02.1 - Operational Works Application · OPW18/0008

Attached to the e-mail Operational Works Application OPW18/0008 - Domestic Marine Structure at 6 Mermaid Quay NOOSAVILLE.

of 4

Text shows just the words. Original shows the document exactly as it was published.

   Operational Works Application for Domestic Marine Structure
   (Jetty)
   Site Address:           6 Mermaid Quay, Noosaville
   Property Description:   Lot 120 RP842150
   Reference Documents: Engineering design prepared by HR Design Group
                           Job No: 17-0417, Revision 2 dated 11.12.17
                           Architectural plans prepared by Reitsma Architects
                           Project Number: 4386, Revision C dated 21.12.17


   Table 14-65 Operational Works within Noosa Waters canal
column 1                                                       column 2
Specific Outcomes                               Probable solutions (if code assessment)
14.167 Character and Amenity
O11 Works are designed and sited to ensure— a)        S11.1 For lots with frontages greater than
they are contained within the prolongation of         15m or greater in width, jetties are setback a
boundaries of the lot;                                minimum of 3m from the prolongation of the
b) that when a vessel is berthed it does not          boundaries, except as allowed for in S11.2
    encroach over the prolongation of boundaries of   and S11.3 (Refer Figure 14-34);
    the lot;
                                                      Not applicable – frontage less than 15m
c) a high level of visual amenity is maintained
    when viewed from the watercourse and
    adjoining lands;                                  S11.2 For lots less than 15m in width
d) the works avoid conflicts with uses in the water   (including lots located in canal bends or on
    and on the foreshore and adjoining lands;         lots located in the head of the canal)—
e) materials blend with the natural surrounds;             a) a joint application is made with the
                                                               adjoining owner; Not applicable –
f) cluttering of watercourses is avoided;
                                                               adjoining lots have pre-existing
g) excessive traffic volumes within foreshore
                                                               jetty’s
    areas, on adjoining lands and in the water are
                                                           b) where a joint application is not
    avoided; and
                                                               possible, jetties—
h) they reflect the character and setting of the
                                                           i. are setback a minimum of 1m
    work’s immediate surrounds or the locality
                                                           from the prolongation of the
                                                           boundaries Compliant – see site
                                                           plan
                                                           ii. are not more than 1.5m in width
                                                           generally in accordance –
                                                           additional width of 300mm is minor.
                                                           Review of other existing jetty’s
                                                           within the estate indicates
                                                           numerous examples of jetty’s
                                                           greater than 1.2m in width
                                                           iii. have no jetty head Compliant see
                                                           site plan
                                                           iv. allow for safe access and
                                                           manoeuvrability for both the
                                                           neighbouring property and the subject
                                                           property Compliant see site plan

                                                      S11.3 For lots that adjoin those described in
                                                      S11.2, the jetty is located well away from the
                                                      common boundary Compliant see site plan
Full text of the other 3 pages

Page 2

                  column 1                                        column 2
              Specific Outcomes                    Probable solutions (if code assessment)
14.168 Design, construction and safety – Jetties
O12 Works for jetties are designed and            S12.1 Jetties—
constructed for the sole purpose of providing     a) are a maximum width of 1.5m Compliant;
access to vessels and are sited and designed to
                                                  b) a maximum length of a jetty head is not
avoid—
                                                      more than 7m (Refer Figure 14-35)
a) cluttering of watercourses;
                                                      Compliant see site plan;
b) excessive traffic volumes within foreshore
    areas, on adjoining lands and within the      c) constructed predominately of timber
    watercourse; and                                  Compliant see site plan and
c) unacceptable risks to personal and public          engineering;
    safety;                                       d) are not constructed parallel to the
                                                      revetment wall Compliant see site plan
                                                  e) extend a maximum of 10m past the
                                                      quayline. Compliant


                                                  S12.2 For “Y” and “T” shaped jetty heads or
                                                  other shaped jetty head—
                                                  a)   a maximum area of 10.5m2 excluding any
                                                       walkway is provided Not applicable
                                                  b)   a walkway with a minimum length of 3m is
                                                       provided to the jetty head (Refer Figure
                                                       14-36) Not applicable


                                                  S12.3 Jetties have independent support
                                                  structures and are not supported by the
                                                  revetment wall Compliant see engineering
                                                  design;

                                                  S12.4 The seep holes in the revetment wall are
                                                  not obstructed by any jetty Compliant see
                                                  engineering design;

                                                  S12.5 For lots comprising detached houses or
                                                  duplex dwellings, a maximum of one jetty per
                                                  development is constructed Compliant see
                                                  site plan;

                                                  S12.6 Unit developments with common
                                                  property along canal frontage met the following
                                                  Not applicable

                                                  S12.7 For unit developments where each unit
                                                  has its own individual canal frontage Not
                                                  applicable

Page 3

                    column 1                                           column 2
                Specific Outcomes                       Probable solutions (if code assessment)

                                                        S12.8 Walkways serving jetties have at least
                                                        one rigid handrail fitted and the walkway is a
                                                        minimum width of 750mm and a maximum
                                                        width of 1.5m where—;
                                                         a) the walking surface of the jetty is
                                                              constructed level with the top of the
                                                              revetment wall Compliant see site
                                                              plan and engineering design;
                                                         b) water reticulation systems are fitted
                                                              with a mechanical backflow prevention
                                                              device; and Not applicable
                                                         c) electrical reticulation systems carrying
                                                              electricity in excess of 24 volts are not
                                                              to extend beyond the revetment wall;
                                                              Not applicable

                                                        S12.9 Any lower-level platform, or siding,
                                                        along the jetty walkway has a maximum
                                                        width of 500mm and does not exceed 2m2
                                                        and does not interfere with the prolongation
                                                        of boundaries as indicated by Probable
                                                        solutions 11.1-11.3;
                                                        Not applicable

O13 Pontoons and boat ramps are not constructed in      S13.1 No solution provided
Noosa Waters Estate.

14.169 Boat lifting devices
O14 Boat lifting devices are only constructed in the    S14.1 Boat lifting devices are only located in
absence of a boat ramp and are designed and             conjunction with an approved jetty Not
located to—                                             applicable
a)    ensure that unacceptable risks to personal and
      public safety are unlikely to be caused;          S14.2 Only one boat lifting device and a jetty
b)    avoid cluttering of the watercourse;              hoist per jetty Not applicable
c)    ensure that visual amenity of the foreshore and
      watercourse is maintained; and                    S14.3 A shared jetty containing one boat
d)    ensure the structure integrity of the works are   lifting device on either side of the jetty Not
      maintained and not compromised.                   applicable

                                                        S14.4 The structure may be securely
                                                        attached, excluding roped, chains and
                                                        straps, to an existing jetty where a structural
                                                        engineers report for the design is provided
                                                        certifying that the jetty is structurally capable
                                                        of supporting the boat lifting device Not
                                                        applicable

                                                        S14.5 For twin jetty structures with central
                                                        boat lifting devices- Not applicable

Page 4

                   column 1                                           column 2
               Specific Outcomes                       Probable solutions (if code assessment)
14.170 Fixed Floating Structures & Boat Ramps in Noosa Waters Estate
O15 Fixed floating structures whether or not         No solution provided
attached to land (e.g. pontoons and any associated
walkways) and boat ramps are not located within
the Noosa Waters Estate.
14.171 Flooding and amenity functions
O16 The flood and amenity functions of areas         S16.1 No building works, filling or excavation
adjacent to the revetment walls within Noosa         works are within 4.5m of the centre line of the
Waters Estate are retained and enhanced by           top of the concrete revetment wall Not
ensuring—                                            applicable;
a) works do not protrude through a batter line of
    1:4.5 measured from the centre line of the       S16.2 A minimum of 25% of the area within
    revetment wall;                                  4.5m of the revetment wall is planted with
b) there is no additional load placed on the         shrubs and trees with a mature height of 3m or
    revetment wall;                                  less Not applicable
c) the amenity of the locality is not adversely
    affected by the building works, filling or       S16.3 A maximum of 25% of the area within
    excavation works or improvements.                4.5m of the revetment wall is under hard
                                                     pavement, decking or similar and the balance is
                                                     to be grass, ground covers or shrubs provided
                                                     no shrubs are planted within the first 1m of the
                                                     revetment wall Not applicable

                                                     S16.4 The ground surface within the first metre
                                                     of the revetment wall is grass or ground cover
                                                     Not applicable

                                                     S16.5 No tree species with a mature height of
                                                     over 3m are planted within 4.5m of the
                                                     revetment wall Not applicable

Used in these records

About this file

File size
96 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

02.1 - Operational Works Application.pdf · 96 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.