24.083_Seamount Quay_Issue B_16Jan25
drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: BRETT & KIM GOSCHEN
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
Address: No. 22 SEAMOUNT QUAY, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 91 ON RP842151 DRAWING NAME REV DATE
COVER SHEET B 16/01/25
A3
DESIGNER PROJECT NO
SD KUNKEL 24.083
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
5. Do not scale off drawings, use figured dimensions
Projected only. Any dimensions not nominated must be referred to
bou ndary the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
1500 wate
r allocation property details
boundary
1.825m
17°40'0"
No. 22 Seamount Quay
Noosaville QLD 4566
15000
Noosa Shire Council
(43.000m Locality - Noosaville
) Lot 91 on RP842151
13°35'40"
107°40'0"
Site Area - 866m²
Zone - Low Density Residential
water allocation area Overlays - Acid Sulphate Soils
- Flood Hazard
Existing revetment wall - Coastal Hazard
c an al
11.358m
q u ay
9678 from bdy
197°40'0"
Existing jetty to
be removed
11.358m
em t l
proposed
o unt
jetty
from screw in revetment wall - confirm
9797 from bdy
14.658m
10000 from revetment wall
se am
7100 from bdy
7105
5°27'10"
187°29'25"
2.000m
1500 water allocation boundary
Projected boundary (40.862m) 96°54'20"
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 BRETT & KIM GOSCHEN NEW JETTY SITE PLAN 01 B 24.083 A3
NORTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
No. 22 SEAMOUNT QUAY, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
B 16/01/25 SDK CONSTRUCTION ISSUE Lot 91 ON RP842151 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
notes
1. Contractor to confirm exact siting and orientation
Boundary
Boundary
prior to construction setout.
aluminium framing sizes to engineers 2. All building setout & confirmation of setbacks &
height to be carried out by a Licensed Surveyor.
10000 design & detail
3. Do not scale off drawings, use figured dimensions
1150 2100 6750 575 575 only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
4550 2000 200 1125 1725 2850 2850 875 dimensions on site prior to construction.
315 dia. pvc insitu piles
to engineers detail 4. Levels & services locations to be confirmed prior to
construction.
725
5. Termite protection to be provided in accordance with
1150
140x25 composite decking clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
Contractor to provide protection information for building
Existing development application.
2700
Existing 300mm deep fascia revetment wall legend
revetment wall Denotes dimension to centre line
2100
2000l x 425w Joists to butt into headstocks 2000l x 425w
4700
3250
kayak step with site welded connection kayak step Denotes dimension to outside face
725
2000
Do not fix jetty
jetty
1450
to revetment wall
725
725
2000l rigid handrail to Do not fix jetty
comply with Noosa 575 2850 2850 2850 875 to revetment wall
Shire Council regulations
10000
200x50x3mm aluminium 2/152x65x6mm structural
floor joists @ 450mm crs max. 'c' channel headstocks per pile
floor plan floor framing & footing plan
1 1 : 100
2 1 : 100
2000
200 200
200
powdercoated
Boundary line
2/152x65x6mm structural aluminium handrail
'c' channel headstocks per pile 140x25 composite decking
200x50x3mm aluminium Floor joists site welded to Do not fix jetty to
floor joists @ 450 crs max. headstocks to engineers detail revetment wall
140x25 composite decking
300mm deep composite 300mm deep fascia
decking fascia to perimeter
Existing revetment wall typical handrail detail
Headstocks to piles to
engineers detail
4 1 : 50
315 dia. pvc insitu piles
to engineers details floor areas
jetty area 20.4 m²
total area 20.4 m²
signatures
owner/s
section
3 1 : 50
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 BRETT & KIM GOSCHEN NEW JETTY FLOOR PLAN, FLOOR FRAMING PLAN & 02 B 24.083 A3
NORTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
No. 22 SEAMOUNT QUAY, NOOSAVILLE Q 4566 TYPICAL SECTION SHEETS IN SET SCALE
B 16/01/25 SDK CONSTRUCTION ISSUE Lot 91 ON RP842151 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies