Skip to the record
The only place to find full transcripts.

Original source · versioned page text

Appendix B - Geotech and Acid Sulfate report - MCU19-0030

of 67

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Internal Quality Control Review and Glossary

General
1.    Laboratory QC results for Method Blanks, Duplicates, Matrix Spikes, and Laboratory Control Samples are included in this QC report where applicable. Additional QC data may be available on
      request.
2.    All soil results are reported on a dry basis, unless otherwise stated.
3.    All biota/food results are reported on a wet weight basis on the edible portion, unless otherwise stated.
4.    Actual LORs are matrix dependant. Quoted LORs may be raised where sample extracts are diluted due to interferences.
5.    Results are uncorrected for matrix spikes or surrogate recoveries except for PFAS compounds.
6.    SVOC analysis on waters are performed on homogenised, unfiltered samples, unless noted otherwise.
7.    Samples were analysed on an 'as received' basis.
8.    This report replaces any interim results previously issued.


Holding Times
Please refer to 'Sample Preservation and Container Guide' for holding times (QS3001).
For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the SRA.
If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.
Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.
For VOCs containing vinyl chloride, styrene and 2-chloroethyl vinyl ether the holding time is 7 days however for all other VOCs such as BTEX or C6-10 TRH then the holding time is 14 days.
**NOTE: pH duplicates are reported as a range NOT as RPD


Units
mg/kg: milligrams per kilogram                                           mg/L: milligrams per litre                                             ug/L: micrograms per litre
ppm: Parts per million                                                   ppb: Parts per billion                                                 %: Percentage
org/100mL: Organisms per 100 millilitres                                 NTU: Nephelometric Turbidity Units                                     MPN/100mL: Most Probable Number of organisms per 100 millilitres


Terms
Dry                             Where a moisture has been determined on a solid sample the result is expressed on a dry basis.
LOR                             Limit of Reporting.
SPIKE                           Addition of the analyte to the sample and reported as percentage recovery.
RPD                             Relative Percent Difference between two Duplicate pieces of analysis.
LCS                             Laboratory Control Sample - reported as percent recovery.
CRM                             Certified Reference Material - reported as percent recovery.
Method Blank                    In the case of solid samples these are performed on laboratory certified clean sands and in the case of water samples these are performed on de-ionised water.
Surr - Surrogate                The addition of a like compound to the analyte target and reported as percentage recovery.
Duplicate                       A second piece of analysis from the same sample and reported in the same units as the result to show comparison.
USEPA                           United States Environmental Protection Agency
APHA                            American Public Health Association
TCLP                            Toxicity Characteristic Leaching Procedure
COC                             Chain of Custody
SRA                             Sample Receipt Advice
QSM                             Quality Systems Manual ver 5.1 US Department of Defense
CP                              Client Parent - QC was performed on samples pertaining to this report
NCP                             Non-Client Parent - QC performed on samples not pertaining to this report, QC is representative of the sequence or batch that client samples were analysed within.
TEQ                             Toxic Equivalency Quotient


QC - Acceptance Criteria
RPD Duplicates: Global RPD Duplicates Acceptance Criteria is 30% however the following acceptance guidelines are equally applicable:
Results <10 times the LOR : No Limit
Results between 10-20 times the LOR : RPD must lie between 0-50%
Results >20 times the LOR : RPD must lie between 0-30%
Surrogate Recoveries: Recoveries must lie between 50-150%-Phenols & PFASs
PFAS field samples that contain surrogate recoveries in excess of the QC limit designated in QSM 5.1 where no positive PFAS results have been reported have been reviewed and no data was
affected.
WA DWER (n=10): PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFBS, PFHxS, PFOS, 6:2 FTSA, 8:2 FTSA


QC Data General Comments
1.    Where a result is reported as a less than (<), higher than the nominated LOR, this is due to either matrix interference, extract dilution required due to interferences or contaminant levels within
      the sample, high moisture content or insufficient sample provided.
2.    Duplicate data shown within this report that states the word "BATCH" is a Batch Duplicate from outside of your sample batch, but within the laboratory sample batch at a 1:10 ratio. The Parent
      and Duplicate data shown is not data from your samples.
3.    Organochlorine Pesticide analysis - where reporting LCS data, Toxaphene & Chlordane are not added to the LCS.
4.    Organochlorine Pesticide analysis - where reporting Spike data, Toxaphene is not added to the Spike.
5.    Total Recoverable Hydrocarbons - where reporting Spike & LCS data, a single spike of commercial Hydrocarbon products in the range of C12-C30 is added and it's Total Recovery is reported
      in the C10-C14 cell of the Report.
6.    pH and Free Chlorine analysed in the laboratory - Analysis on this test must begin within 30 minutes of sampling.Therefore laboratory analysis is unlikely to be completed within holding time.
      Analysis will begin as soon as possible after sample receipt.
7.    Recovery Data (Spikes & Surrogates) - where chromatographic interference does not allow the determination of Recovery the term "INT" appears against that analyte.
8.    Polychlorinated Biphenyls are spiked only using Aroclor 1260 in Matrix Spikes and LCS.
9.    For Matrix Spikes and LCS results a dash " -" in the report means that the specific analyte was not added to the QC sample.
10. Duplicate RPDs are calculated from raw analytical data thus it is possible to have two sets of data.


                                                                      Eurofins | mgt 1/21 Smallwood Place, Murarrie, QLD, Australia, 4172                                                Page 7 of 9
     Date Reported: Dec 06, 2018                                               ABN : 50 005 085 521 Telephone: +61 7 3902 4600                                            Report Number: 630200-S
Log in to download the original file

Appendix B - Geotech and Acid Sulfate report - MCU19-0030.pdf · 6.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.