Skip to the record
The only place to find full transcripts.

Council archive · source document

09/1689 - Response to Information Request [As Published] · 132009.1689

of 11

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

 

Courcil’s Reference’ 2009/1589

 

Our Reference 1164 LO6 NG . 7 7
consulting =
17" February 2010 pty Itd
town planners +
urban designers
+ surveyors
Chief Executive Officer

 

 

Sunshine Coast Regional Council
Locked Bag?2
SUNSHINE COAST MAIL CENTRE QLD 4560

ATTENTION: PLANNING NORTH- JACK LEWIS

Dear Jack

RE: _ INFORMATION REQUEST.
APPLICATION FOR DEVELOPMENT PERMIT FOR MATERIAL CHANGE OF USE OF
PREMISES FOR MULTIPLE HOUSING — TYPE 2 DUPLEX AT 13 GRANT STREET NOOSA
HEADS; 2009/1689

| refer to the above application and in particular to the request for additional information issued by your
Council and dated 6” January 2010.

This request listed five (5) items that your Council considers is necessary in order to complete its
assessment of the above application. The applicants have decided to respond to these items as below:

Item 1: Removal of gate along the access dnveway at the street frontage,
Applicants response: Gates along street frontage removed - refer Burleigh Design Plans 08-3781-1/7

Item 2; Provide a revised vehicle manoeuvring plan that indicates adjacent walls, vehicles
overhands and manoeuvring clearances.

Applicants Response: Revised vehicle manoeuvering plan provided - refer Burleigh Design Pian 08-3781

5/7.

Item 3: Please provide a revised longitudinal section of the access driveway.
Applicants Response Revised longitudinal section of the access driveway provided - refer Burleigh
Design Plans 08-3781 3/7,

item 4; Please provide a pretiminary stormwater disposal design for the site.
Applicants Response: Preliminary stormwater disposal plan provided - refer Burleigh Design Plans 08-
3781 SKO1,

ftem 5: Provide soft landscaping around perimeter of entire site including the south east boundary.
Applicants Response: Amended plans indicate soft landscaping around most of the perimeter of site -
refer Burleigh Design Plans 08-3781 1/7

The applicant company considers that it has now responded to Council's request for information. The
decision making period has therefore commenced and we request that your Council proceeds with its
assessment of the above application as soon as possible. Please contact our Sunshine Coast office if you
require any further information and/or clarification

SUNSHINE COAST OFFICE GYMPIE OFFICE
1-139 GYMPIE TERRACE NOOSAY _LE - PO BOX ‘684 NOOSAHEADS @ 4567 232 MARY STREET GYMPIE - PO BOX 301 GYMPIE Q 4575
TELEPMONE 07 54555425 - FACS MILE 07 54555725 TELEPHONE 07 54827440 - FACSIM'_E 07 54824952

wa @martcccacswiting com ma: @matcocecsu tig com

 
Full text of the other 10 pages

Page 2

@ Page 2

Yours faithfully

Nadine Gorton
Senior Planner
martoo consulting pty Itd

Enc

1x A‘ Burleigh Design Plans 08-3781 1 to 7 and 08-3781 SKO1.

Page 3

PROPOSED DUPLEX FOR
N, RA & GC TOKOVIC

13, Grant Street,
Noosa Heads, QLD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

INDEX Sel |
SHEET No. SHEET TITLE > +
1 Site & Floor Plans N - I -
2 Elevations he
3 sections
4 Complience
D Vehicle Manoeuvre
6 3d Perspective
f 3d Perspective

Page 4

a 322° 55°20" 19.929

 

oy . \
Handrail 4.0m | ~
above FFL

 

 

 

 

 

52°55" 20" 33.744

J Nb

 

 

 

 

RN Oy ae TT
. v
x ay

 

 

 

 

 

 

 

 

 

 

: BN LEVEN SIRS, PLS LEE at
. Be Roll under u
a PTI RSH] e-
Brick Edgng fe Pg EE lg Fag
Retain under edge of ‘Nt _ HLL. 33 oe Ne! -
driveway max 450 a TS ~ je
Digg int 36.938) a 5
=e) (ROG 28) Ss eo
DRIVEWAY NOTE Rips ae ar : | “
Driveway gradients ” 4 N aft ‘ ft 18. x _ aro all 8 ic
compliant with Standard Sf: SLOPE raf ty SN =e) i Perf) | tae a
drawing SEQ R050 io} . ~ SLOPEI >, ‘for hl ~ oe E
iB ok . ft i. sa) tb
A ms Ne a S
cd Sh (ROTO) AALS hed TEESE
ef ES are po
a.) . : Z ty KE
a ieee by Hf |<

 

oa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
   
     
     
    

Timber Fence 1.8m High Max.

Handrail 4.0m above FFL

 

7 i ah
ae J me EL ! Py
Provide 200mm landscape “tm 48 Down \ i. A. ao TA 3 pet perce! uy S
. afgee _ i TN 5 i pie est > ~
strip with creepers ~ \ f i "tye Bath ss 2 xt
i 4
2000 high solid timber fence
at natural ground level
Retain under edge of _
driveway max 450
Ss
s
Ss
i
we = h f La
sone " ae Ow Ro
b : - Aluminjum Slatted Fence
3... back of kerb 50% open
° *

 

   

RL 20,23
TBM

Screw in Kerb

 

 

oe ye - en
Bin Enclosure edge of bitumen ‘ \
'— & Letter box SS
Solid Rendered Fence SO

 

Solid Rendered Fence
Area

 

~ white lane marking

GRANT STREET

bitumen “formation —

 

 

‘\
_ white lane > marking bottom of'stone wail

top of stone wall

edge of bitumen

GIROWINID FLOOR PILANNI

Notes

Muitiple Housing Type 2 Duplex

Building Height - 2 Storeys and Max. 8.0m High
1 Covered Carspace per Unit

1 Visitors Carspace per Unit

Property Description

Lot No. 13

SP No. 179879

Area of lot 672m?

Parish of WEYBA

County of MARCH

Site coverage 252.99? (37.65%)

Total GFA 301.92m? (44.93%)
Max. 302.40m? (45.0%)

Energy Efficiency

TO BE READ IN CONJUNCTION WITH
ENERGY EFFICIENCY REPORT IF REQUIRED

INTERNAL LIGHTING

80% of total intemal floor area of the building,

including an associated garage, shall be

illuminated with fluorescent or compact

fluorescent lighting with a max. output of 27 Lumens/Watt.

PLUMBING FIXTURES:

-All shower roses to be 3 star rated water

efficiency labelling and standards (WELLS) rating.
-Pressure limiting devices to be fitted where

main water availabie. Pressure not to exceed 500 kPa.
-Toilets to be duel flush and have a min 4 Star WELLS
tating and are compatiable with the size of the toilet bowl
to allow proper function of the toilet.

TAPWARE:

Tapware to have min 3 Star WELLS rating for taps serving;

(A) Laundry tubs.
(B) Kitchen sinks.
(C) Bathroom basins.

HOT WATER SYSTEM
Hot water system tu be one of the following;
(A) Five star gas hot water system.
(B) Either a heat pump or solar hot water system where:-
{i) in a building with 3 or more bedrooms, the hot
water system must be eligible to receive at least
22 renewable energy certificates; or
{ii} in a building with 1 or 2 bedrooms the hot water
system must be eligible to receive at least 14
renewable energy certificates

WATER TANK:

§000Litre Water tank to Local Authority Requirements.
Tank water to be connected to toilet system,

washing machine cold water and extemal hose cock.
Tank to be connecied to minimum 100 square meter
of roof catchment.

Mosquito protection as per QDC MP 4.2 and 4.3

Area

Unit 1

01 Ground Floor 91.38 m?

02 First Floor 93.83 m?

03 Undercroft 16.32 m?

04 Lower Deck 11.93 mm?

05 Upper Decks 46.18 m?
259.64

Unit 2

01 Ground Floor 102.90 m?

02 First Floor 98.81 m?

03 Lower Decks 15.48 m?

04 Upper Deck 17.22 mm
234.40
494.04

 

 

 

 

 

2589

 
 
     
 

n if ERY 8
hm oA

mn rogm
ARES it] + “i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     
  
    

»
_--— Handrail 1.0m above FF.L

5830 |

 

—~ Handrail 1.0m above FFL

 

  
   
 

 

 

 

>

] nen
[RL 19.598] x
Bt Fold Doors ta »~
_ eat ee, ba x
Hee bing rom Ww ! =
fey foot bo
4 f | % =
if ce Handrail 4.0m
1 BY — above FEL
‘ jae
Rb]. 1 JAR
45) isi
ae >
«fed oe as
< 3
. RS = baBin Enclosure nown 2
ae a 48 Letter box 8
cise Area ”
cn a —*
Ch P Aluminium Slatted Fence
Soper 50% open

 

G

 

4006
Deck

 

issue B 61-02-10

 

NOT FOR CONSTRUCTION

 

 

 

Solid Rendered Fence

ANT STREET

[ Solid Rendered Fence

PURST FILOOR [PILZNIN

 

 

 

 

These plans may not be copied in whole
or part without the written permission of
Burfeigh Design
Copyright ©

PROPOSED
DUIPILIEZS

N R&C TOKOVIC.
13, Grant Street
Noosa Heads

Site & Floor Plans

1:100, 1:1 at Al
lof?

 

 

 

 

 

 

 

08-3781

 

 

 

Page 5

( ) Aluminium tramed glass louvies
ye
wad
8.0m Height tine i 8.01 Height Line
1 * ~ °
' . -
' ~ . “ |
| Polished HWD Battens* + ‘ S
\ uO ,
i |
i 2
vty =

Polished HWD Batiens
$.0m Height Line

 
 

 

 

 

 

 

 

 

 

 

Aluminium framed sliding glass window

 

 

 

 

 

 

Aluminum framed glass louvres ( - )
. pe
Timber Framed BiFolding Glags Doors

Stramit XRW corrugated root

|
|
al / " sheeting to be selected

—— Colorbond gutters and downpipes

Gag Level

|
I
|
1
{
i
i
1
1
1
1
'
'
4

Flor Lee

~ Ceiling Level

   

Floor Level

Applied rendered tinish

NORUAPEAS ILEWATIOLN|

: ~/Strami

a

!
rode

Timber Framed BiFolding Glass Doors f . yt

  

Aluminium framed sliding

  

glass windows

Handrail 1.0m above F.F.L

Aluminium tramed glass louvres

it
ely

boa,
ARW corrugated rol sheeting to be Selected

a
} i

Aluminum tamed sitding glass windows
& ,

4

 

 

 

 

 

 

 

 

 

wry 3 5 ( +)
. re “ ° fo, in
| oa
low
1S
1d
4
|
!
; Ceiling Level
|
f
1
1 Floor Level
4
1 Ceiling Level
|
|
|
hoor Level
4

a

 

Applied rendered finish

 

 

SOW WWE

J 1s

 

 

LIEWATIION

 

Aluminium framed Ined glass windows (obscure)

: oo
. ooo ; -- = Applied rendered tinish / ‘ _ Aluminium tramied tixed glass windows (obscure), )

ae 2S ~ fe ; ~

t fo: ‘ : |

—_
a

 
  
 

Bourtay

 

 

 

   

 

   

 

 

 

 

 

      
    

   

  
  

    

 

 

 

 

 

 

Ceiling Level
; ae = Catling Level
tl oa E
Geling Level SR © Floor Level
_ so oor Leve
~ Ceiling Level
Floor Level
_. Floor Level

Applied rendered tin'sh to 200 series Concrete tilock é

Applied rendered finish
— Aluminium framed glass louvres

\ ‘ Finished ground line
Finished ground line \

NIORUTIUAWIEST SILIEWATIOIN| \

Applied rendered finish

Stramit XAW cortugaled roof sheeting to be selected 1 ,
. aon 8.0m Height Line
Stramit XRW corrugated root sheeting to be selected ; :

 

| Aluminum framed glass iouvres .

5

Weatherboard external cladding le be selected - '

   
 

! j
oe

    
  

C)

r Aluminium framed glass lowes —
1
I

Boundary wh :

 

 

  

 

 

 

 

 

 

* Gelling Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

  

 

 

 

 

 

 

 

  
 
 

 

 

 

 

 

 

 

 

 

to. . tes a &
8.0m Height Line, Sat ¥ . Ey SS
Ceiling Level ro = 5
co e Ly tg an
Ee hah Ox Floor Level
Ly Ceiling Level
Fivor Level Fi Bin Enclosure
Ceiling Level & Letter box
Nea Floor Level
Floor Level
Floor Level _ — ——____ Or Lev

Finished ground line

-- basting ground line

Alumuniuin framed glass loowtes | __ Applied rendered tinsh to Hardies Base sheet

~ Applied rendered finish to Hardies Base sheet

Handrail 1.0m above FFL

 

 

 

SOW VnsEAST [sible W/ATLOWN

IssueD 01-02-10
NOT FOR CONSTRUCTION

 

 

 

 

These plans may not be copied in whole
or part without the written permission of
Burleigh Design
Copyright ©

 

 

PROPOS[sD)
DURE
“WR&.C TOKOVIC

13, Grant Street
| Noosa Heads ~

 

 

 

Elevations
4100 at at
i 2017

 

08-3781

Page 6

1a

Bou

Ceiling Level

Floor Level

*

Ceiling Level

2540

Floor Level

i,

{ey

Unit 2

=

 
     
   
  
 
  
  
 
   

 

Carport =

vy Ait

 

(RL) |

Roof pitched at 5°

| ~ Timber tramed toot trusses «ai 600 ¢/s to manutacturers specitications

| olramit XRW corrugated root sheeting to be selected

Timber Ratters

|
| |
: - i _
1
|
|
iH

04 qd lived walls & caging
Lounge it
: : it

 
 
   

 

Remforced concrete slaty & footings to Engineers detail

|

SCUTON Aed\

    

\
\
I
\
1
\
1
I
I
1
|
\
1
1
\
1
|
\

|
Line of Unit
Carport slab
_1500 + aporsia
Rell under | one
[15.938 (RIS
- p Lo °
5TH (

 

       

RL

 

C oo

ee)

1500
Roll under

Unit 1
Carport

16.254 (RLS

7 16.938 (RI

IEG ITMIOIN! (9) [OER

  

 

LS,

‘Timber floor wosts. - :

Line of Unit 1
Carport

Roof pitched at 5°

Boundary \

Timber tramed ioot trusses «2 600 ¢/s to

8.0m Height Line oo a a
Manulacturers specitications

         
 
       
       

 
 
 

 

 

I |
| | \
| | |
I | I
| |
\ \ ' \
; 6389 ‘ | Stramit XRW contugaled root sheeting to be selected |
8.0m Height Line ! | a 2000:
5230 / ' Timber Ratters ‘ ~ Colorbend gutters and downpipes
—_ ; Celling Level . Bo Ceiling Level
Timber tramed root trusses «2 | | ogg Plasterboard lined walls $ e8ying oe Weatherboard external cladding
600 c/s to manufacturers 1 = ‘ 1 Kitchen FO 1900 | to be selectec =
Specifications : | l ~—— Timber Flooy sls : ' ~
\/ 18.298 (RL) , Foor Level . o ‘7 19.598 (RL) Floor Level
- Oa t Geling Level | f my AIPA iL i ~ Giling Level
ag, Weatherboard external 1 | i ne Inga walls & geiling | Weatherboard external cladding o
See ladding to be selected a i Work Station <<, 10 be selected x
: wy Floor Level | 7 96,836 (RL) Foor Level

5.538 (RL) |
“1 ea Finished yround line «]

  

 

 

 

 

         
  
   
  

  
    

SLOPE 1:4

be

 
 

 
   
      
 

ue i <7 15.938 (RL) Foor Level 52)
Existing ground line 1 Reimtorced concrete slab & footings to Engineers detail
aS
SECTION [32/83
I.
jer Existing Bottom of _
1000 1000 fs / ground level stone wall
5 | 3 Existing kerb Existing road
RAD. SLOPE 16 se 1-201 / / /
we TT EE 90.000 (RL)
| ane eu re (RL) _ of Poo eee ee
vy 19.783 (RLY = Ta a -
|
' Driveway .
surface level \ ive
' \ it : "
\ N a a i
eee ee
' a TS
; mem , _ Existing

ground level

DRIVEWAY NOTE

Dnveway gradients
compliant with Standard
drawing SEQ R-050

[OTL WISIN? (OLEINTUTRLELCULYIES

 

i] / __ Concrete Bock
1997 7 retaining wall
7 Roll over. /
yd
SLOPE 1.4 16.750 (RLY

WWE

  
  
   

Existing
ground level

 

DSU/MIIL

 

|
i
i
i

 

issue B 01-02-10

NOT FOR CONSTRUCTION

 

 

 

These plans may not be copied in whole
or part without the written permission of
Burleigh Design
Copyright ©

BROROSED)
[OWL lean
N Ra CTOKOVIC

13, Grant Street
Noosa Heads

 

 

 

Sections

1:100, 1:50 at Al
3 of7

 

08-3781

 

 

Page 7

_——_—___— —

18LE-80 LIOY
LW 1-1 ‘OO

AIUaIjanUGy

speay eSOON
J99]S UPI ‘E]}

INONOLD 2 4'N

sl Vel(MG
Gs|SOdOele!

— @yyBukdos -
uBisaq uBteyng

Jo uolssituad UanUM alg ynouyM Wed JO
aJOUM ut pardco aq you Aewu sueyd asay |

 

 

 

 

 

 

 

NOLLONYLSNOD HO LON

 

 

 

01-20-10 g anss}

L

 

SMOMLWINIUW2)
Wel®) SOO Us! LSelle!

  
      

[___ THN SL9g :raay |
VAD soo}g 1514 1 0/7 ZO

 

: it .
[za s0't6 Fay | _ |

VAD 10H] ISIE Z WUD PO A, (
ly
Yj

SNOILWINDWD Wel)
tO OMEEG NMOS

 

 

[TM g9GS :eOIY

VAD JOLY punosy 1 9) 10

  
      

   

“a

ty

yj

_ _ TH Sp'RO [HAA |
VAX) FOO,] punosrry Z HO) CO

              

         

      

SS

NOULLWTUND WW)
GISINOO) sibs

“006 T Toe

 

1nQ JOoy J aU] ——

 

 

 

 

 

 

 

 

 

 

 

=. - - J@AQ Jooy Jo aur]

         

--- JBAQ JOOY Jo uly

i

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t
ie
J9AQ jooy joaun -
MSOLE
ZW 66°ZSZ BOTY LD
AAD ING LD
\ DB
Y
|
wb JAAQ JOO JO AU
009
26 LOE
7 GOL6 WAD 100}4 S44 J PUN O
2 GY'89 WAD Jooj4 PUNO) Z YUN €O
zl G/'98 WAD J00}4 YS4I4 | WUN ZO

ZW 99°GS VAD Joo|y punosy | Wun LO

suolenzjey Bary JOO}4 SSOID

Page 8

 

 
      

 

= Ay
woe

| i,

’
‘
/
/
f ed
f
!
!
\
1
'
'
\ |
1 i
\ :
1
4
\
\
\
1 :
1 i

 

 

  

 

 

 

 

Umit 2
Wisitor Carpark
Manoeuvre (Plan

 

 

 

 

 

 

Umit 2
inesidence Carpark
Manoeuvre Pian

 

 

 

 

 

 

 

Uri
WIsitor Carpark
Manoeuvre Plam

 

 

 

 

 

 

 

 

Umat 7
Residence Carpark
Manoeuvre [Plan

 

issue B 01-02-10

 

NOT FOR CONSTRUCTION

 

 

 

 

 

of part without the written permission of
Burleigh Design
Copyright © .

‘PROPOSED
DUPLEX

 

These plans may not be copied in whole

 

 

 

N, R&C TOKOVIC
13, Grant Street
Noosa Heads

 

Vehicle Manoeuvre

1:100 at Al

9 Of? 08-3781

Page 9

              

 

 

 

 

 

 

 

 

 

 

 

iui

Wu

pec

aun!

 

 

BAST

PIEIRS PEC TINTS

 

 

Act
Sah
ttt

 

—

 

WEST PERS

 

PIECTlWis

 

 

 

 

 

J PERSPECTIVE

 

 

 

  

 

 

 

 

 

Issue B 61-02-10 |
NOT FOR CONSTRUCTION

 

 

 

 

 

These plans may not be copied in whole
or part without the written permission of
Burleigh Design
Copyright ©

IPIROPPOS[ED)
(DUTP Lede

 

 

“WLR&CTOKOVIC

18, Grant Street
Noosa Heads

 

8d Perspective

1:100 at Al
6 of7 08-3781

Page 10

 

 oaMaadsJad PE

SpeoH PSOON
J99NS eI “EL

JINONOLD 2 Y‘N

| XEAAG
| GASOd Oud

@wEukdog
ubisaq yBrepung
JO UOISsILLUad LepUM aly ynoUyWM ped JO
BIOUM LI paidoo aq jou Aew sued asouy

 

- NOLLOMYISNOD 804 LON

L8LE-80 LOL

 

ite
Se
we

SNES

 

 

01-20-10 g anss}

SVN ALOsle Selelel ILSel/in

 

LU Lgiaindhge eae wpe ne ainaenceed, ner dae ee ia ye paths 6 oo ie sind SS AE oe SPE Soe dont anche adapta les COP

sg as ay

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

i= Son 1.

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 11

5000 litre Round squat

 

 

 

   
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
   

 

 

 

 

 

 

 

 

 

 

 

 
    
 
    
     

 

 

 

 

 

 

 

 

 

 

 
  

 

 

     
 

 

  

 

  
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   
 
 
 

 

 

 

 

 

 

 

 

> Rainwater tank below deck \g22° 55'20" 19.929 ~
grated \ — Rainwater tank overflow b 73
stormwater ~ . 8
pit . _ -
ee —- — EASEMENT AD
a IL 12.89 we
4... [- SL 13.75 Te ee es ]
we oe ~ te KN ae
Pi | ac
| .. — Field gully
1 -
1
1 ~ Field gully
PVC stormwater pipe. \ K
Py
dp
’
75 '
~ $n. . ah
1
~ " .-- — Field gully
Stormwater
stip drain.
16 i me ~
: i Nags nen Des Ve Pee “AS '
~ S cool ~~ sonnet tne Rainwater tank overflow
Stormwater > . ~~ 48
strip drain. 4 5000 litre Round squat
i . i. Rainwater tank below deck
zh J
ped : PVC stormwater pipe.
-(c ¥ Stormwater +” ep
g 4 SO stip drain. \ a
wl; ~ Pd
ob *~ \ '
NYS ~
ors Te ‘ vq
Ir : SLL SER BESS NB
ra oe
pp Lifes
oh ng
i ryt =
B i
He
t i
oh HLT
= PRM me fy]
a oR
: L \
Li f a
ia tf
Be. a LJ Field gully
1g-- ye Oa [
a we A
! : tL Ea
rd Driveway
i C1 “on Field gully
~ ee eS i RL 16.538) _.
to . : L a put . | Field gully
vy =, 2 \
id tt Me ~ Spoon drain ‘5
79 ' Fs a, ~ mee —-N
Te. p ~ ro
4 ~~ \
~ 4 a ee
StF ~~
4 ; we |
0 i a
4 7 eens sweesornere!teerrrorvnerere! Seem ceerer
322° 55' 20" 19.929 '
i
t
back of kerb /
ST edge ot bitumen SS - . ~
XN
- white lane marking bitumen formation -
N

GRANT STREET ~~

— = ~ ‘
b oo white lane marking bottom of stone wall_

 

top of stone wail

edge of bitumen

TRAFIC ONE WAY

SVORMWATIER MANAGEMENT PLAN

 

 

 

SK 01 01-02-16

 

NOT FOR CONSTRUCTION

 

 

 

 

These plans may not be copied in whole
or part without the written permission of
Burleigh Design
Copyright ©

 

 

 

 

PROPOSED
OU PLEX

 

 

N,B & C TOKOVIC
13, Grant Street

Noosa Heads

STORMWAT

ER PLAN

 

 

1:100 at At
SK 01

08-3781

 

Used in these records

About this file

File size
2.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1689 - Response to Information Request [As Published].pdf · 2.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.