Log in to see the plans as drawn 6. SPEL StormSack Repairs
Depending on the extent of the damage to the SPEL StormSack unit, it can
CHAPTER 4
usually be repaired.
Small tears to the filter bag can be repaired by either sewing the tear back
together with additional fabric to increase the strength of the stitching, or by
sewing a patch of filter material onto the filter bag.
If large tears or irreparable damage to the frame and structure are present, it is
advisable to replace the components.
All required spare parts can be sourced from SPEL Environmental at a cost to
the owner of the SPEL Stormsack.
7. Emergency Procedures
Spills and blockages can be detrimental to the performance of a stormwater management system, potentially damaging
the surrounding built infrastructure, waterways and environment.
Spill Procedures
In the event of a spill discharging into a gully pit, all effected sediment must be removed from the filter bags and the filter
bags are to be removed and replaced with new filter bags. All additional cleaning as a result of the spill should also be
carried out in accordance with the normal operation procedures.
Blockages
In the unlikely event of surface flooding around a gully pit which has a SPEL StormSack fitted, the following steps should
be carried out:
A. Check the overflow bypass.
B. If overflow is clear and surface flooding still exists remove the SPEL StormSack and check the outlet pipe for
blockages. Removal of the SPEL StormSack can be difficult if clogged with sediment and holding water.
C. If the filter is clogged brush the side walls to dislodge particles trapped at the interface allowing water to flow
through the filter.
D. If the outlet pipe is blocked, it is likely that a gully sucker truck will be required to unblock it. Litter can be removed
from the SPEL StormSack using the gully sucker truck before the SPEL StormSack is removed. If a gully sucker
truck is not available and the SPEL StormSacks need to be removed by hand follow the below steps.
i. Remove excess debris by hand or brush the side of the filter bag
ii. Remove entire SPEL Stormsack by taking hold of the inside of the frame.
iii. Unblock the outlet pipe
www.spel.com.au SPEL StormSack | Operations & maintenance 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.