6.5.22 - 60 Glenridge Drive Cooroibah Effluent Disposal Report-B
EFFLUENT LOADING RATE
4.1 Introduction
For this report we will use a of a four-bedroom house, each dwelling will
discharge to a 4000 litre all purpose septic tank and discharge to 90m² of and
Advanced Enviro-septic disposal area.
ON-SITE DISPOSAL SYSTEM
5.1 Introduction
The on-site sewerage treatment for this site will need to be an Secondary
Treatment Quality.
5.2 Effluent Treatment & Disposal
Using the 4-bedroom model for 6 persons at 150 litre per day will deliver 900
litres per day. This amount of effluent is to discharge to 90m² of effluent disposal
area if the land application area. The new effluent disposal area will be a AES Bed.
This bed will be within the building envelop. with the compliant set back distances
from AS 1547-2012 and stated in section 3 of this report.
Attached in this report is a demonstration of the purpose method and location of
the disposal area.
The AES effluent disposal system can produce Advance Secondary Quality Effluent
with a 10m set back distance from any water course.