Residence Carparking
Attached to the e-mail MCU16/0144 - Information Response.
REAL PROPERTY DESCRIPTION
Storm Water
Lot: 63 On: RP200339 Surface water drainage must be prevented from
Lot / Site Area (m²): 10080 m² entering the building with fgl sloping 50mm over
Local Government: Noosa Shire Council the first 1m away from the building & the finished
slab height at a minimum FFL 150mm above FGL or
STATUTORY INFORMATION:
minimum 100mm above FGL in sandy, well drained
Building Classification: 1a areas of low rainfall intensity (Q20 125mm), or 50mm
Storeys: 1 above impermeable paved or concreted areas all
Climate Zone: 5 in accordance with BCA Vol 2 P3.1.2.3
Wind Category: N3
Dr
Carpark to Cafe Domestic driveway design requirements :
General • 3m minimum width (AS 2890:2004 Amdt1, S2.6.1)
at e
Do not scale from these drawings, figured • Maximum 1 in 4 (25%) gradient (AS 2890:2004
sg
dimensions take precedence at all times - Amdt1, S2.6.2)
ing
when in doubt consult the designer prior to
K
commencing construction. It is the Changes in grade for straight driveways to prevent
builders responsibility to: vehicle scraping driveway require grade transitions
Existing Cafe of 2m in length when:
• Verify all dimensions and levels on site. • Summit changes in grade is over 1 in 8 (12.5%)
• Ensure all boundary setbacks are strictly • Sag changes in grade is over 1 in 6.7 (15%)
adhered to. (AS 2890:2004 Amdt1, S2.5.3(d)
• Verify location and levels of all services on site.
• Verify that floors and finished levels enable Builder is to follow the best practice
Existing Crossover and
connection to required services on site. guidelines for controlling stormwater
Gravel Driveway
pollution from building sites by local council
Su
• Real property information to be confirmed by
licensed surveyor prior to construction. Residence
• Bearings have been corrected by modelling The builder is responsible to check all existing
nri
software to read in a clockwise direction. services prior to beginning construction
This may cause discrepancies of 180 deg from Carparking for existing residence
original survey information.
se
• Site levels, driveway design & site works to
detail by others.
Carparking for Ancillary Dwelling
These drawings have been prepared for building Drawing Schedule
Rd
permit application only. It is the builder's / proprietor's
responsibility to further interpret the design and Current Revision
drawings to detail the project for construction. Existing Structure Sheet No. Sheet Name Revision Date
Termites A.01 SITE PLAN
Protection against subterranean termites to be
A.02 FLOOR PLAN
in accordance with A.S. 3660 Part 1. (protection
of buildings from subterranean termites). A.03 ELEVATIONS
Protection against subterranean termites to
apply to all "primary building elements".
The builder is to provide physical barriers to
the entry by subterranean termites by
construction of all slabs & timber floor framing in
accordance with A.S. 2870.1 (Residential footing
and slab construction). and A.S. 3600 (Concrete
structures code). In addition all slab penetrations
are to be protected using stainless steel mesh.
(Termimesh or equivalent fitted to manuf. spec.).
External perimeter barrier to be installed by
excavation trenches, treating the exposed
trench and backfilling the trench with treated
material and protecting the trench with a
50mm thick concrete cover strip x 300mm
wide measured from the external wall of the
building. 2 durable notices shall be installed
in prominent locations stating method of
protection, date of installation, life expectancy
and scope and duration of future inspections.
Regular inspections of the building are to be
carried out to ensure the barrier has not
been bridged by termites.
Inspections are to be carried out as per notices.
SITE PLAN
Scale 1 : 1000
AS CONTRUCTED RESIDENCE
A.01
0 1m 2m 4m 6m 8m 10m
SCALE @A3
ZEST BUIDLING DESIGN STUDIO Project Address Drawing Title
SITE PLAN
1:200
Sunshine Coast 1 Kingsgate Drive Orange on
Sunrise TINBEERWAH 4563
P | 0457314346
A | 30 Wattlebird Drive, Doonan, QLD 4562
E | [email protected]
W | www.zestbuildingdesign.com.au
16072
ABN: 37 601 151 508
Q.B.C.C Lic. No: 1307012 Client Name
RG Strategic
Phase Bld # Issue
AC 00
Designer (s)
I. Brundell
Issue Description Date
AS CON
Original sheet size A3 (297x420) Plot date: 11/11/2016 5:19:27 PM