Council archive · source document
Second Report · 131999.982632.1
Town Planning Department’s Reports 16/7/1999 - Ordinary Meeting 29/7/1999 18 With regard to the stairwell to the roof top terrace, the applicant has presented an option of circular external stairs which would fully comply with section 5.3.1.5 of the Planning Scheme being the relevant clause for roof top terraces on duplexes. However he is seeking Council’s reconsideration of this matter and in particular a modification to this section of the Planning Scheme in accordance with the modification provisions of section 5.3.2. The applicant believes the external circular stair compromises the integrity of the design and is more visually prominent. He also believes these circular stairs present a safety concern for elderly residents. The applicant took issue with suggestions within the Planning Report that the proposed stairs would eventually become fully enclosed to weather proof the stairwell adding both bulk and height to the building. The applicant says this is not the intention and there are design measures to ensure these internal stairs remained drained. However as a means of demonstrating that there is no intention to fully enclose the stairs, he has modified the plan of the stairwell by turning the stair 90 degrees and enclosing the lower flight of the stair to the roof top with an angled roof and glazed walls and surrounding the entire flight with open external louvres. This ensures safe drainage of the top most flight with the landing open on two sides and the two flights open on one. The waterproofing technique for the slab is no different for the flight than for the trafficable roof top. The applicant suggests this solution is far less visually intrusive to neighbours and it addresses Council’s concerns about exposing the stairwell to the elements of nature. It also does so without adding height or bulk to the building. Conclusion The applicant has presented one option for a roof top terrace which meets the requirements of section 5.3.1.5 of the Scheme, however seeks modification to allow for a more preferred option. His preferred roof top terrace would not appear to have any adverse impact on the amenity of the neighbourhood. It will be relatively unobtrusive and while the stairs are semi enclosed these enclosures do not exceed the 8 metre height limit. This representation is supported and a negotiated decision notice, with an amendments to the: conditions is recommended. SMP c:\prod\word\doc\finalrep\99-07-16-ppa.doc 16/07/99
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Second Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.