221010 - Seaview Tce - Increased Northern Setback
A B C D E F G site details
60 and 66 Seaview Tce,
LOT 4 Sunshine Beach QLD 4567
RP189884
Lot 96 on RP 81810
annel
public walkway Site Area 576 sqm
and ch
site boundary | 24.635 m approx | 94° 20' 40"
areas
te kerb
concre
proposed new dwelling
2.0m setback
lower ground
internal 178.70 m²
1 se
site boundary | 22.183 m approx | 4° 20' 40"
external - pav 26.40 m²
external - pool 23.15 m²
k
LOT 51
costal set bac
sub total 228.25 m²
RP81810
ground floor
internal 259.93 m²
Terrace
LOT 69
external 26.90 m²
RP81810
site bounda
external - pav 27.19 m²
proposed 2 sub total 314.02 m²
story dwelling
ry | 22.34
2 level 01
Seaview
internal 12.15 m²
8 m appro
external 78.25 m²
sub total 89.75 m²
x | 177° 21'
3 subtotal internal 450.78 m²
subtotal external 181.89 m²
50"
proposed new
total 632.67 m²
driveway
site cover
proposed new
stormwater max 40% = 230.43 m²
connection
lower ground 219.6 m² / 38.12%
4 proposed new
sewer connection
2.0m setback ground floor 230.16 m² / 39.95%
level 01 29.8 m² / 5.17%
10.5m coa
elec pillar sewer pump out line
proposed electrical site boundary | 27.345 m approx | 274° 20' 40"
2.0m setback
stal setback
connection to new dwelling
elec
power pole notes
LOT 68
RP81810 1. All works to be carried out in
FFL 35.750 accordance with the general
roof ridge approx construction notes on coversheet of this
package.
2. All works to be carried out in
accordance with the DA and BA
including drawings & conditions.
3. Areas measured to outside face of
walls. External covered area
calculations do not include external
areas under eaves, driveway and
uncovered hardscaping.
legend
existing sewer line
existing stormwater line
existing electrical line
existing telephone
existing water line
note: refer survey for all existing services
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0375
JB
JB
H
I
21.06.22
19.08.22
DA Comparison
DA RFI Response
66 Seaview Tce, G & C Deane site plan SD 100.00 K SCALE As
indicated
proposed site plan
JB J 01.09.22 DA Approval Set
Sunshine Beach
JB K 10.10.22 Increased Northern setback schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.