Murray - Structural Design Advice · OPW18/0056

Attached to the e-mail Operational Works Appliction – Prescribed Tidal Works - 17 Wesley Ct Noosa Heads.

of 2

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

SUNSHINE COAST OFFICE

Level 4, 45 Brisbane Road Mooloolaba Qld — PO Box 102 Mooloolaba Qld 4557
T: 07 5477 6437 F: 07 5444 4216 E: [email protected]

 

EMP

ENGINEERING CORAL COAST OFFICE

9 Princess Street Bundaberg Qld PO Box 2052 Bundaberg Qld 4670
T: 07 4154 4894 F: 07 4154 4274 E: [email protected]

 

ACN: 112 761510 ABN: 21112761510

In reply please refer to:
Our: Troy Paulsen

At: Sunshine Coast
Our Ref: SC-7000-117

1% February 2018

The Manager

The Jetty Specialists Pty Ltd
2 Industrial Avenue
Caloundra QLD 4551

Dear Sir,

Structural Design Advice

Project: Proposed Pontoon, Piles and Catwalk
Client: NT & DE Murray
Address: Lot 40 (17) Wesley Court Noosa Heads

We, Empire Engineering Pty Ltd, advise that the proposal to construct the works described above
has been checked by us. When the works are constructed in accordance with the approved
drawings and in the location shown, the proposed works are structurally adequate for the
anticipated usage in this location and should comply with the design and safety provisions of the
Prescribed Tidal Works Code (Schedule 3 of the Coastal Protection and Management Regulation
2017), based on the design criteria and assumptions listed below:

Basis of Design Advice

e The works do not impose loads that would significantly affect existing structures.

e The works do not adversely affect the stability of the bed and banks in the near
vicinity of the structure.

e Pontoon identification to comply with Schedule 3 of the Coastal Protection and
Management Regulation 2017

e Structural design criteria:

Maximum Wave Height 400mm wind wave
300mm boat wake

Wind Classification N3

Maximum Current 1.5 m/s parallel to face of pontoon

Scour Reasonable scour effects from flood flows and tidal flows have
been considered

Debris Load To AS3962

Impact Load Minor loads without some damage to the structure

Max Vessel Size Berthed 16.6m length, 4.5m beam
Full text of the other 1 page

Page 2

Relevant Codes AS1170, AS3962 and AS3600, except where varied by the
Prescribed Tidal Work Code

Tethering System To be provided, where a tidal water level change resulting
from a 1% probability flood event results in pontoon detaching
from piles.

The design advice does not cover the construction or installation of the works on site. The
builder shall confirm the adequacy of the site conditions during installation and shall advise
the Engineer if variation from details shown on the drawings occur. No detailed site
investigation or studies have been carried out by us or provided to us. The design review
has been carried out on the basis of limited enquiry only. Pile depths shown are applicable if
founding in stiff clay or dense sand. There is some additional risk of failure should the
above design criteria be exceeded, or actual site conditions be inferior to those assumed. If
ground conditions other than those described above are encountered during construction or
seabed levels encountered are deeper than those shown on the drawings, further advice
should be sought.

This design advice relies on designs prepared by other consultants, but does not warrant
them.

The structure is to be built in accordance with the following referenced documentation,
using good building practice.

Referenced Documentation

e Drawing No. JSP-SJ-29030 Issue B
e Drawing No. JSP-SJ-29031 Issue A

Competent Person Details

Name: Troy Paulsen REPQ: 6990
Name of firm for and on behalf person is signing:

Empire Engineering

Level 4/ 45 Brisbane Road
(PO Box 201)

Mooloolaba Qld 4557

a

Troy Paulsen
For and on behalf of
EMPIRE ENGINEERING Pty Ltd

 

Used in these records

About this file

File size
486 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Murray - Structural Design Advice.pdf · 486 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.