D E F
5° PITCH TRIMDEK
ROOF SHEETING
8.0m HEIGHT LIMIT AT
ROOF RIDGE
STRATCO EDGE PROFILE GUTTER
WITH FOLDED METAL FASCIA
(STRICTLY NOT CRIMPED LOOK)
RAKED SOFFIT FC SOFFIT
TO BOTTOM CHORD OF TRUSS
FINISHED CEILING HEIGHT
2,750
2,700
Study Master Ensuite Ensuite Balcony 900H RENDERED AND PAINTED DWARF WALL WITH 60mm
(NOM) WIDE POWDER COATED METAL PLATE RAIL OVER (1M
MIN FINISHED HEIGHT) TYPICAL
RECESS IN CONCRETE 200 x 1500mm (nom) CONCRETE
SLAB FOR SHR BEAM TO ENGINEERS DETAILS
(min)
1000
900
R.L. 9.550 TIMBER
1,500
300
GRATED DRAIN
TILES R.L. 9.250 TILES
BALCONY CONSTRUCTION TO
ENGINEERS DETAILS
TO UNDERSIDE OF STUDY SLAB
EXPRESS JOINT TO ACT AS DRIP MOULD
2,575
BULKHEAD ABOVE TO LINE UP WITH
TOP OF SLIDING POCKET DOOR HEIGHT
FINISHED CEILING HEIGHT
3,050
RENDERED AND PAINTED
2,400
2,400
BLOCKWORK (LIGHT COLOUR)
Laundry Kitchen
250 NOM
TIMBER
525
250 NOM
TILES TILES R.L. 6.200
EXPOSED PLUMBING FROM LEVELS ABOVE. PLUMBER TO ENSURE NEAT PIPE PLACEMENT TO BASEMENT CEILING
EXPOSED CONCRETE CEILING
FROM SUSPENDED SLAB
TO UNDERSIDE OF
MPR FLOOR SLAB
GROUND FLOOR SLAB
2,925
TO UNDERSIDE OF
2,650
2,650
2,400
Basement Garage
EXISTING G.L.
ALL INTERNAL BLOCK WALLS
ON SUB LEVEL TO BE SMOOTH
RENDERED AND PAINTED RETAINING WALLS AND DRAINAGE TO
BE STRICTLY IN ACCORDANCE WITH
R.L. 3.550 ENGINEERS DETAILS (LIGHT COLOUR)
HONED / POLISHED CONCRETE
WATER PROOFING TO
ENGINEERS DETAIL
Revision Notes. Project Client Drawing Date Author
reitsma Figured dimensions only are to be taken from this drawing.
All dimensions, bearings, exis ng services, mandatory council
restraints/requirements and proposed levels are to be checked and
verified on site by builder/client prior to commencement of works.
All works must comply with NCC, local authority and all relevant
geographical/wind category requirements. All cut and fill ba ers are
indica ve only and must be established and verified by builder/client
in rela on to proposed slab and/or floor levels
N Wa + Milasas Residence
Lot 524 (#102) Lorikeet Drive
B. Wa + S. Milasas
Builder
Sec on 01b
Stage
29/06/2018
Scale
JTL/MM
Revision
+61 7 5491 6834 13 Ridgewood Road. 1:50 A
Caloundra
Any discrepancies must be communicated to the designer prior to
commencement of works. Please note, builder specifica ons and
These drawings are to be read in conjunc on with other relevant
consultants drawings and reports. Peregian Beach WORKING DRAWINGS -
NOT SUITABLE FOR Project Number Sheet Number
[email protected] QLD, 4551 signed contracts to take precedence over all Reitsma documenta on.
www.reitsma.com.au Australia © Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767 QBCC Lic. No. 1234490 BDAQ Member
Qld 4573 CONSTRUCTION 4422 12 /32
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
33797 MCU app plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.