I refer to your application and wish to advise that we require further information to satisfactorily
assess the proposal. Please provide four copies of all information to be supplied, including an A3 set
of plans and a CD copy.
1 APPLICATION DETAILS
Application No: 2008/310
Proposal: Community Centre - MCU Wellbeing Type 2 - Social
Street address: 1 Woodland Drive PEREGIAN BEACH, 3 Woodland Drive PEREGIAN
BEACH
Real property LOT: 150 P: 93132, LOT: 151 P: 93132
description:
Planning Scheme: Noosa
2 INFORMATION REQUIRED
The information requested is set out below:
1. Please provide a site plan showing accurately the location and the depths of the existing
sewer main on the site and its zone of influence. The ‘zone of influence’ is taken as the area
within a 45-degree angle measured from the invert of the sewer main to the finished surface
level.
To ensure Council’s sewer main is accessible for maintenance purposes and is protected from
risk of damage no structures requiring a building permit (eg. buildings, water stormwater tanks,
retaining walls exceeding 1m in height, raised terraces, etc) shall be constructed within this
‘zone of influence’ or within 1.5m of the centreline of the sewer main, whichever is the greater.
As such the applicant will be required to create a sewer easement over the zone of influence
at a minimum width of 3m. The proposed building as shown on the submitted plans may need
to be relocated to ensure compliance with above requirements. Any amended site plan of the
proposal should show the sewer main and the proposed sewer easement.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
-2-
2. Indicate the location of stormwater tank/s on the plan as all roof water runoff from any new
building should be directed to a rainwater storage system or tank (with a capacity the greater
2
of 5000 litres or 15 litres/m of roof area) that is installed to ensure water from the tank is used
for external uses (such as watering gardens, irrigation, ornamental ponds, water features,
topping-up swimming pools, outdoor cleaning, etc) and for use in flushing of toilets internal to
the building.
It should be noted that the stormwater tanks should not encroach on any future sewer
easement on the site.
Under the provisions of the Integrated Planning Act 1997, you have three options available in
response to this Information Request. You may give the assessment manager (in this instance
Council) and each referral agency (if any):
1. all of the information requested; or
2. part of the information requested together with a letter asking the assessment manager and
each referral agency to proceed with the assessment of the application; or
3. a letter:
(i) stating that you do not intend to supply any of the information requested; and
(ii) asking the assessment manager and each referral agency to proceed with the
assessment of the application.
Please be aware that under Section 3.2.12 of the Integrated Planning Act 1997, the applicant is to
respond to any information request within 12 months of the request or otherwise, the application
lapses.
A response to the above is required to be submitted, prior to further assessment of the application. If
any further matters arise as part of assessment of this application, you will be advised accordingly.
Should you have any further queries in relation to the above, please do not hesitate to contact me on
the above number.