Original source · versioned page text
6.5.22 - 60 Glenridge Drive Cooroibah Effluent Disposal Report-B
User’s Guide – Advanced E n v i r o - S e p tic Sy s te m
Table 4 - Enviro-Septic System Components
Component of the Function Follow-up Frequency Responsible for
septic system needed follow-up
Septic tank Primary wastewater Periodic emptying According to Owner is res-
Treatment standards and ponsible to have
regulations in work done by
effect qualified person
Septic Tank Effluent Retention of solids in According to manufacturer’s instructions.
Filter4 low pressure pumped
applications.
Distribution systems if
required for larger dual
bed systems
3 options
A) Gravity Dist A) According to A) As needed A) Owner
box and flow water level in the
equalizers Distributes the septic inspection port
tank effluent to the rows
B) Pressure of Advanced Enviro- B) According to the manufacturer’s directions.
distribution Septic.
(feed) system
C) Automatic C) According to the manufacturer’s directions.
distributing
valve
Rows of Advanced Distribute and treat
Enviro-Septic Pipes. Wastewater
Sampling device To verify the treatment Ensure that there Optional Qualified person
performance of the is access to this
Enviro-Septic System device
Vent To allow the circulation Ensure that the As needed Owner
of air in the Enviro- opening is not
Septic System blocked
System sand To complete the water No
treatment process and to
improve the drainage
Pumping station Lift septic tank effluent According to supplier’s specifications
(optional) to the Enviro-Septic
System
4
The effluent filter is necessary whenever the septic tank is followed by a low pressure distribution system.