3.8 An average of 3m soft landscaping shall be provided along the Elanda and Ferguson
Street frontages.
4. Cleared vegetation is to be suitably processed by one of the following methods and removed
from the site:-
4.1 Processing through a woodchipper or shredder. The resulting mulch is to be stockpiled
loose in heaps of less than 1000 cubic metres, less than 2.5 metres high with a
minimum of 10 metres between edges of heaps.
4.2 Disposal for firewood.
4.3 Disposal for landscaping purposes.
4.4 Transport to alternative site for breaking down materials provided that all necessary
permits have been obtained to allow the alternate site to be used for this purpose.
4.5 The disposal method for clearing works is to be submitted in conjunction with an
application for a Development Permit for Operational Work. The Applicant is advised
that other methods may be considered provided full details of the method are
submitted.
4.6 The Applicant is advised that burning off is an unacceptable method of disposal.
5. All fencing shall be setback at least 1 metre from the front property boundary, with at least half
of the fencing setback 2 metres. The area of land between the fence and the front property
boundary shall be densely landscaped to screen any fencing from the street.
6. The development shall not exceed 2 storeys and 8 metres above natural ground level and
finished ground level.
7. A verification survey of the building is to be carried out by a Licensed Surveyor and a
certificate lodged with Council at completion of work confirming compliance with the maximum
allowable building height as required by either the conditions of approval or the Planning
Scheme.
8. All hot water systems installed shall be either solar systems; electric heat pump systems; or
gas systems (LPG or natural).
9. All new kitchen, laundry and bathroom fittings shall comply with the AAA Water Conservation
Rating System as defined by the AS/NZS 6400 (Water Efficient Products - Rating and
Labeling 2003) and AS/NZS 3500 (National Plumbing and Drainage Standard Part 1), with
toilets to comply with the AAA Water Conservation Rating System. All new tap ware and
shower roses shall not exceed a maximum flow of 9 litres per min. Dishwashers and washing
machines are excluded from this requirement.
10. Any deck or balcony areas are not to be enclosed with shutters, glass panelling or the like,
thus remaining as open structures.
11. The gatehouses located along Ferguson Street are not permitted within the setback area and
are to be removed to allow the retention of existing vegetation that will buffer the proposed
building.
12. Security in the form of a cash bond or trading bank guarantee to the sum of $10,000 must be
submitted, to secure performance of all conditions of this approval, prior to the issue of a
Development Permit for Operational Works. The cash bond or trading bank guarantee will be
returned on performance of the conditions of approval less any costs incurred by Council in
respect of enforcing performance of this permit.
13. The requirements of this development approval are to be effected, prior to the use of the
premises. Council reserves the right to call upon the bond or guaranteed sum referred to in
this approval to effect compliance with conditions.
Page 3 of 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0019EB06.001.pdfRelated documentPublic source context ↗
SUPERSEDED Decision Notice - 010.2008.00002063.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 80 KB (small file)
- File type
No other editions are linked here.