Original source · versioned page text
Appendix E - Noosa Plan 2020 Assessment
Performance Outcomes Acceptable Outcomes Response
AO6.5 Not Applicable
Basements and underground
The development does not
car parking areas are
involve basement or
designed to drain and
underground car parking areas.
function safely during a flood
event and power failure.
Editor's note—Basements
should have flood immunity
above the 1%AEP defined
flood event with alternative
means to mechanical
pumping used to achieve
such immunity.
Disaster management
PO7 AO7.1 Complies
Development supports, and Development is located to
The development involves a
does not unduly burden, support self-evacuation of
two-storey townhouse typology
disaster management people and ensure sufficient that allows for self-evacuation
response or recovery capacity warning time for the nature of of people to the street frontage.
or capabilities. the use.
AO7.2 Complies
Development does not: The development results in a
decreased number of people
a) increase the number of calculated to be at risk from
people calculated to be flooding or in need of
at risk from flooding; evacuation.
b) increase the number of The development does not
people likely to need result in shortened flood
evacuation; warning times for other uses or
c) shorten flood warning impact on the ability of traffic to
times for other uses in use evacuation routes.
the floodplain; or
d) impact on the ability of
traffic to use
evacuation routes, or
unreasonably increase
traffic volumes on
evacuation routes.
5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Appendix E - Noosa Plan 2020 Assessment.pdf)