO. REVISION
www.gtgroup.net.au
21021 A ( al G R © lg Pp [email protected]
DWG. NO. 0410 063 172
DAO01 (07) 3298 6938
Page 3
LEGEND NOTE NOTES NOTE:
COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
f- “
ADJOINING PROPERTY NOTE: DEMOLITION NOTES
(SHOPPING CENTRE) ROOM DIMENSIONS 1. DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
/ é \ 2. DEMOLISH EXISTING DOORS AND WINDOWS.
_ _ 60 SHOWN ARE TO 3. DEMOLISH EXISTING STAIRS AND HANDRAIL.
- Bo FINISHED WALL FACES. 4. DEMOLISH EXISTING CONCRETE GROUND SLAB.
a = SNDARY 5. DEMOLISH EXISTING SCREEN STRUCTURES.
ING 2M HigH BLOCK; ~—— 6. DEMOLISH EXISTING BRACING FRAMES, NOTE:
K WALL -—» CONFIRM SUFFICIENT RECTIFICATION WITH
STRUCTURAL ENGINEER TO SUIT NEW WORKS.
WC 7. DEMOLISH EXISTING GROUND PAVERS TO
A EXTENT SHOWN.
| 1625x860mm 8. DEMOLISH EXISTING JOINERY BENCH.
7 VINYL 9. REMOVE EXISTING TUB, EQUIPMENT AND
J. NOTE 19 CUPBOARDS AND RETAIN FOR REINSTATEMENT
COL (CLIENT TO CONFIRM).
NOTE 5 NOTES
| far NOE COL ~ NOTE 1 (EXTG,) Nove 1.NOTE2 ae 10. DEMOLISH EXISTING HOT WATER SYSTEM AND
4 ngTe 171/COW_ INOTE6 |e | : O NOTE 17 NOTE 17 te@y __ NOTE 17 ASSOCIATED WORKS.
[(EXTG) | | EXT) ( <7 | == Aare 11. DEMOLISH EXISTING VINYL FLOORING.
jpop yep : NOTE! I IKITCHEN! 7 Sl NOTE > 12. DEMOLISH EXISTING SANITARY FIXTURES
s hoyoh ) p lbe DRYwIIE = — lo 53 qo Ul 5 INCLUDING TOILETS, SHOWERS AND BASINS.
y z be ee EY AUINEIN YE) Le “Srsletoomgt LT) iu 2 13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
ay let the ommel 5uib |S [NOTE44 5S;
Bboy ih Vg [oB645y2200min: = I}, 2 — |S S ___vinyL || SSN EXISTING EQUIPMENT FOR REINSTATEMENT
3 to pelt Ui | i eonéretress | r— yl 3 i, NOTE Tinbtk feR 7 (CLIENT TO CONFIRM).
a WU yy | = NOTEA 5 ky — — i |= 6 | A ACH HH He 14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
b> ea ‘SCO NOTE co =H HH HHH SUFFICIENT RECTIFICATION WITH STRUCTURAL
NOTE 1 | ~ NOTE 11 ~
tL Fae roa (exTG) | |_| ADJOINING Py ww ENGINEER TO SUIT NEW WORKS.
(| FbapsstomM I | ahi ui iL 8 15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
| Lo {PPAVERS_ 4 NOTE T | t+ VILLA LPL) PEF Ly e4goxpas MOUNTING BRACKETS
foi oy dh | Ly Peay LPL LI a 46. DEMOLISH EXISTING TELEVISION.
| Hos Mee Setestet 0 | \ | rit rl ik MINYLI ne 47, DEMOLISH EXISTING DOWNPIPE,
col yy in COL col | JU UU YY 2 18. DEMOLISH EXISTING DECKING TO EXTENT
Li (EXTG,) Ea Li SHOWN.
W 49. DEMOLISH EXISTING DECK BALUSTRADE.
\ AS
l ‘lo
wu ll
| Sill
o— -_ —
SSE
NOTE 19
® BOUNDARY
on oO !
ox \ |
(02 \ DEMOLITION PLAN - LEVEL 1
S 9 a, SCALE 1:100
N
VILLA | ! ADJOINING aN
| | VILLA
(01. \ DEMOLITION PLAN - GROUND
YT) SCALE 1:100
NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @AB
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY DA ISSUE
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2022 14
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TOCoNSTRUCTION | A ]26.08.2022] ISSUE FOR DEVELOPMENT APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 20220 00
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ADDRESS PROJECT NO. REVISION Ramer ei ear sl
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION & le
4. BOWoT SCALE TS DRAWING 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 Ar G | ( i R @ [ Pp meric ues
COPYRIGHT: [ AUTHOR: 6B DRAWING DWG. No. eS AY es
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
(07) 3298 6938
| ORIGINAL SHEET SIZE: A3 (420x207mm]
DEMOLITION PLAN - GROUND AND LEVEL 1 DA002
Page 4
LEGEND NOTE NOTES NOTE:
COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
NOTE: [DEMOLITION NOTES. |
ROOM D | M ENS IONS DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
AN, sHown are 0 See aerate
FINISHED WALL FACES.
DEMOLISH EXISTING CONCRETE GROUND SLAB.
DEMOLISH EXISTING SCREEN STRUCTURES.
DEMOLISH EXISTING BRACING FRAMES, NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
ENSUITE BATH WC STRUCTURAL ENGINEER TO SUIT NEW WORKS,
1965x1570mm — 1670x1570mm 1570x860mm 7. DEMOLISH EXISTING GROUND PAVERS TO
TILE TILE TILE EXTENT SHOWN.
8. DEMOLISH EXISTING JOINERY BENCH.
9, REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).
10. DEMOLISH EXISTING HOT WATER SYSTEM AND
NOTE 17 ASSOCIATED WORKS.
11, DEMOLISH EXISTING VINYL FLOORING.
12, DEMOLISH EXISTING SANITARY FIXTURES
INCLUDING TOILETS, SHOWERS AND BASINS.
13, DEMOLISH EXISTING KITCHEN JOINERY, RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).
_ DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
NOTE 24 SUFFICIENT RECTIFICATION WITH STRUCTURAL
ENGINEER TO SUIT NEW WORKS.
15, DEMOLISH EXISTING AIR CONDITIONER AND WALL
MOUNTING BRACKETS
16, DEMOLISH EXISTING TELEVISION.
17, DEMOLISH EXISTING DOWNPIPE,
18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.
49. DEMOLISH EXISTING DECK BALUSTRADE.
20, DEMOLISH EXISTING BEDROOM JOINERY.
EAVES LINE OVER 21. DEMOLISH EXISTING FLOOR TILES TO EXTENT
SHOWN.
22. DEMOLISH EXISTING CARPET FLOORING TO
EXTENT SHOWN.
23. DEMOLISH EXISTING ROOF SHEETING.
| 24. DEMOLISH EXISTING EAVES GUTTERS.
Parwn>
EAVES|LINE OVER
il
ly
o
LATICTTUATNATT ATTN TTA TTA TTT TTT TTT TT TTT
2
z
NOTE 17
note wis
| tol
| O|INOTE
=>LX24
NOTE 24
1211 3655x3170mm “| 3225x2660mm: iE
£ CARPET | 2
NOTE 22
ee CARPET =
It NOTE 22°. |
igh.
NOTE 1NOTE2 NOTE1 NOTE1 NOTE2
NOTE 20
(UIVLLUIULI LVL LUT LULL LVL
|
|
|
| |p. .
|
Ht BED 1 NOTE 16]
|
|
|
|
|
!
|
|
|
|
|
|
|
|
L
Im
Il
(03 \ DEMOLITION PLAN - LEVEL 2 (04 \ DEMOLITION PLAN - ROOF
YT) SCALE 1:100 YT SCALE 1:100
NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @AS
2. THSORAMING SHOMSDESIGN NTENT OMY ALCONENSIONS nD. | EV _ATE__DESORETON ey DA ISSUE OPO 0 AUG 2022 1:100
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. | A |26.08.2022] ISSUE FOR DEVELOPMENT APPROVAL CB PROPOSED RESIDENTIAL ALTERATIONS AUG 2022001:
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ADDRESS PROJECT NO. REVISION Ramer ei ear sl
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. . i. .
4. BOWoT SCALE TS DRAWING 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 Ar G | ( i R @ [ Pp meric ues
covynctr [a | sas owe. No pre
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297) DEMOLITION PLAN - LEVEL 2 AND ROOF DA003
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
(07) 3298 6938
Page 5
NOTE BUILT WORKS ARE TO REMAIN. FOR FURTHER CLARIFICATION ON EXTENT OF DEMOLITION NOTES UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN |S TO COMPLY WITH THE NATIONAL CONSTRUCTION CODE (BCA), RELEVANT NOTE: THESE DRAWINGS ARE DESIGN CONCEPTS ONLY AND SHALL NOT BE USED IN ANY WAY FOR STRUCTURAL PURPOSES. REFER TO STRUCTURAL ENGINEER'S DETAILS WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL REQUIREMENTS. 2, ALL SETBACK/SETOUT DIMENSIONS ARE TO BE CHECKED AND VERIFIED ON SITE PRIOR TO CONSTRUCTION. ADJOINING PROPERTY NOTE: (SHOPPING CENTRE) ROOM DIMENSIONS SHOWN ARE TO —— a Ferg 2 UNDA FINISHED WALL FACES. ING TTC cr, ROOF BELOW DPx3 STORE AT su ~9 th dy it WN q DPR sales LEGEND GARDE g TOR AW AWNING WINDOW a l 7 3800x2500mm © 200K3| = = COL STEEL COLUMN a = 2 CT COOKTOP COE NS re 3 x DHW DOUBLE HUNG WINDOW GAL ext.) CGE IS s DP DOWNPIPE (EXC To COL DRY CLOTHES DRYER errs) (EXTG) | FW FLOOR WASTE pet hy DW DISHWASHER . | | \ i , HALLWAY FGW FIXED GLASS WINDOW % SS)! TOR 2% 4815x905mm HB HAND BASIN 8 JARPORTI> = 4354 S Tile LVW LOUVRE WINDOW 5 NS 425x2200mm 3 3 8085%3290mm 1S LE LS 2 OV OVEN g 2 a. 48 = P PANTRY 3 2 REF REFRIGERATOR 5 SGD SLIDING GLASS DOOR _ = ADJOINING S SGW SLIDING GLASS WINDOW WMORV HS SHR SHOWER I EF ew CH g VILLA SWP SANITARY WASTE PIPE 1——+— BATH/ Wc TOILET coL WM WASHING MACHINE Lg] ~Shexte) | LAUNDRY TAIRSIUP J 2200x1700mm DOOR (REINSTATED) =[fg 2 z | ENCLOSE 2 TILE = DECK ilka NS] /STAIRWEL Sie B 9 $3 |b a 2 € Sih oa z 3525x2110mm SES Ve TIMBER wn 1 _ HANDRAIL ROOF BELOW BOUNDARY I O° N | (02 \ PROPOSED PLAN - LEVEL 1 9° a, SCALE 1:100 \ ADJOINING ; ‘a VILLA | ADJOINING VILLA (01 \ PROPOSED PLAN - GROUND YT) SCALE 1:100 wores: ‘AMENDMENTS PROLECT TRAINGCREAED «SMEG 1. THIS IS A COMPUTER GENERATED DRAWING, DO NOTAMENDBYHAND.| pey DATE DESCRIPTION By ° 7 eam seston wen on Auonetoms | SS eae ox IOAN ROTA DA ISSUE PROPOSED RESIDENTIAL ALTERATIONS Aue 2022 +100 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ADDRESS PROJECT NO. REVISION Ramer ei ear sl 4 OONTSCAETISORAING 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 Bet A GT ( i R @ lg P DCR et eee copvaic: [Ramo ce oRAWNG D6 No, eae THE LAWS OF COBVRIGHT AND HAY NOT BE CODIED OR REPRODUCED. | ORIGINAL SHEET SIZE: A3 (420x297) PROPOSED PLAN - GROUND AND LEVEL 1 DA004 Oe WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
Page 6
NOTE NOTES
NOTE:
LEGEND
THESE DRAWINGS ARE DESIGN CONCEPTS
AW AWNING WINDOW OF OVERFLOW UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN
COL STEEL COLUMN OV OVEN BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CT COOKTOP P PANTRY CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
DHW DOUBLE HUNG WINDOW REF REFRIGERATOR WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
DP DOWNPIPE SGD SLIDING GLASS DOOR PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
DRY CLOTHES DRYER SGW SLIDING GLASS WINDOW SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
FW FLOOR WASTE SHR SHOWER 2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
DW DISHWASHER SWP SANITARY WASTE PIPE TO BE CHECKED AND VERIFIED ON SITE
FGW_ FIXED GLASS WINDOW WC TOILET PRIOR TO CONSTRUCTION.
HB HAND BASIN WM WASHING MACHINE
LVW LOUVRE WINDOW
NOTE:
q ROOM DIMENSIONS
FINISHED WALL FACES.
PARAPET
b b
2 a OOF BELOW
& = ROOF BELOW Ri
|| (DP 300x175mm (MIN. BOX GUTTER & ?
a a DPx2
OF
=
2
ENSUITE -= = ENSUITE ENSUITE -=
3085x2170mm G QS 3140x2170mm 2450x2200mm
a a
TILE 5 3 TILE TILE
3530x1000mm
CARPET.
STORAGE
770
i
PARAPET
PARAPET
BED 1
4255x3225mm
21
VINYL PLANK
FAMILY ROOM
5 BED 2 || BREAKOUT a
z 4255x3170 2 6515x2956mm “|
5 mn 5 3440x3080mm CARPET
8 VINYL PLANK a CARPET
1
4
Zz
/
820 SCREENING
2112 LVW 3 12LVW) 21
8
DECK
3525x2440mm.
TIMBER
HANDRAIL
T U
NS
DECK BELOW Al
AW
04518 FGW.
SCREENING
04518- FGW
SCREENING
PARAPET
PARAPET
HANDRAIL
PARAPET
(05 \ PROPOSED PLAN - ROOFTOP
(03 \ PROPOSED PLAN - LEVEL 2
YT) SCALE 1:100
YT SCALE 1:100
((04.\ PROPOSED PLAN - LEVEL 3
YT) SCALE 1:100
NOTES: AMENDMENTS PROJECT “DRAWINGCREATED - SCALE@A3
Fi eacowenceiepouwme coverwepeywo| fey owe snore w DA ISSUE O50 0 nce
‘SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A | 26.08.2022 | ISSUE FOR DEVELOPMENT APPROVAL, PR P SED RESIDENTIAL ALTERATI NS :
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ‘ADDRESS PROIECTINO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 21021 A drake A “
4. DONOT SCALE THIS DRAWING 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 a [email protected]
Ser cROUP 8 |ILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY ! AUTHOR: 68, DRAWING EWG. NO. Ne Ae
ui [auTHoR: GB
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 420x297mm) PROPOSED PLAN - LEVEL 2, LEVEL 3 AND ROOFTOP DA005 ODETTE)
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
Page 7
15m HEIGHT LIMIT ROOFTOP (RL 13.885) av LEVEL 3 (RL 11.005) WZ LEVEL 2 (RL 8.125) ZW LEVEL 1 (RL 5.58) av GROUND (RL 2.70) WZ NGL (RL 1.98) (01 \ EASTERN ELEVATION YT SCALE 1:100 NOTE NOTES UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT THESE DRAWINGS ARE DESIGN CONCEPTS ONLY AND SHALL NOT BE USED IN ANY WAY FOR STRUCTURAL PURPOSES. REFER WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL 2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS. TO BE CHECKED AND VERIFIED ON SITE PRIOR TO CONSTRUCTION, 15m HEIGHT LIMIT ROOFTOP ARBOUR FRAME FEATURE VISUAL/PRIVACY SCREENING TO WINDOWS ROOFTOP (RL 13.885) ZZ LINEAR WALL CLADDING ALUMINIUM FRAMED GLAZED WINDOWS TYPICAL FEATURE BATTEN SCREENING TO STAIRWELL WINDOWS LEVEL 3 (RL 11.005) Z _— TEXTURED WALL CLADDING ALUMINIUM FRAMED GLAZED DOORS TYPICAL LEVEL 2 (RL 8.125) ZW BIFOLD DOOR (REINSTATED) STAINLESS STEEL WIRE BALUSTRADE TYPICAL LEVEL 1 (RL 5.58) Z _— PAINTED DOWNPIPES TYPICAL LINEAR WALL CLADDING GROUND (RL 2.70) Ww NGL (RL 1.98) (02\ NORTHERN ELEVATION YT SCALE 1:100 NOTES: 1, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BY HAND. 2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND ‘SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 4. DO NOT SCALE THIS DRAWING. COPYRIGHT: © GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. AMENDMENTS REV _DATE DESCRIPTION ‘A |26.08.2022] ISSUE FOR DEVELOPMENT APPROVAL = -DAISSUE GB | AUTHOR: GB [ORIGINAL SHEET SIZE: A3 [420:297mm] PROJECT “DRAWINGCREATED -- SCALE@A3 PROPOSED RESIDENTIAL ALTERATIONS AUG 2022 1:100 ADDRESS PROJECT NO. REVISION CEG STEUER 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 aor ak G R O U P diab tee DRAWING OWG. NO, (07) 3298 6938 EASTERN AND NORTHERN ELEVATIONS DA006
Page 8
15m HEIGHT LIMIT NOTE UNLESS NOTED OTHERWISE, ALL EXISTING BUILT WORKS ARE TO REMAIN. FOR FURTHER CLARIFICATION ON EXTENT OF DEMOLITION WORKS, REFER TO PROPOSED FLOOR PLAN FOR PROPOSED RECONFIGURATION LAYOUT, WALL SETOUT DIMENSIONS AND OPENING LOCATIONS. 15m HEIGHT LIMIT p]HoJ J ROOFTOP ARBOUR FRAME —— —__ FEATURE VISUAL/PRIVACY SCREENING TO WINDOWS ROOFTOP (RL 13.885) Z —_ ROOFTOP (RL 13.885) ZZ — € LINEAR WALL CLADDING LEVEL 3 (RL 11.005) Ww LEVEL 2 (RL 8.125) | Z — 7 Pe eh == LEVEL 1 (RL 5.58) Z —_ an GROUND (RL 2.70) WZ NGL (RL 1.98) (03 \ WESTERN ELEVATION YT SCALE 1:100 ALUMINIUM FRAMED GLAZED | | WINDOWS TYPICAL LEVEL 3 (RL 11.005) Ww TEXTURED WALL CLADDING LEVEL 2 (RL 8.125) WwW _ STAINLESS STEEL WIRE BALUSTRADE TYPICAL LEVEL 1 (RL 5.58) Z _— TYPICAL i ALUMINIUM FRAMED GLAZED DOORS TYPICAL LINEAR WALL CLADDING GROUND (RL 2.70) Wo | | PAINTED DOWNPIPES NGL (RL 1.98) NOTES 1. ALL CONSTRUCTION WORK UNDERTAKEN IS TO COMPLY WITH THE NATIONAL CONSTRUCTION CODE (BCA), RELEVANT AUSTRALIAN STANDARDS AND APPLICABLE LOCAL AUTHORITY REQUIREMENTS. 2. ALL SETBACK/SETOUT DIMENSIONS ARE TO BE CHECKED AND VERIFIED ON SITE PRIOR TO CONSTRUCTION, (04) SOUTHERN ELEVATION YT SCALE 1:100 NOTE: THESE DRAWINGS ARE DESIGN CONCEPTS ONLY AND SHALL NOT BE USED IN ANY WAY FOR STRUCTURAL PURPOSES. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL MEMBER SIZES, SPECIFICATIONS AND SITE SPECIFIC STRUCTURAL REQUIREMENTS, NOTES: AMENDMENTS 1, THIS IS A COMPUTER GENERATED DRAWING, DONOTAMENDBYHAND.| Rey DATE DESCRIPTION 2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND ‘SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A |26.08.2022) ISSUE FOR DEVELOPMENT APPROVAL 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS [ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 4. DO NOT SCALE THIS DRAWING. COPYRIGHT: © GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. s PROPOSED RESIDENTIAL ALTERATIONS AUG 2022 4-100 ADDRESS PROJECT NO. REVISION CEG STEUER 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 aor 5 R O U P Cree ess | AUTHOR: GB DRAWING DWG. NO. 0410 063 172 | oncha.sger Sze since | WESTERN AND SOUTHERN ELEVATIONS DA007 CDLEDCEE
Page 9
< aa
- FRONT ENTRY (SOUTH EAST
ite
PERSPECTIVE VIEW 1
I
sel)
PERSPECTIVE VIEW 3 - SIDE (SOUTH)
PERSPECTIVE VIEW 4 - SIDE (SOUTH WEST)
THs |S ACONPUTER GENERATED ORAWNG, DO NOT aueno ey Han, | AMENDMENTS
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND | —e¥_DATE __DESCRPTION
‘SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A 26.08.2022) ISSUE FOR DEVELOPMENT APPROVAL
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION,
4. DO NOT SCALE THIS DRAWING.
COPYRIGHT:
(© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
GB
DA ISSUE
[RuTion: Ge
| ORIGINAL SHEET SIZE: A3 [420x297mm]
PROJECT “DRAWINGCREATED -SCALE@ AS
PROPOSED RESIDENTIAL ALTERATIONS AUG 2022 14
‘ADDRESS PROJECT NO. REVISION
3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 21021
DRAWING DWG. NO.
PERSPECTIVE VIEWS 1 OF 3 DA008
www.gtgroup.net.qau
[email protected]
GT GROUP
(07) 3298 6938
Page 10
THs IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BY HAND, AMENDMENTS 2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND. | ~e¥_DATE_DESCRPTION SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 4. DO NOT SCALE THIS DRAWING. COPYRIGHT: ‘©GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. | AUTHOR: GB [ ORIGINAL SHEET SIZE: A3 (420:297mm) PROJECT PROPOSED RESIDENTIAL ALTERATIONS ADDRESS 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 DRAWING PERSPECTIVE VIEWS 2 OF 3 DRAWING CREATED ‘SCALE @A3 AUG 2022 11 PROJECT NO, REVISION 21021 A DWG, NO, DA009 GT GROUP www.gtgroup.net.au [email protected] PST (OD REE CKE)
Page 11
PERSPECTIVE VIEW 10 - STAIRWELL DETAIL PERSPECTIVE VIEW 11 - LEVEL 2 DECK PERSPECTIVE VIEW 12 - LEVEL 1 DECK THs IS ACOMPUTER GENERATED DRAWING, DO NOT AMEND BY HAND, AMENDMENTS 2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND. | -S¥_DATE_DESCRPTION SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A |26.08.2022| ISSUE FOR DEVELOPMENT APPROVAL 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS [ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, 4. DO NOT SCALE THIS DRAWING. COPYRIGHT: © GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. | ORIGINAL SHEET SIZE: A3 [(420x297mm] PERSPECTIVE VIEWS 3 OF 3 PROPOSED RESIDENTIAL ALTERATIONS AUG 2022 PROJECT NO, 3/30 HASTINGS STREET, NOOSA HEADS QLD 4567 21024 DWG, NO, DA010 www.gtgroup.net.qau [email protected] GT GROUP (07) 3298 6938
Used in these records
A - Proposal Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.1 MB (large file)
- File type
No other editions are linked here.
Original file