Original source · versioned page text
LATE RFI - Revised SWMP
S
97
96
89
8
93
97
91
90
92
96
S
97
S
94
TURNOUT DRAINAGE SWALE
THROUGH LEVEL SPREADER
SPILLWAY OF MINIMUM 4M
95
TYPICALLY AS PER IECA STD
DWG LS-01
S
S
MINIMUM 3KL RAINWATER REUSE
TANK TO BE PROVIDED FOR FUTURE
DWELLINGS ON NEW LOT. TANK TO PROVIDE TABLE DRAIN
BE CONNECTED FOR INTERNAL AND 300mm DEEP WITH 1V:2H
S
EXTERNAL NON-POTABLE REUSE BATTERS TO DIVERT
UPSTREAM RUN-OFF
97
UPSTREAM STORMWATER CATCHMENT
AREA: 0.25Ha
S
Fi: 31.0%
tc (FRIENDS EQN): 10 Min
Itc (1%): 235mm/hr
93
RATIONAL METHOD
S
1hr10: 65.2mm/hr
C10: 0.73
Fy: 1.2
CLIMATE FACTOR: 1.2
S
95
Qy = 1/360 * 0.25 * (1.2*0.73) * 235 *1.2
= 0.172m³/s
93
91
S
90
92
89
300mm 1V:2H
94
96
S
97
CHANNEL FLOW (MANNINGS EQN)
Sf: 4.4%
DEPTH: 0.30m
SIDE SLOPES: 1V:2h
S
BASE: 0m
WETTED PERIMETER: 1.34m
AREA: 0.18m²
HYDRAULIC RADIUS (A/P): 0.134m
MANNINGS n (GRASS): 0.035
S
CAUTION: SEWER LINE IN V: 1.57m/s
VICINITY. POTHOLE TO LOCATE FLOW CAPACITY (Qcap) = 0.283m²
AND ENSURE MINIMUM 600mm
COVER TO FINISHED SURFACE Qcap > Qmax = TRUE
S
98
98
S
S 98
S
S S
98
98
INDICATIVE NEW DRIVEWAY
92
LOCATION. FINAL DESIGN TO
BE CONFIRMED
93
95
95
94
97
90
96
91
98
90
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL SUBDIVISION
NEIL GAGHAN TITLE: STATUS:
35 PAVILION STREET STORMWATER LAYOUT FOR APPROVAL - NOT FOR
© ABN 89 647 469 707
02 26/05/23 RFI UPDATE BRP BRP
POMONA, 4568, QLD BEN PARRY PLAN CONSTRUCTION
75 NOOSA DRIVE RPEQ: 28084
01 30/09/22 MCU ISSUE BRP MVP BRP SCALE: 1:250
NOOSA HEADS, QLD 4567
5 15 25m CPEng NER DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
DATE: 26/05/2023 SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
040 20220206 A1 02