Amended Plans (17.01.20)
Plans and drawings: the text below has words only, no drawings.
Original PDF page 37, section 1. The text section number identifies this passage in the reader.
LEGEND - Villa 1
QUEENSLAND SMOKE ALARM SYMBOL ITEM NO. OF
REQUIREMENTS AS OF 1/1/17 S Smoke Alarm 8
Smoke alarm devices must not be:
In Summary: * within 300mm of a light fitting MB Meter Box 1
* if installed on a ceiling, within 300mm of a corner of the ceiling and wall GAS Gas Bottle 0
Smoke alarm devices must be installed: * if installed in a staiwell, out of reach of smoke because of an obstruction
* within 400mm of an opening from which air supplied from an air conditioner DW Dishwasher 1
* If practicable, on the ceiling - if the ceiling slopes, it must be in an area of the ceiling that is or force air ventilation within 400mm of the blades of a ceiling fan HW Hotwater 1
between 500mm and 1500mm from the apex of the ceiling. Down light - LED 41
* If installing on the ceiling is not practicable, on an exposed joist or beam that when
measured from the ceiling does not have a depth of more than 300mm when measured Ceiling Fan 7
from the ceiling. Ceiling Fan/light 0
* If these two placements are not practicable, the device can be installed on a wall in an
area that is between 100mm and 300mm from the ceiling and more than 300mm from D Data Point 2
the corner of 2 walls.
PH Phone Point 1
MB TV TV Point 2
HL Exhaust Fan Heat lamp 1
AB - ABOVE BENCH Exhaust Fan/light 3
PH
UB - UNDER BENCH
WP Water proof Dbl PP 2
P Pendant Light- Client supply 1
1400h
D TV
Double Power Point 27
GDO
DN Single Power Point 2
2W Two way 1
S S
3000 LED Strip 0
AB UB
S
Spot light 0
Double spotlight w sensr 1
S Wall light 0
HW
DN
NBN PP Pool Pump Power 1
P A/C Airconditioner - Ducted 1
AC
4000
2w
ay PL GDO Garage Door Opener 1
S POOL
DB WO Wall oven 1
T MW Microwave Single GPO 1
RH Rangehood Single GPO 1
CT Cooktop - Induction 1
PP
NBN Broadband Connection 1
SWP Single Waterproof PP 0
GROUND FLOOR - Villa 1 USB USB Point with GPO 0
ELECTRICAL LAYOUT PL Pool light 1
Single Fluro batten light 2
SCALE 1:100 Niche Star light 0
6.6Kw Solar system 1
Stair wall light 0
S/S up/down light 2
FOR CONSTRUCTION DB Door bell 1
No. Description Date Tracy Dowden - Building Designer Client: Richard & Jodie Thomas
15 Prelim WD's Rev 1 28/10/19 G.F. Electrical Plan Villa 1
9/01/2020 3:39:24 PM
16 Prelim WD's Rev 2 6/11/19 QBCC: 1009413 Description Proposed duplex
17 For Construction WD's 11/11/19 Project number 5VEN
18
19
For Construction WD's Rev 1
For Construction WD's Rev 2
12/12/19
16/12/19
Site Address: 5 Ventura St
Sunrise Beach Qld
Date 22/4/19 A136
Drawn by T.D
20 For Construction WD's Rev 3 19/12/19
QBCC Lic 1184982 21 For Construction WD's Rev 4 9/1/20 Checked by T.D Scale As indicated
THIS DESIGN REMAINS THE COPYRIGHT OF THE DESIGNER.