200917 La Mer Working Drawings - Rev #

of 29

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                                                                                                                                                            Work in Progress
                                                                                                                                                                                     rev  date   issued details
                                 client sign-off:                   date:                                                                                                                                                                                                                                                Working Drawings
                                                                                                                                                                                     #-
                                                                                                                                                                                     WI 20.09.17 MS Working Drawings Rev#
                                                                                                                                                                                      P
                         1.           General Notes                                                         1.               General Notes                                              BAL-#                                                  BALUSTRADES                FLF-#                                                FLOOR FINISH

                         1.01          All shall be in accordance with the                                  1.11              All materials, adhesives, applied finishes and            BAL-01           Glass Balustrade                                                 FLF-01       Exterior Tiles
                                       accompanying drawings and to the                                                       other chemical based products such as paint
                                                                                                                                                                                                         Frameless glass balustrade panels. Rebated glazing                            Tiles over reinforced concrete slab in accordance
                                       satisfaction of the Architect.                                                         systems should be “0 VOC” unless otherwise                                                                                                               with Engineers Documentation. Tiles laid as per
                                                                                                                              approved by Architect.                                                     channel or grout fixed connections to be confirmed
                                                                                                                                                                                                                                                                                       manufacturers specification.
                         1.02          Figured dimensions take precedence over                                                                                                                           by glazing contractor. Allow for hydraulic patch
                                       scaled dimensions. Builder to verify on site                         1.12              All materials and products incorporated into                               fitted swing gates where indicated on drawings.                               Allow for fall to plumbed drainage points as
                                       prior to construction / fabrication.                                                   the works shall be fit for purpose and                                     Final set-out to be confirmed with architect                                  required. Refer to Hydraulic Engineer
                                                                                                                              installed in in accordance with manufacturers
                         1.03          All ground lines to be confirmed by Builder                                            instructions to comply with warranty                                                                                                                     Type: T-01
                                                                                                                                                                                                         Balustrade to finish 1000mm above finished floor
                                       prior to construction.                                                                 obligations. Copies of all relevant warranties                             level min. 1200mm where required for pool
                         1.04          Building set-out to be by licensed Surveyor,                                           shall be supplied to all contracting parties.                              compliance. Refer to Architects Drawings for                     HR-#                                                   HANDRAILS
                                       engaged by Builder.                                                  1.13              All timber, including bamboo, must be FSC
                                                                                                                                                                                                         finished heights.
                                                                                                                                                                                                                                                                          HR-01        Handrail

                         1.05          Refer any discrepancies to the Architect for                                           (Forest Stewardship Council) Certified or
                                                                                                                                                                                                         Glass type: Engineered high performance ionoplast                             Fabricated 32mm diameter min. 316 marine grade
                                       written instruction.                                                                   recycled. Rainforest timbers are not to be                                                                                                               stainless steel handrail, rolled returns and pin fixed
                                                                                                                                                                                                         toughened laminated glass (where required).
                                                                                                                              used. Copper Chrome Arsenic (CCA) treated                                                                                                                connections.
                                                                                                                                                                                                         Glazing contractor to confirm glass type. Ensure NO
                         1.06          All work and materials shall be in accordance                                          timber is not to be used. All timber shall be
                                                                                                                                                                                                         top handrail or channel is required.
                                       with the Building Code of Australia, the                                               kiln-dried or seasoned (certificates to be                                                                                                               Refer to stair detail drawings.
                                       relevant Australian Standards, the applicable                                          provided) unless prior approval of Architect is
                                                                                                                                                                                                                                                                                       Finish: Brushed
                                       codes and regulations of the destination                                               sought.
                                                                                                                                                                                                         Glass: Ultra clear low iron
                                       country and local council’s requirements. Any
                                                                                                            1.14              All elements specified to be painted or                                    Hardware: 316 Stainless Steel                                                 Shop drawings to be provided for approval.
                                       discrepancy or ambiguity shall be referred to
                                                                                                                              powdercoated are to be in accordance with                                  Finish: PT-03
                                       the Architect for written direction.                                                                                                                                                                                                            Must comply with NCC and AS1428.1-2009
                                                                                                                              Architect’s final colour scheme.                                           Supplier: Euroglass
                                                                                                                                                                                                                                                                                       requirements
                                       Specific attention is drawn to the following                                           Contractor to provide Architect 14 days
                                                                                                                              notice before the final selections are                                     Glass to comply with AS 1288 and relevant wind                   REN-#                                                     RENDER
                                       elements which must comply with the
                                                                                                                              required.                                                                  loadings.
                                       relevant Codes and Standards:                                                                                                                                                                                                      REN-01       Render finish 1
                                       - Termite treatment                                                                                                                              BAL-02           Glass Balustrade
                                       - Stormwater discharge                                                                 For site painting generally apply 2 finishing                              Patch fitted frameless glass balustrade panels.Allow
                                                                                                                                                                                                                                                                                       Rockcote Cerano Smooth Set cement render
                                                                                                                              coats over recommended undercoat                                                                                                                         System. Allow for acrylic based polymer to match
                                       - Watersaving plumbing fixtures                                                                                                                                   for circular dome head non climbable patch fittings.                          where required.
                                       - Smoke alarms                                                                         following appropriate priming of surface.                                  Allow for hydraulic patch fitted swing gates where
                                       - Energy efficiency requirements                                     1.15              All exposed fixings, plates, screws, nails and                             indicated on drawings. Final set-out to be confirmed                          Finish: Smooth Plastic Float - Lightly Burnished
                                       - Bushfire mitigation measures                                                         the like to be 316 grade stainless steel where                             with architect
                                                                                                                                                                                                                                                                                       Colour: Natural Cement
                                       - Insulation                                                                           appropriate or unless otherwise noted.
                                                                                                                                                                                                         Balustrade to finish 1000mm above finished floor
                         1.07          Any proposed changes to materials, finishes,                                           Structural connections shall be as Engineer’s                                                                                                            Allow for water and UV resistant clear matt
                                                                                                                                                                                                         level min. 1200mm where required for pool                                     penetrating sealer to manufacturers specifications.
                                       colours etc from those specified must be                                               Drawings. Use dome head or countersunk
                                                                                                                                                                                                         compliance. Refer to Architects Drawings for                                  Rockcote Repel.
                                       approved by the Architect PRIOR to                                                     fixings (as appropriate) wherever possible.
                                                                                                                                                                                                         finished heights.
                                       ordering.                                                                              Ensure separation of different metals via                                                                                                                3m2 sample to be provided for approval
                                                                                                                              rubber, neoprene gaskets, sleeves and/or
                                                                                                                                                                                                         Glass type: Engineered high performance ionoplast
                         1.08          The Client recognises that unauthorised                                                silicon joins.                                                                                                                              REN-02       Render finish 2
                                                                                                                                                                                                         toughened laminated glass (where required).
                                       changes to the project are not the
                                       responsibility of the Architect and releases                         1.16              Tile edges shall not be exposed. Coordinate                                Glazing contractor to confirm glass type. Ensure NO                           Render to match existing.
                                       the Architect from any liability arising from                                          with Architect to select proprietary or                                    top handrail or channel is required.

                                       the construction, use or result of such                                                standard edge trims.                                                                                                                                     Finish: Scratch coat render
                                                                                                                                                                                                         Glass: Ultra clear low iron
                                       changes.                                                             1.17              Upon completion, the site is to be                                                                                                                       Colour: To match existing
                                                                                                                                                                                                         Hardware: 316 Stainless Steel
                         1.09          All work referred to in this schedule is by                                            professionally cleaned for handover.                                       Finish: PT-03
                                       Builder, unless noted otherwise. Work noted                          1.18              Completion testing: All plant and equipment                                Supplier: Euroglass
                                       by “Joiner” or other specialist contractor is                                          is to be tested, commissioned, and adjusted
                                       to be attended upon by the Builder.                                                    as required to be in proper running order.                                 Glass to comply with AS 1288 and relevant wind
                                                                                                                                                                                                         loadings.
                         1.10          No material, finish or item used in the project                      1.19              Vermin treatment: provide certificates for all
                                       may include any asbestos or hazardous or                                               pest and vermin treatments.
                                       toxic substances or materials.




                       Sparks Architects Pty Ltd 20200507
                                                                                       a: shop 5, 212 david low way, peregian beach, qld 4573
                                                                                       p: (07) 5471 3033                                        Alterations and Additions   2 of 7      Sparks Architects Pty Ltd                                               Scale                                                                     5 of 7
                          sparks architects                                            www.sparksarchitects.com
                                                                                                                                                37 Hastings Street, Noosa Heads                 La Mer Body Corporate                    141       MS           Materials + Finishes Schedule                        WD 1.2
                                                                                       sparks architects pty. ltd. abn 89 124 611 721
                                                                                       qld architect's registration No. 3974                    project                                         client                                   job no.   drawn        drawing                                              dwg no.
GSPublisherVersion 166.6.74.18
Log in to download the original file

200917 La Mer Working Drawings - Rev #.pdf · 5.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.