Council archive · source document
Part 8 of 37 Appendix 6 - Flood Study MCU12/0208
Very large file (93.6 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Sunshine Coast I InndHE.OY I
Regional Council
are you? www.floodready.goY.au
Drainage Deficient Areas
Council advises that the land is in a declared drainage deficient area as shown on Regulatory Map1.5: Flood Prone
D and Drainage Constraints Area in Maroochy Plan 2000 R2.
Council advises that the land is not in a declared drainage deficient area as shown on Regulatory Map1.5: Flood
EJ Prone and Drainage Constraints Area in Maroochy Plan 2000 R2.
Flood Regulation Lines (for Petrie Creek only)
D Council advises that the land is subject to the provisions of Flood Regulation Lines.
Council advises that the land is not subject to the provisions of Flood Regulation Lines.
EJ
CLIMATE CHANGE
The advice provided in this certificate is based upon standards relating to current climatic conditions and historically recorded
flood events only. Please be aware, the current standards do not include allowances for future climate change projections in
our region. These projections include but are not limited to; increased rainfall intensity, higher mean sea level and more
extreme weather conditions (e.g. storm surge and tropical cyclones).
NOTES FOR FLOOD INFORMATION
1. The absence of Highest Historical Flood Level information does not imply that the above property is not subject to
flooding, simply that Council has no record of this property flooding. Applicants are encouraged to make their own local
enquiries.
2. The MINIMUM FLOOR LEVEL is calculated as whichever is greater of either:
(a) 500mm freeboard added to the Defined Flood Level for the site; or
(b) 800mm freeboard added to the Defined Flood Level for the site if the property is located in the Noosa River
catchment only in accordance with the Noosa River Flood Study;
(c) 500mm freeboard added to the Highest Historical Flood Level appropriate to the site; or
(d) If the property is intended for use as a Hospital or Emergency Services Facility then the Sunshine Coast Regional
Council should be contacted to determine this level.
3. Council advises that if stormwater drainage pipelines/easements exist on the property then no earthworks or building are
permitted in the easement.
4. All buildings shall conform to the relevant Planning Scheme Code in the Maroochy Plan 2000 R2.
5. Please be aware of the natural topography in your area. Water runoff which exceeds the capacity of the underground
drainage system (if present) and which concentrates in surface depressions and gullies as it flows down a catchment can
cause localised flooding and is not identified in this certificate.
6. Filling must not cause actionable nuisance in accordance with Queensland Urban Drainage Manual.
T 07 54758501 F 07 54418338 [email protected]
PO Box 76. Nambour QLD 4560 www.sunshinecoast.qld.gov.au
Flood Search Certificate (FSCV3-0809) Page 2 of 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 8 of 37 Appendix 6 - Flood Study MCU12/0208Related documentApplication case desk ↗