Original source · versioned page text
Appendix E - Noosa Plan 2020 Assessment
Performance Outcome Acceptable Outcome Response
Please refer to the
Architectural Plans included in
Appendix F for further details.
Site Cover AO12 Complies
Site cover for a dwelling house,
PO12 The development has a site
does not exceed 40% of the
Site cover of development cover of 35%.
site area
does not exceed—
Alternative provision to QDC
a) 45% where atleast
75% of units are small Editor’s note – any structure
dwellings and a greater than 1 metre above around
minimum of 10% of the level will contribute to site cover
total GFA is affordable such as balconies, patios, decks,
rental premises; or above ground swimming pools and
the like.
b) 40% otherwise
Editor’s note – Where the site is
included in more than one zone,
site cover calculations are for that
part of the site in the Medium
density residential zone only.
Editor’s note - Where a property is
included in more than one zone,
for example in the Medium density
residential zone and the
Environmental Management and
Conservation Zone, only the
portion in the Medium density
residential zone is considered
when calculating site cover, as the
portion in the Environmental
Management and Conservation
Zone contributes nothing to
development yield.
Plot Ratio AO13 Not Applicable
Plot ratio for a dwelling housing
PO13 The development does not
does not exceed 0.4:1
Plot ratio of development does involve a dwelling house.
not exceed: