5. Appendix B - Architectural Drawings
Very large file (74.6 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 14, section 1. The text section number identifies this passage in the reader.
PROFILED METAL ROOF SHEETING ON PREFABRICATED STEEL PFC WALKWAY TENANCY ENTRY STATEMENT
INSULATION BATTENS & PURLINS ARBOR STRUCTURE w/ DANPALON (OR TO FUTURE DETAIL
FRAMING TO STRUCTURAL ENG. DETAIL SIMILAR) USED FOR ROOF SHEETING
CONC. TILT PANEL WALL
REFER STRUCTURAL ENG. DETAIL
ROOF
10.200 m
LEVEL 1 SIGNAGE PANEL FIXED TO FEATURE TIMBER
6.000 m BLADES TO FUTURE DETAIL
TENANCY 21
TENANCY SHOPFRONT CARPARK
GROUND FLOOR
3.000 m
PEDESTRIAN WALKWAY HARDSCAPING
ELEMENT TO FUTURE DETAIL. REFER TO PLAN
FOR LAYOUT
CONCRETE TILT WALL TO R.C FLOOR SLAB AND FOOTINGS TO
FUTURE DETAIL STRUCTURAL ENG. DETAIL PEDESTRIAN WALKWAY
1 BUILDING 3 - Section c
A-DA-1203 1 : 100
3075
TENANCY ENTRY STATEMENT PROFILED METAL ROOF SHEETING ON
1100
TO FUTURE DETAIL INSULATION BATTENS & PURLINS
FRAMING TO STRUCTURAL ENG. DETAIL
TENANCY 22
3800
2700 1100
3800
CURTAIN WALL GLAZING
TREATMENT TO EXTERIOR
2700
9645
15000
1100
TENANCY SHOPFRONT w/ INTEGRATED
MULTI-FOLD DOORS TO FUTURE DETAIL
3800
2700
CONC. TILT PANEL WALL
LEVEL 1 REFER STRUCTURAL ENG. DETAIL
6.000 m
TENANCY 02
3000
2800
ARBOR STRUCTURE FOR SHADING
TENANCY SHOPFRONT
GROUND FLOOR
3.000 m
PEDESTRIAN WALKWAY CARPARK PEDESTRIAN WALKWAY
2 MIXED-USE PRECINCT OVERALL SITE SECTION - d
A-DA-1203 1 : 100
Rev. Date Description Iss. Appr. Do not scale this drawing. Verify all dimensions on site before commencing Project Status Drawing Title
NOOSA MARKETPLACE
any work. Copyright © 2019 Buchan. This drawing remains the property of
1 14.05.19 FINAL ISSUE FOR COMMENT AJ PS
The Buchan Group Australia Pty Ltd. Reproduction in whole or in part without
2 15.05.19 DEVELOPMENT APPLICATION AJ PS prior consent is forbidden. Date Plotted
15/05/2019 11:25:03 PM
File
LOT.1 - SP222982: 2-20 HOFMANN DRIVE, LOT.4 - SP2465848: Date Issued
15.05.19
N MIXED-USE PRECINCT BUILDING
2-18 HOFMANN DRIVE, NOOSA QLD Scale
1 : 100 @A1 SECTIONS
Project Number Drawing Number Revision Brisbane Studio
0 10 20 40 60M
+ 61 7 3859 9222 / buchangroup.com.au
716159 A-DA-1206 2