Council archive · source document
190812 - Noosa Council Amendment Request MCU 180001 · MCU18/0001.01
Attached to the e-mail FW 8 Stevens St Sunshine Beach MCU180001.msg.
Very large file (12.1 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Noosa Council documents
c. be fitted with a fixed external screen
12. To ensure privacy doors, windows, glazing or balconies that have the potential to overlook
the private spaces of neighbouring properties must include either balustrading or fixed
external screens, positioned in such a way to obscure direct views into the habitable room
windows or private open space areas of the adjoining property.
Site Access and Driveways
13. A sealed access driveway must be provided from the existing formation in the shared
driveway to all parking and manoeuvring areas of the development.
14. All vehicle movements associated with entering and exiting the development must be
undertaken wholly within the property or the associated access easements.
15. Vehicle manoeuvring must be in accordance Australian Standards and Engineering
Certification dated 13 November 2018 as authored by Bax Engineering Pty Ltd.
16. Certification from a RPEQ that vehicle manoeuvring is in accordance with Condition 15 is
required to be submitted to Council when construction is complete and prior to the Final
Building Inspection Certification is issued.
Fencing and Walls
17. Any street fencing must be in accordance with the approved plans and the area of land
between the fence and the front property boundary must be densely landscaped to screen
any fencing from the street.
Setbacks
18. The balustrading on the deck shown on the Ground Floor Plan C2.0 on the northern and
eastern boundary must be setback 1.5 metres from the edge of the structure (planter) and
be densely landscaped (in accordance with the approved plans) to prevent overlooking
opportunities into adjoining property.
19. The setback of the sundeck on the upper level plan must be setback a minimum of 5.2 metres
from the rear boundary and be in accordance with the approved plans.
Garage
20. The garage wall height must not be any higher than indicated on Elevation Plans no. C4.0
and C5.0.
Stormwater Drainage
21. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property. The works must be undertaken
generally in accordance with the “Stormwater Quantity Assessment” prepared by BAX
Engineering reference 018-001 Clout Design dated 26 June 2018.
Easements
22. No part of the structure or roof line is to encroach on the access easement. Certification
must be submitted to Council from a Licensed Surveyor which certifies that the building does
not encroach on the any access easement.
23. Emt B on SP279875 at the rear of the site must be deleted upon completion of works.
24. Unless otherwise agreed in writing by the relevant service provider, any public or third party
infrastructure located on the subject site must be placed within an easement registered
against the title of the property.
25. All easements must be designed in accordance with the planning scheme and granted at no
cost to the Grantee. Where the Grantee is Council or a service authority, the easement
documentation must be in accordance with the Grantee’s standard easement terms. Draft
easement documentation must be submitted to Council for endorsement.
Page 3 of 7
Document Set ID: 20738719
Version: 4, Version Date: 22/11/2018 Print Date: 22 November 2018, 12:40 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
190812 - Noosa Council Amendment Request MCU 180001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.