Council archive · source document
Geo-environmental Investigation · MCU25/0020
Very large file (12.4 MB): the original may take a few minutes to open or download. The page text below is quick to read.
1. Introduction This report details the results of a geotechnical and acid sulfate soils (ASS) investigation undertaken for a proposed residence at 11 Ravenwood Drive, Noosa Heads. The investigation was performed by Tectonic for Sunshine Beach Noosa Developments Pty Ltd, generally in accordance with Proposal P25064-Rev0 dated 7 February 2025. The investigation comprised a site walkover and drilling of boreholes at two locations, in situ soil strength testing and environmental laboratory testing. This report summarises the results of the investigation and provides geotechnical recommendations regarding earthworks, footings, temporary and permanent retention and groundwater management, together with an assessment of the extent and severity of ASS. 2. Proposed Development Architectural drawings supplied to Tectonic (Ref. Chris Clout Design [CCD], Project Name. River Oasis, Sheet Nos. C0.0 to C5.3 [16 sheets], Issue Preliminary Concept, dated 14 February 2025) indicate that the proposed new residence will comprise a two-storey building over a single level basement. Construction will likely comprise rendered masonry, with suspended concrete upper floors and roof. An arc shaped pool will be positioned adjacent to the lower floor level in the north-eastern corner of the site, being setback about 2 m from the existing canal revetment wall. Concrete steps are also proposed off the eastern edge of the house down to the revetment wall. Plans suggest that a jetty is also proposed as part of the works. Civil drawings prepared by SCG Consulting Engineers (SCG, Ref. Drawing Nos. 0280, Various Sheets, dated February 2025) indicate that excavations for the basement level will generally range between about 3 m and 4 m deep, however, isolated deeper excavations ranging up to about 4.5 m deep are expected for a car lift pit. Excavations for the pool are indicated to range up to about 1.5 m deep, with no filling proposed across the site. It is understood that contiguous piles are proposed around the full perimeter of the basement. Preliminary information provided by SCG indicates that serviceability loads beneath the basement floor slab would be in the order of about 30 kPa to 40 kPa, with isolated column loads at basement level in the order of about 1500 kN and line loads under the basement walls being around 200 kN/m. Text Figure 1 overleaf provides a layout plan and cross-sectional views of the proposed development. Geo-environmental Investigation Proposed Residence 11 March 2025 | 25040-001-Rev0 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Geo-environmental Investigation.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.