Original source · versioned page text
Attachment 13 - Code Assessment
Noosa Plan 2006 Planning Scheme Code Assessment
Table 14-8 For all Business Uses
Performance Outcomes Acceptable Outcomes Comment
O29 Public toilets are designed and constructed to— a) AND
ensure the safety of all people using them; and S24.4 Recessed doorways are avoided where the recess is Complies. The golf club house has been designed to
b) take advantage of informal surveillance from adjoining of sufficient size to conceal a person. Where recessed reduced recessed areas of the external façade.
uses and activities, discouraging non-legitimate uses. doorways are unavoidable, measures are used to enhance
safety, as follows—
a) good lighting installed;
b) strategically placed mirrors installed;
c) angled approaches provided; or
d) gates which restrict access provided.
S25.1 Windows and main entrances are positioned to Complies. The building incorporates windows and doors to
allow for casual surveillance. provide casual surveillance.
S26.1 Communal open spaces, including congregation and Complies. The outdoor seating areas are highly visible
seating areas are situated where they are in the line of from the internal restaurant, café and function room
sight of windows, doors and/or balconies of buildings, or areas.
can be seen from a street or other public space.
S27.1 Buildings or structures that are visible from a public Not applicable. The building is not visible from a public
street or laneway— street/laneway.
a) avoid the use of solid fences and blank walls which
attract graffiti. Where solid blank surfaces are
unavoidable, measures in the form of landscaping,
creepers, murals, vandal resistant paint, etc are used;
b) use toughened glass, security screens and other
measures (but not including security shutters that obscure
the view of shopfronts) are used in windows which are
provided at ground level, to deter break and enters; and
c) use hardy vandal proof materials and antigraffiti paint
are used in the construction of buildings.
S28.1 Lighting of appropriate intensities is provided which Complies. The golf clubhouse will be appropriately lit to
satisfies the requirements of Australian Standard AS1158: comply with the requirements of Australian Standard
Public Lighting Code, unless otherwise specified in this AS1158: Public Lighting Code.
Code;
AND
S28.2 External lighting of a graduated intensity is provided Complies.
which starts at a lower level of brightness at the perimeter
Page 22 of 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.