Altum Constructions Noise Management Plan Prepared For Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads Page 10 of 12 General The following additional noise control measures have been incorporated into the Facilities Building: 1. Approximately 75% of the outdoor dining area is roofed over; 2. For that part of the roof closest to the café (roof with ceiling lining below), approximately 75 m 2 has acoustic absorbent panelling incorporated into the ceiling lining. This represents approximately 50% of the primary roofed area out from the café (but not including the additional awning which is roof only – no ceiling lining). 3. Trading hours for the café and outdoor dining areas is limited to 0600 hours to midnight daily. 4. In accordance with Noosa Council Condition 85, once the Facilities Building is completed final certification is required from an appropriately qualified acoustic consultant confirming that all of the noise control requirements of the approval have been complied with. The following additional noise control measures have been incorporated into all of the residential apartments: 1. ALL residential apartments are fully air-conditioned (all habitable rooms); 2. Residential apartment glazing facing the Facilities Building (for the closest Blocks, namely 2, 3 and 4, as well as 18 to 21) is 6 mm thick toughened glass for sliding glass doors and, for any windows above the sliding glass doors, 6 mm float glass, both of which are thicker (and provide greater noise reduction) than what would normally have been installed when the original 2006 noise report was prepared. 3. Every residential apartment balcony has full height (and full depth of the balcony) end walls (masonry construction) which are, effectively, wing walls for those apartments not directly in line with the Facilities Building and in particular the outdoor dining area. 4. Solid balustrading at least 1000 mm high to all residential balconies, with this solid balustrading acting as an acoustic barrier. Complaint Response In the event of a complaint about noise being received, the person taking the call will record as much information as possible, including: complainant’s full name; complainant’s address; complainant’s contact telephone number (mobile or land line); nature of their complaint, for example, time that the noise was audible, location where the noise was audible (inside or outside residence), type of noise – continuous or stop/start or varying over time, likely source of noise such as air-conditioning units, pump, etc. Refer Attachment A for a copy of a Complaint Response Form. After obtaining the above detail (or as much detail as the complainant is willing to provide) the person taking the complaint to advise the complainant that there is a Noise Management Plan in place for the Facilities Building and that this requires that both the Facilities Building Manager as well as the Body Corporate Manager will be involved in the investigation of their complaint. The complainant should also be advised that if it is found that there has been non-compliance with this Noise Management Plan that action will be taken to ensure that the breach does not occur again. David Moore & Associates Pty Ltd Our reference: R19084/D3295/Rev.3/19.12.19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noise Management Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.