Original source · versioned page text
Appendix A - Amended Driveway Design
PROPOSED DRIVEWAY ALTERATIONS TO EXISTING RESIDENCE AT #51 ORIENT DRIVE, SUNRISE BEACH QLD = 4567 FOR:- ALBERT KHAMU DRAWING REGISTER DATE Mee DESCRIPTION REVISION | ORAWING ISSUED a COVER PAGE, NOTES 23/11/2021 (2 DRIVEWAY PLAN, CROSS SECTION 23/11/2021 G3 DETAILS A 23/11/2021 CHANGES ON SITE WILL REQUIRE DRAWINGS TO BE UPDATED PRIOR 10 THESE WORKS COMMENCING ON SITE, AS PER REGULATORY REQUIREMENTS. 3 z z é é NOTE: ARCHITECTURAL DRAWINGS. FOR SETOUT CO-ORDINATES AND BUILDING FINISHED FLOOR LEVELS (FFL), REFER TO go Bidcument Set ID: 21717145 Version: 1, Version Date: 01/12/2021 gill IS THE BUILDERS RESPONSIBILITY TO CONFIRM ALL LEVELS, SETOUT AND DIMENSIONS ON SITE BEFORE COMME! BEFORE, DURING AND AFTER ANY CONSTRUCTION, SITE DRAINAGE MUST DIRECT ALL SURFACE, SUBSURFACE AND ROOF WATER AWAY FROM ANY CONSTRUCTION AND TOWARD STORMWATER RUN-OFF AS PER COUNCIL SPECIFICATIONS. EXCESSIVE SOIL MOISTURE CAN WEAKEN THE BUILDING FOUNDATIONS. GUIDANCE CAN BE FOUND IN THE CSIRO INFORMATION SHEET ‘GUIDE TO HOME OWNERS ON FOUNDATION MAINTENANCE AND FOOTING PERFORMANCE’ or THE QBCC BOOKLET ‘GUIDE TO PREVENTING STRUCTURAL DAMAGE 10 YOUR HOME’. EARTHWORKS PROCEDURES REFER TO THE FOUNDATION INVESTIGATION REPORT FOR SOIL CONDITIONS EXPECTED ON SITE. IF ACTUAL SOIL CONDITIONS VARY SIGNIFICANTLY FROM THOSE IN THE REPORT, CONTACT ENGINEER FOR ADVICE. EARTHWORK PROCEDURES SHOULD BE CARRIED QUT IN A RESPONSIBLE MANNER IN ACCORDANCE WITH AS3798-1996 “GUIDELINES ON EARTHWORKS FOR COMMERCIAL AND — RESIDENTIAL DEVELOPMENTS”. EARTHWORK PROCEDURES SHOULD INCLUDE THE FOLLOWING:- CLEARING, STRIPPING AND GRUBBING SHOULD BE CARRIED OUT IN AREAS SUBJECT TO EARTHWORKS, ALL SOILS CONTAINING ORGANIC MATTER SHOULD BE STRIPPED FROM THE CONSTRUCTION AREA. THIS MATERIAL IS NOT CONSIDERED SUITABLE FOR USE AS STRUCTURAL FILL. DEEPER STRIPPING MAY BE REQUIRED TO REMOVE TREE ROOTS. DEPRESSIONS FORMED BY THE REMOVAL OF VEGETATION, EG. TREE STUMPS, OR OTHER UNDERGROUND ELEMENTS, SHOULD HAVE ALL DISTURBED WEAKENED SOIL CLEANED QUT AND BE BACKFILLED WITH COMPACTED SELECT MATERIAL. FOLLOWING SITE STRIPPING AND PRIOR TO ANY FILLING WORKS THE EXPOSED GROUND SURFACE SHOULD BE PROOF ROLLED USING A VEHICLE WITH A TARE OF AT LEAST 3 TONNES. AREAS DEMONSTRATING EXCESSIVE MOVEMENT SHOULD BE TREATED (DRIED AND RECOMPACTED) OR REMOVED AND REPLACED WITH COMPACTED FILL. FILLING SHOULD BE COMPACTED AT MOISTURE CONTENTS WITHIN THE RANGE OF -2% 10 +0.5% OF OPTIMUM MOISTURE CONTENT FOR STANDARD COMPACTION. CONFIRMATORY TESTING MUST BE CARRIED OUT AT REGULAR INTERVALS. A MINIMUM OF TWO TESTS PER 300mm VERTICAL INTERVAL IS RECOMMENDED WHERE STRUCTURAL FILL HEIGHTS ARE TO EXCEED 300mm AND A MINIMUM OF 1 TEST PER 100m? OF COMPACTED FILL. SELECT FILL SHOULD HAVE A MAXIMUM PARTICLE SIZE OF 100MM FOR UNCOMPACTED LAYER THICKNESS OF 200MM AND SHALL BE COMPACTED BY REPEATED ROLLING WITH A COMPACTOR 10 ACHIEVE THE SPECIFIED DENSITIES. GUIDELINES FOR MINIMUM RELATIVE COMPACTION VALUES FOR INSITU SOILS AND IMPORTED FILL FOR THE BUILDING AND PAVEMENTS ARE PRESENTED BELOW. Location Minimum Dry Density Compaction Building Area 98 Pavement Area a) >0.3m below pavement subgrade 95 b) <0.3m below pavement subgrade 98 Note: The recommended Compactions are percentages of the maximum dry density determined by Australian Standard 1289 5.1.1 (Standard Compaction). BACKFILLING FOR SERVICE TRENCHES, ETC SHOULD USE GOOD QUALITY MATERIAL. THE BACKFILL SHOULD BE PLACED IN UNIFORM LAYERS OVER THE FULL WIDTH OF THE EXCAVATIONS WITH THE LAYERS NOT EXCEEDING 200mm THICKNESS, LOOSELY PLACED. THE BACKFILL MATERIAL SHOULD BE COMPACTED TO THE SPECIFICATIONS OUTLINES ABOVE FOR INSITU OR IMPORTED COHESIVE MATERIAL. SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE CONSTRUCTION COMMENCING. THE SITE MUST BE MAINTAINED IN A FREE DRAINING STATE AT ALL TIMES, NO WATER SHALL BE ALLOWED TO POND ADJACENT ANY BUILDING PADS. ALL WORK SHALL BE CARRIED QUT IN ACCORDANCE WITH THE RELEVANT STANDARDS, MAIN ROAD STANDARD DRAWINGS AND IPWEAQ STANDARD DRAWINGS. CARPARK DESIGN BY OTHERS. REFER ARCHITECTURAL DRAWINGS FOR DESIGN AND VEHICLE MOVEMENTS, ETC. ALL LINEMARKING AND SIGNAGE SHALL BE IN ACCORDANCE WITH DMR "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES". INSTALLED PRIOR 10 COUNCIL EARTHWORKS NOTES 1. 4 ‘ad, 42. 5. 5A. 5.2. 8. 8.1. 8.2. 9. ALL DRAINAGE, EROSION AND SEDIMENT INSTALLED AND FULLY OPERATIONAL UP-SLOPE EARTHWORKS. CONTROLS 10 BE BEFORE — COMMENCING ALL EXISTING UNDERGROUND SERVICES TO BE LOCATED AND MARKED PRIOR 10 COMMENCING EARTHWORKS. EARTHWORKS, ASSOCIATED WITH BUILDING T0 GEOTECHNICAL/STRUCTURAL ENGINEERS SPECIFICATIONS. FILL DENSITY TESTING SHALL CONFORM TO THE FOLLOWING: 1 TEST PER 500cum - GENERALLY 1 TEST PER 2 LAYERS PER 40m - TRENCH BACKFILL PLACEMENT OF FILL SHALL CONFORM TO THE FOLLOWING MINIMUM DRY DENSITY RATIO (M.0.D.R.) COMPACTION STANDARDS: PAVEMENT SUBGRADE = 98% STD FOR NON-COHESIVE MATERIALS, M.D.D.R. = 75%. ALL AREAS SUBJECT TO EARTHWORKS ARE TO BE FREE DRAINING WITH A MINIMUM SLOPE OF 1:10. ALL TEMPORARY STOCKPILES (IF APPLICABLE) TO HAVE 1:6 MAXIMUM SIDE BATTERS (GRASS SEEDED). EARTHWORKS BATTERS ARE TO CONFORM TO THE FOLLOWING: 1:4 OR FLATTER TO BE GRASS SEEDED, UNO. STEEPER THAN 1:4 TO BE MULCHED AND PLANTED IN ACCORDANCE WITH LANDSCAPE PLANS. IMPORTED FILL TO HAVE MIN EQUIVALENT CBR OF 15%, FOR THE INSPECTION OF DRIVEWAYS AND CROSSOVERS, ETC, IT IS THE BUILDERS RESPONSIBILITY TO ENSURE GRADIENTS AND SETOUT IS ENGINEER WILL ONLY AND SLAB THICKNESSES. REQUIRED CONFIRMING THE GRADES AND SETOUT TO ENABLE THE ENGINEER TO CERTIFY THE CONSTRUCTION. CORRECT. THE INSPECT REINF'RCEMENT, COVER A SURVEY DRAWING WILL BE CAUTION WITH EXISTING SERVICES ALL EXISTING SERVICES WORKS PRIOR TO THE START OF ANY CONSTRUCTION. EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR. THE CONTRACTOR IS TO DETERMINE THE EXACT LOCATION OF IN THE VICINITY OF THE PROPOSED COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO NOTE: e (CUT AND FILL SHADING REPRESENTS NATURAL SURFACE AND BUILDING PAD LEVELS BELOW FFL). e ROAD BOXING 300mm BELOW FINISH SURFACE LEVELS. EARTHWORKS BETWEEN (ASSUMED 200 IN LANDSCAPING AREA REFER TO LANDSCAPING DRAWINGS. P Rane This drawing is not to be copied or amended yithout yrilten permission from Rienmac Consulting Engineers RIENMAC eryiro ABN. 52 010 666 430 ACN. 010 666 430 CONSULTING CIVIL & STRUCTURAL ENGINEERS SUNSHINE COAST OFFICE: SUITE 5, FIRST FLOOR, SAINT CIRINO, 137 BRISBANE ROAD, (PO BOX 149) MOOLOOLABA OLD 4557 CLIENT: ALBERT KHAMU PROJECT; PROPOSED DRIVEWAY ALTERATIONS #51 ORIENT DRIVE, SUNRISE BEACH QLD P:- (07) 5349 0762 Email:- [email protected] Web:- www.rienmac.net 4567 REAL PROPERTY DESCRIPTION & COUNCIL: LOT 4 ON N21840. NOOSA SHIRE COUNCIL DRAWING TITLE COVER PAGE NOTES Designed: AW/PLR Drawn: AW SCALES: Engineer: PLR DATE: 22 NOV 21 21666 C1} A JOB NUMBER DWG No. ISSUE PETER RIENECKER - RPEQ 2088 DO NOT SCALE OFF DRAWINGS. A3 |SHEET 10F 3 |CHECKED: PLR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.