Original source · versioned page text
Amended Planning Report
Water conservation and storage Condition of building
O20 On-site water storage is S20.1 If not in a water service area approval. Can be
provided, designed and operated to each Detached house is to be conditioned to comply.
support the efficient use of water serviced with a rainwater tank of the
and is adequate for occupants every following minimum storage capacity:-
day use. a) For Detached houses with no
more than 3 bedrooms –
45,000 litres; or
b) For Detached houses of
more than 3 bedrooms or
AND
where including a 2nd
dwelling unit on the same
premises – 60,000 litres;
AND
O21 Detached houses and S21.1 If not in a reticulated water
Ancillary dwelling units service area— there is, on the lot, a
within Bushfire Hazard Areas21 have dam, swimming pool or water tank
sufficient water supply for fire fighting accessible for use by the fire brigade,
purposes. that contains at least 5,000 litres of
water.
Effluent Disposal Plumbing approval and
O22 Effluent disposal does not have No solution provided (no requirement effluent disposal report
a significant adverse effect on for accepted development attached to this report.
biodiversity, natural vegetation or development)
water quality22. The surface irrigation
area is located outside
O23 Treatment and disposal of of the riparian buffer
wastewater does not have any overlay.
detrimental impact on Noosa’s major
water storage and supply - Lake The proposed detached
Macdonald. house use is consistent
with the surrounding
area and will not
adversely impact
existing conditions.
Environmental Protection Complies – Existing
O24 The design, siting and S24.1 Where there is an existing clearing. No removal of
construction of buildings and building envelope on the lot that native vegetation
structures minimise the clearing of contains vegetation protection required.
vegetation and where there is an measures, clearing of native
existing preliminary approval that vegetation and building works do not
includes vegetation protection extend beyond the building envelope,
measures for the property, the except for the purposes of a driveway
proposal is consistent with those access;
measures.
AND
S24.2 Where there is no building
envelope existing on the lot, clearing
of native vegetation, other than for a
driveway access does not extend
beyond—
a) 30m of a building or 10m of a
structure on lots greater than
10ha; or
b) 10m of a building or structure on
16 | P a g e
See the original
The page text is free to read. Viewing or downloading an original file needs an account.