Council archive · source document
Revised Proposal Plans · MCU13/0261
Attached to the e-mail MCU13/0261 - Response to Information Request - 5 Stevens Street Sunshine Beach.
Plans and drawings: the text below has words only, no drawings.
Original PDF page 12, section 1. The text section number identifies this passage in the reader.
EXTERNAL FINISHES LEGEND
(refer to A4 schedules for material description)
AS aluminium screen.
AFL aluminium framed louvres, refer sched.
AFL aluminium framed window, refer sched.
AL aluminium louvres, refer sched.
designers
AFS aluminium framed slider, refer sched.
8.0m max
imum buil
TV MR AFD aluminium framed door, refer sched. PO Box 262
Noosa Heads QLD 4567
ding heig TV MR
ht TV MR BA sun control battens, refer detail. Telephone 07 5447 5633
MR BL1 balustrade type 1, refer [email protected]
BL2 balustrade type 1, refer detail.
www.kiddco.com.au
MA BLK masonry blockwork.
BED 1 This drawing is to be read in
DINING MA
CL ceiling lining. conjunction with Engineers Drawings &
AFL AFL Reports
AFW AFS
W34 BED 1
DINING
CS concrete slab.
Hardies 150 linea clad, W32 AFL AFL Construction to comply
FC sheet with cover battens over
W66 AFL AFL AFS FC DP down pipe. with all relevant SAA &
37,100 First Floor W37 W36 W68 FC fibre cement external cladding. BCA Codes & standard
Bldg By-law 1975 & as
MA
W64 W62 W61 WB
36,350 First Floor FG fascia gutter. amended
Verify all dimensions on
BED 2 RHB rendered hebel block site prior to commencement
LAUNDRY ENTRY
3,200
AFL MA MA metal awning, refer detail. of any works. These
BED 2 ENTRY drawings are not to be
LAUNDRY MAK polycarbonate roof sheeting, refer schedule.
3,200
W01 AFL used for scaling
AFL MR metal roofing. Copyright for design &
D08 W31 drawings remain the
33,900 Ground Floor
rendered block veneer NGL natural ground line. property of the authors.
natural ground
line W29 33,150 Ground Floor PW parapet wall. CONSULTANTS
PAB powder coated alum. battens Structural Engineers
SCG Consulting Engineers
3,200
GARAGE RC ridge capping. Contact: Sean Richardson
GARAGE STORE Phone: (07) 5455 5604
2,850
SK skylight refer detail & schedule.
Surveyor
SP structural post, refer engineer. Max Watterson & Associates
30,700 Garage Level D03 D04 Contact: Max Watterson
D07 D06
SL soffit lining Phone: (07) 5442 6121
30,300 Garage Level
SF structural footing, refer engineer. Private Certifier
UNIT 1 STR stair, refer engineer. Suncoast Building Approvals
Phone: (07) 5443 7288
TER tapered exp. rafters Hydraulic Engineer
TV turbo vent. SCG Consulting Engineers
Contact: Sean Richardson
WB weatherboard cladding
SECTION E
Phone: (07) 5455 5604
Landscape Architect
WD.603 SCALE1:100 Seed Landscape Architects
Phone: (07) 3217 6491
1-1 1-2 1-3 1-4 1-5 1-6 1-7
1,200 5,600 4,600 3,000 2,420 4,400
TV MR
8.0m maximum
building heig
ht
silicon joint corner window
silicon joint corner window
FC
FC
MA
MA ENS BED 1
horticultural structure DECK
3,280
W47
BL1
banquette W68
raking timber post raking timber post
36,350 First Floor
FC
fence LANDSCAPE
TERRACE ENS BED 1
MA
TERRACE rendered block privacy wall
W16
3,200
frameless glass pool fence
banquette W31
wc
Issue for Information 22/01/14
33,150 Ground Floor
G01
Project
PROPOSED DUPLEX
2,450
GARAGE
G02
Location
D01
30,700 Garage Level
driveway to engineers detail 5 STEVENS STREET
SUNSHINE BEACH
880
29,820 Kerb Level retaining wall to retaining wall to engineers detail
Kerb 29,820 Client
engineers detail
UNIT 1 PILCHER + STAY
Drawing Title
SECTIONS
SECTION F Scale
as shown @A2 NOV 13
Date
WD.603 SCALE1:100 Drawn By Job No:
DDT 1306
Drawing No. Issue No.
WD.603 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Proposal Plans.PDFRelated documentApplication case desk ↗
About this file
- File size
- 3.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.