Noosa Plan 2006 Planning Scheme Code Assessment


                                                              Table 14-27 For Multiple housing Type 5 – Relocatable
 Performance Outcomes                                         Acceptable Outcomes                                          Comment
 O52 Visitor parking spaces are located conveniently to all                                                                Complies. The proposed development layout has
 dwelling units.                                                                                                           appropriately dispersed visitor car parking throughout the
                                                                                                                           site.


Part 14 – Division 3 – Business Uses Code
                                                                         Table 14-8 For all Business Uses
 Performance Outcomes                                         Acceptable Outcomes                                          Comment
 14.16 Effects of use
 Electricity supply infrastructure
 O18 The development does not adversely impact on             S18.1 No solution provided                                   Complies. The proposed development will not adversely
 existing or future electricity supply infrastructure;        S19.1 Development for uses adjacent to or within 50m of      impact on existing or future electricity supply
 AND                                                          an existing electricity substation incorporates noise        infrastructure.
 O19 All uses and works maintain an adequate safe             attenuation measures to mitigate noise impacts;
 distance from electrical infrastructure including            AND                                                          Not applicable. The subject site is not located within
 substations, overhead powerlines, power poles and            S19.2 Buildings and structures (including swimming pools,    proximity to an existing electricity substation.
 transformers                                                 sheds, tennis courts and outbuildings) are not constructed
                                                              under overhead electricity transmission lines, or within     Complies. The proposed development is not located under
                                                              electricity easements.                                       overhead electricity transmission lines, or within
                                                                                                                           electricity easements.
 Noise
 O20 Development is designed and sited to avoid noise         No solution provided                                         Complies. As detailed in the Acoustic Assessment Report
 emissions that unreasonably diminish the amenity of the                                                                   at Attachment 7, the proposed development will not
 area or surrounding uses.
                                                                                                                           generate any reverse amenity impacts on surrounding
                                                                                                                           development.
 Mechanical plant and equipment and storage areas
 O21 Mechanical plant and equipment (including air            S21.1 Mechanical plant and equipment are—                    Complies. Mechanical plant and equipment will be
 conditioning equipment) and storage areas are designed       a) located more than 2m from any property boundary;          appropriately located and screened to not impact upon
 and located to—                                              b) where located at ground level, screened by fencing        visual amenity.
 a) avoid adverse visual impacts when viewed from the         1.5m in height or dense vegetation of at least 1.5m in
 street and adjoining properties; and                         width incorporating grouped trees and shrubs with
 b) visually integrate with the building design


                                                                                     Page 20 of 26
Log in to download the original file

Attachment 13 - Code Assessment.pdf · 760 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.