Original source · versioned page text
221010 - Seaview Tce - Increased Northern Setback
A B C D E F G site details
60 and 66 Seaview Tce,
LOT 4 Sunshine Beach QLD 4567
RP189884
Lot 96 on RP 81810
annel
public walkway Site Area 576 sqm
and ch
site boundary | 24.635 m approx | 94° 20' 40"
areas
te kerb
concre
proposed new dwelling
2.0m setback
lower ground
internal 178.70 m²
1 se
site boundary | 22.183 m approx | 4° 20' 40"
external - pav 26.40 m²
external - pool 23.15 m²
k
LOT 51
costal set bac
sub total 228.25 m²
RP81810
ground floor
internal 259.93 m²
Terrace
LOT 69
external 26.90 m²
RP81810
site bounda
external - pav 27.19 m²
proposed 2 sub total 314.02 m²
story dwelling
ry | 22.34
2 level 01
Seaview
internal 12.15 m²
8 m appro
external 78.25 m²
sub total 89.75 m²
x | 177° 21'
3 subtotal internal 450.78 m²
subtotal external 181.89 m²
50"
proposed new
total 632.67 m²
driveway
site cover
proposed new
stormwater max 40% = 230.43 m²
connection
lower ground 219.6 m² / 38.12%
4 proposed new
sewer connection
2.0m setback ground floor 230.16 m² / 39.95%
level 01 29.8 m² / 5.17%
10.5m coa
elec pillar sewer pump out line
proposed electrical site boundary | 27.345 m approx | 274° 20' 40"
2.0m setback
stal setback
connection to new dwelling
elec
power pole notes
LOT 68
RP81810 1. All works to be carried out in
FFL 35.750 accordance with the general
roof ridge approx construction notes on coversheet of this
package.
2. All works to be carried out in
accordance with the DA and BA
including drawings & conditions.
3. Areas measured to outside face of
walls. External covered area
calculations do not include external
areas under eaves, driveway and
uncovered hardscaping.
legend
existing sewer line
existing stormwater line
existing electrical line
existing telephone
existing water line
note: refer survey for all existing services
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
H
I
21.06.22
19.08.22
DA Comparison
DA RFI Response
66 Seaview Tce, G & C Deane site plan SD 100.00 K SCALE As
indicated
proposed site plan
JB J 01.09.22 DA Approval Set
Sunshine Beach
JB K 10.10.22 Increased Northern setback schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 10 pages
Page 2
A B C D E F G
2450 2760 4990
3000
site boundary | 24.635 m approx | 94° 20' 40"
3000
3622
swimming pool under
3622
2.0m setback
1
line of awning over
facade screen
3050
site bounda
k
k +3m
coastal setbac
1
coastal setbac
facade screen
400.02
ry | 22.34
site boundary | 22.183 m approx | 4° 20' 40"
6660
outdoor room under
8 m approx
| 177° 21
planted
roof over
scooter
' 50"
store roof over
2 glass balustrade
1 stone
400.01
crockery/ d/w bar fridges
3220
glassware mwave under firepit
sk fridge
up
art
3
powder A/C HWU
services
pebble
6580
roof
1
400.00 solar
array
skl01
4 2.0m setback
2100
site boundary | 27.345 m approx | 274° 20' 40"
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
F
G
21.06.22
19.08.22
DA Comparison
DA RFI Response
66 Seaview Tce, G & C Deane floor plan SD 200.02 I SCALE 1 : 100
level 01
JB H 01.09.22 DA Approval Set
Sunshine Beach
JB I 10.10.22 Increased Northern setback schematic design
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
1:1 @ A3
Page 3
A B C D E F G
2450 2760 4990
3000 3000
site boundary | 24.635 m approx | 94° 20' 40"
3622
2.0m setback
1
site bounda
k
k +3m
coastal setbac
1
coastal setbac
400.02
ry | 22.34
site boundary | 22.183 m approx | 4° 20' 40"
void
6660
8 m approx
| 177° 21
' 50"
fire pit under
solar
array
2
1
400.01
3220
proposed roof shaded grey
3
6580
1
400.00
4 2.0m setback
2100
site boundary | 27.345 m approx | 274° 20' 40"
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
F
G
21.06.22
19.08.22
DA Comparison
DA RFI Response
66 Seaview Tce, G & C Deane floor plan SD 210.00 I SCALE 1 : 100
roof plan
JB H 01.09.22 DA Approval Set
Sunshine Beach
JB I 10.10.22 Increased Northern setback schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 4
A B headland
C
57m
68
sunshine
fsl 33150
solid wall beach
existing
screening tree
headland view
obscured view
towards N-NW
fsl 33250
69
Terrace
public walkway
site boundary | 22.183 m approx | 4° 20' 40"
landscaped zone
hob 37920
tow 39270
privacy screen in landscape beach
Seaview
proposed planter screening view
67 66
2.0m setback
65 64 A B C
1 10 - site context plan
1 : 400
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
C
D
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-01 F SCALE 1 : 400
neighbour amenity study - context plan
JB E 01.09.22 DA Approval Set
Sunshine Beach
JB F 10.10.22 Increased Northern setback schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 5
existing screening tree
existing screening tree
rooftop viewshed - current application aerial photo
proposed planter screening
tow 39270 no view
tow 38290
screen
rooftop viewshed - additional planter and boundary tree angled privacy screen diagram
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
C
D
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-02 F SCALE 1 : 10
neighbour amenity study - perspectives
JB E 01.09.22 DA Approval Set
Sunshine Beach
JB F 10.10.22 Increased Northern setback schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 6
existing screening tree
master suite / pool viewshed - current application - no overlooking
existing screening tree
additional screen and
landscaping
master suite / pool viewshed - additional planter and boundary tree - no overlooking
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
C
D
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-03 F SCALE
neighbour amenity study - perspectives
JB E 01.09.22 DA Approval Set
Sunshine Beach
JB F 10.10.22 Increased Northern setback schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 7
additional screen and
landscaping
greenspace viewshed of rooftop screening and landscape - 8m high canopy buffer is
proposed by use of a 1m wide planting strip zone.
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
B
C
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-04 E SCALE
neighbour amenity study - greenspace
JB D 01.09.22 DA Approval Set
Sunshine Beach
JB E 10.10.22 Increased Northern setback screening schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 8
public beach access
No 66 boundary
No 66 boundary
No 68 boundary
1m
landscape zone
1 topographical section a
1 : 200
public beach access
No 66 boundary
No 66 boundary
No 68 boundary
3m
privacy screen in landscape
proposed new planter
1 .4m
existing greenspace not visible from roof
1m
landscape zone
2 topographical section b
1 : 200
topography modelled from council records
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
C
D
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-05 F SCALE 1 : 200
neighbour amenity study - topographical
JB E 01.09.22 DA Approval Set
Sunshine Beach
JB F 10.10.22 Increased Northern setback sections schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 9
existing tree canopy
privacy screen in landscape
proposed new planter
No 68
1m
No 66
landscape zone
1 topographical section c
1 : 200
topography modelled from council records
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
C
D
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-06 F SCALE 1 : 200
neighbour amenity study - topographical
JB E 01.09.22 DA Approval Set
Sunshine Beach
JB F 10.10.22 Increased Northern setback sections schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 10
"Exground pandanus stock in a ‘fan’ shape - Install is typically by crane. a hundred tonne crane would normally be able to manage a tree of this size out
to about 20-30m" - Marc Conlon, Director Conlon Group (Landscape Architects)
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
A
B
18.08.22
19.08.22
Revised Neighbour Amenity
DA RFI Response
66 Seaview Tce, G & C Deane 910-07 D SCALE
neighbour amenty study - exemplar
JB C 01.09.22 DA Approval Set
Sunshine Beach
JB D 10.10.22 Increased Northern setback screening tree schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 11
4.50°
reference - "metric handbook person standing"
1400 angled screen
1635 eye height
balustrade
planter
3050
angled privacy screen height diagram
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
A
B
19.08.22
01.09.22
DA RFI Response
DA Approval Set
66 Seaview Tce, G & C Deane 910-08 C SCALE 1 : 15
privacy screen section
JB C 10.10.22 Increased Northern setback
Sunshine Beach schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.