Council archive · source document
190812 - Noosa Council Amendment Request MCU 180001 · MCU18/0001.01
Attached to the e-mail FW 8 Stevens St Sunshine Beach MCU180001.msg.
Very large file (12.1 MB): the original may take a few minutes to open or download. The page text below is quick to read.
ROOF STRUCTURE TO ENGINEER'S DESIGN & DETAIL (TED) - REFER TO SCHEDULES FOR FINISHES ANGLE TOP OF FRAMED WALL TO FOLLOW STAIR SLOPE - FINISH 1000 MIN ABOVE STAIR SLOPE
DINCEL WALLS TO ENGINEER'S DESIGN & DETAIL (TED) BLOCK WALLS TO ENGINEER'S DESIGN & DETAIL (TED)
ENSURE WATERPROOFING TO LOWER FLOOR EXTERNAL WALLS TO MANUFACTURER'S SPEC & SUSPEDED CEILING - REFER TO FRLECTED CEILING PLAN
COMPLIES WITH AUSTRALIAN STANDARDS & BUILDING CODES
RETAINING TO ENGINEER'S DESIGN & DETAIL (TED)
BUILDING SURROUND & STRUCTURE TO ENGINEER'S DESIGN & DETAIL (TED)
SUSPENDED CONCRETE SLAB & UPTURN BEAMS TO ENGINEER'S DESIGN & DETAIL (TED)
TERMITE BARRIER TO BCA3.1.3 200UM WATERPROOF MEMBRANE TREATMENT AGAINST TERMITE ATTACH
FEATURE AWNING TO ENGINEER'S DESIGN & DETAIL (TED)
8m HEIGH
5.0° T LIMIT
5.0°
RH
UPPER FLOOR PP RL 34205 UPPER FLOOR PP RL 34205
W16 820D D13
D10
FRONT SETBACK
BOUNDARY
2400
LINEN STAIRS MASTER 2 ROBE MASTER 2
2330
UPPER FLOOR RL 31875 RL 31875 RL 31875 UPPER FLOOR RL 31875
600
GROUND FLOOR CEILING RL 31275 GROUND FLOOR CEILING RL 31275
BOUNDARY
W12
SCREEN 2 720D
2800
PDR PANTRY KITCHEN
TOW RL 29220
NATURAL GROU
ND LEVEL
GROUND FLOOR RL 28475 RL 28475 RL 28475 GROUND FLOOR RL 28475
300
LOWER FLOOR CEILING RL 28175 LOWER FLOOR CEILING RL 28175
SCREEN 1 GD1
2700
TOW RL 26805 VOS
NATURAL GROU
2200
ND LEVEL
GARAGE FLOOR RL 25665 GARAGE FLOOR RL 25665
190
LOWER FLOOR RL 25475 LOWER FLOOR RL 25475
SECTION 3
SCALE: 1 : 100
FEATURE AWNING TO ENGINEER'S DESIGN & DETAIL (TED) ROOF STRUCTURE TO ENGINEER'S DESIGN & DETAIL (TED) - REFER TO SCHEDULES FOR FINISHES
CONCRETE POOL SHELL TO ENGINEER'S DESIGN & DETAIL SUSPENDED CONCRETE SLAB & UPTURN BEAMS TO ENGINEER'S DESIGN & DETAIL (TED)
(TED) - REFER TO SCHEDULES FOR FINISHES
SUSPEDED CEILING - REFER TO FRLECTED CEILING PLAN
SUSPENDED CONCRETE SLAB TO ENGINEER'S DESIGN & DETAIL (TED)
DRIVEWAY & DRAINAGE TO ENGINEER'S DESIGN & DETAIL (TED)
SUSPEDED CEILING - REFER TO REFFLECTED CEILING PLAN
ALL FOOTINGS TO ENGINEER'S DESIGN & DETAIL (TED)
ROOF STRUCTURE TO ENGINEER'S DESIGN & DETAIL (TED) - REFER TO SCHEDULES FOR FINISHES
TERMITE BARRIER TO BCA3.1.3 200UM WATERPROOF MEMBRANE TREATMENT
DINCEL WALLS TO ENGINEER'S DESIGN & DETAIL (TED) AGAINST TERMITE ATTACH
BLOCK WALLS TO ENGINEER'S DESIGN & DETAIL (TED) 8m HEIGHT LIMIT BOUNDARY WALLS TO ENGINEER'S DESIGN & DETAIL (TED)
2.0° 8m HEIGHT LIMIT
UPPER FLOOR PP RL 34205 UPPER FLOOR PP RL 34205
920CSD D10 D9 SCREEN 5
D13 W25 D12
SCREEN 6
2330
STAIRS
TERRACE
SIDE SETBACK
SIDE SETBACK
SIDE SETBACK
SIDE SETBACK
BOUNDARY
BOUNDARY
BOUNDARY
BOUNDARY
UPPER FLOOR RL 31875 RL 31875 UPPER FLOOR RL 31875
TOW RL 31825
600
GROUND FLOOR CEILING RL 31275 GROUND FLOOR CEILING RL 31275
W12 620CSD D5
W8 W7 D4
2800
HALL KITCHEN DINING LIVING
RL 29220
GROUND FLOOR RL 28475 RL 28475 RL 28525 RL 28475 RL 28400 GROUND FLOOR RL 28475
300
LOWER FLOOR CEILING RL 28175 LOWER FLOOR CEILING RL 28175
TBC
SCREEN 1
PW2
POOL PW3 GARAGE DOOR
MAX 1.35 HEIGHT MOTOR SIZE TBC
GD2 GD1 820D
TOP OF CAPPING MAX RL 27175 RL 26965
2700
NATURAL GROUND LEVEL GARAGE
HALL
600 850 40
FINSHED GR
OUND LEVEL
GARAGE FLOOR RL 25665 RL 25665 GARAGE FLOOR RL 25665
190
RL 25475
LOWER FLOOR RL 25475 LOWER FLOOR RL 25475
SECTION 4 SECTION 5
SCALE: 1 : 100 SCALE: 1 : 100
CLIENT: Judy & Michael KLOBAS PROJECT: PIPIS
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot 696 on SP279875 8 Stevens Street Sunshine Beach QLD 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: SECTION
P: (07) 54748 107 be read in conjunction with engineers design and details, the
DATE: 08/08/19 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
F: (07) 54748 108 BSA LICENCE: 1127508
accompanying building specification and schedule of finishes. If in
doubt, please request clarification. DO NOT ASSUME. ISSUE: WORKING DRAWINGS FOR CONSTRUCTION
WD6.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
190812 - Noosa Council Amendment Request MCU 180001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.