Noosa Council Plan July 2020
Performance and Acceptable Outcomes Table
Version: 2020
Performance Outcomes Acceptable Outcomes Solution1 Comments Council Use
PO16 AO16
On-site effluent treatment and disposal systems An onsite effluent system and disposal area
are designed, constructed and managed to not is:
compromise the environmental values of waters (a) not located on a slope greater than 1 in
and water quality objectives. (10%);
(b) not located at or below the 1% annual
exceedance probability (AEP flood
event);
(c) not located within a riparian buffer area
mapped on a Biodiversity, Waterways
and Wetlands Overlay Map; and
(d) setback 400 metres minimum from the
full supply level of Lake Macdonald.
Editor’s Note—The Plumbing and Drainage
Act 2003 sets out requirements for on-site
effluent treatment and disposal. The N/A
Queensland Plumbing and Wastewater Code
and associated
guidelines are used to confirm the suitability
of each site to accommodate an on-site
sewerage facility; or where a centrally
located group collection treatment system is
proposed, confirmation as to the suitability of
the designated site to accommodate the
onsite sewerage facility. Additionally, where
the combined total peak design capacity of
effluent treatment is less than 21 equivalent
persons, the design of the system achieves a
low to medium risk classification in
accordance with Seqwater’s Land Use Risk
Tool for onsite sewerage facilities
1
Solution: Acceptable Solution Page 10 of 10
A/S Alternative Solution D:\JOBS\20-Jobs\20169 - 101 & 105 Eumundi Noosa Road, Noosaville\Civil\Reports\SBSMP\Working\Appendices\20169 - NSC Water Quality and Drainage Code 2020.docx
N/A Not applicable to this proposal Job: 20169
Rev: 0
Site Address: 101-105 Eumundi Noosa Road, Noosaville 30/11/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.