Altum Constructions Noise Management Plan Prepared For Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads Page 8 of 12 o Block 18, 19, 20 and 21, west facing balconies Whenever possible diners should be located as close as possible to the café/shared space, to minimise their line of sight to the closest residential. Compliance with the above will also result in noise limit compliance with all ‘off-site’ residential. It should also be noted that if the café and outdoor dining area are to have a Liquor Licence then patron noise limits and noise control is a matter for the Office of Liquor and Gaming Regulation. Amplified Music On the basis that the café and outdoor dining area will have a Liquor Licence, then the noise limits for amplified entertainment (and patron noise) will be detailed on their Liquor Licence. To establish amplified music noise limits the Office of Liquor and Gaming Regulation will require an actual amplified music noise assessment to be conducted. This will need to include background noise assessments at 2200 hours and midnight, to define the residential noise limits, as well as an assessment of actual amplified music conducted concurrently from 3 metres from the speakers and at the closest residential. As a preliminary indication of the permissible volume which achieves compliance with the time varying noise limits, the amplified music noise limits for the in-house speaker system are: daytime and evening (0700 to 2200 hours): 80 dB(A) LAeq,adj,T at 3 m from the speakers; night-time (0600 to 0700 and 2200 hours to midnight): 76 dB(A) LAeq,adj,T at 3 metres from the speakers. For the above amplified music noise limits the noise control measures are as follows: all speakers located just below ceiling height; all speakers directed downwards; all speakers located within the area defined in Figure 3; no speakers in addition to the in-house speakers are permitted on site; any live performer must play through the in-house system. David Moore & Associates Pty Ltd Our reference: R19084/D3295/Rev.3/19.12.19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noise Management Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.