1-1 1-2 1-3 1-4 1-5 1-6 1-7
1,200 5,600 4,600 3,000 2,420 4,400 designers
100 1,100 100 10,900 100 3,000
600 PO Box 262
100 2,200 100 2,500 100 1,900 100 100 3,900 100 Noosa Heads QLD 4567
Telephone 07 5447 5633
E NE
#LayID [email protected]
www.kiddco.com.au
MA MA MA MA
This drawing is to be read in
horticultural structure at 900 centres to conjunction with Engineers Drawings &
line of roof over Reports
polycarbonate if necessary,
refer engineer RP
W42 W41 W40 W39 W38 2.0m setback
1-A B B Construction to comply
line of roof over
800
100
100
100
#LayID #LayID
W37
s ref line of pool below with all relevant SAA &
BCA Codes & standard
UNIT 1 Bldg By-law 1975 & as
W43
amended
line of roof over
KITCHEN DINING LIVING
3,300
Verify all dimensions on
4,200
FFL 37,100 FFL 37,100 FFL 37,100
4,400
site prior to commencement
4,200
timber timber timber of any works. These
W36
DECK drawings are not to be
line of roof over
used for scaling
100
W44
FFL 37,100
5,600
timber Copyright for design &
pantry 12.13.14.15.16.17.
drawings remain the
800
up
100
property of the authors.
1-B W35 line of pool below CONSULTANTS
600
100
100
A A
wc D24
WD.601 WD.601 Structural Engineers
fall 5°
line of roof over
line of roof over
BBQ
MR RP
SCG Consulting Engineers
1,975
1,300
Contact: Sean Richardson
W34
D25
W33 Phone: (07) 5455 5604
W45 BED 1
4,100
3,975
FFL 37,100 line of Surveyor
100
E/S
line of roof over
100
carpet walls Max Watterson & Associates
FG below
banquette
tile Contact: Max Watterson
W32
W46
1,975
Phone: (07) 5442 6121
1,900
screen
6.0m setback
shr Private Certifier
60/60/60 twin stud wall, Suncoast Building Approvals
1-C F CSR System 103 F Phone: (07) 5443 7288
250
100 1,900 250
250
#LayID #LayID Hydraulic Engineer
line of roof over
F1 to
horticultural structure at 900 centres shr
banquette
ck
#LayID screen SCG Consulting Engineers
polycarbonate if necessary,
setba
W47
W68
Contact: Sean Richardson
1,975
line of roof over
WE refer engineer E/S Phone: (07) 5455 5604
3,200
D27
6.0m
tile BED 1
3,375
EE Landscape Architect
100
2-A W48
FFL 36,350 FG
Seed Landscape Architects
carpet W67
W66
100
Phone: (07) 3217 6491
975
800
2-B wc
1-D
400
D capping and flashing
#LayID to match roof sheeting,
100
100
MR
W49
fall 5°
void D26
2,580
W50 refer to External Finishes Schedule
up line of
W65
walls
ver
W51
9. 10 below
roof o
.11.12
.13.14
.15.16
W64
100
.17.18
2-C .
BBQ
C
line of
WD.602 KITCHEN W63 line of
roof o
UNIT 2
1,020
FFL 36,350 ver
W52
timber
2-D RP
DINING
W62
W53
100
FFL 36,350
timber
ver
s LIVING DECK line of
roof o
pool b
100
ref FFL 36,350 timber elow
W61
5,600
W54 timber
line of
W55
W60
MA W56
line of
4,500
roof o
ver W57 RP
W59
MA
W58 D
#LayID
2.0m
900
MA setba line of
E ck pool b
elow
100 500 #LayID
100
100 SE
3,200 C
600 WD.602
100
3,100
2-1 Issue for Information 22/01/14
2-2
3,700
8,100
Project
2-3
PROPOSED DUPLEX
3,900 100
2-4 3,900
Location
3,000 5 STEVENS STREET
2-5 SUNSHINE BEACH
2,101
Client
2-6
4,400 PILCHER + STAY
2-7 Drawing Title
FIRST FLOOR PLAN
2-8
Scale Date
as shown @A2 NOV 13
Drawn By Job No:
DDT 1306
FIRST FLOOR PLAN Drawing No. Issue No.
WD.203 SCALE1:100 WD.203 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Proposal Plans.PDFRelated documentApplication case desk ↗
About this file
- File size
- 3.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.