Approved Plans - 132002.220261.1 (As Published)

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
    GENERAL                                                                                           DIMENSIONS/LEVELS                                                                                              TIMBER FRAMING & BRACING:                                                                                ABBREVIATIONS:
    G1    STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE                                   L1.    CONSTRUCTION SHALL BE SET OUT USING SURVEY BENCHMARKS PROVIDED BY COUNCIL.                              T1      ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 1720, AS 1684                       A.C.F. -     ALL CORES FILLED
          SPECIFICATION, ARCHITECTURAL, AND OTHER CONSULTANTS' DOCUMENTS.                                                                                                                                                    AND THE REFERENCED STANDARDS THEREIN.                                                            BTM.     -   BOTTOM
                                                                                                      L2.    ALL LEVELS AND SETOUT POINTS ARE SHALL BE CONFIRMED ON SITE BY REGISTERED                                                                                                                                        B.W.     -   BOTH WAYS
    G2    REFER TO THE ARCHITECTURAL DRAWINGS FOR SETOUT. NO DIMENSIONS SHALL BE                             SURVEYOR PRIOR TO CONSTRUCTION. ADVISE ANY DISCREPANCY BEFORE PROCEEDING.                               T2      ALL FRAMING, BRACING AND TIE-DOWN INFORMATION FORMS THE BASIS OF THE                             CB       -   CONSTRUCTION BREAK
          OBTAINED BY SCALING FROM DRAWINGS.                                                                                                                                                                                 STRUCTURES STABILITY DOWN TO FOUNDATIONS. ALTERNATIVE METHODS SHALL                              C.O.S. -     CONFIRM ON SITE
                                                                                                      L3.     DIMENSION STANDARDS:                                                                                           ONLY BE ACCEPTED ON APPROVAL OF THE ENGINEER.                                                    D&C      -   DESIGN & CONSTRUCT
    G3    UNLESS OTHERWISE NOTED (UNO), ALL LEVELS ARE IN METRES AND ALL DIMENSIONS ARE IN                   - REDUCED LEVELS, CHAINAGES AND COORDINATES ARE ALL IN METRES.
                                                                                                                                                                                                                                                                                                                              DWG      -   DRAWING
          MILLIMETRES.                                                                                       - CIVIL DRAWINGS (SKC SERIES): ALL OTHER DIMENSIONS ARE IN METRES (m).                                  T3      PREFABRICATED TIMBER ROOF TRUSSES, PROPRIETARY FLOOR JOIST SYSTEMS
                                                                                                                                                                                                                                                                                                                              E.F.     -   EACH FACE
                                                                                                             - STRUCTURAL DRAWINGS (SKS SERIES): ALL OTHER DIMENSIONS ARE IN MILLIMETRES (mm).                               AND ALTERNATIVE TIMBER ELEMENTS TO THOSE SHOWN ON THE ENGINEERING
                                                                                                                                                                                                                                                                                                                              H.D.G. -     HOT DIP GALVANISED
    G4     THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STABILITY OF THE                                                                                                                                          DRAWINGS ARE TO BE DESIGNED AND CERTIFIED BY THE SUPPLIER'S STRUCTURAL
          STRUCTURE UNTIL ITS COMPLETION AND SHALL ENSURE THAT NO PART OF THE STRUCTURE               L4.    ALL LEVELS ARE TO AUSTRALIAN HEIGHT DATUM.                                                                      ENGINEER. DESIGN AND INSPECTION CERTIFICATES FOR THESE ELEMENTS ARE TO BE                        Lg.      -   LONG
          IS OVER-STRESSED BY EXCESSIVE LOADING.                                                                                                                                                                             ISSUED TO THE CONTRACTOR FOR LODGEMENT WITH THE LOCAL AUTHORITY.                                 L.V.     -   LENGTH VARIES
                                                                                                      L5.    DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS.                                                                                                                                                                    N.S.O.P. -   NOT SHOWN ON PLAN
    G5    ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE CURRENT VERSION                                                                                                                              T4      ALL TIMBER MEMBERS USED ARE TO HAVE A MINIMUM LEVEL OF DURABILITY AS                             SS       -   STAINLESS STEEL
          OF THE APPLICABLE STANDARD EXCEPT WHERE VARIED BY THE SPECIFICATION AND/OR                  L6.    DESIGN USES DIGITAL TERRAIN MODEL GENERATED FROM THE SITE SURVEY. SOME                                          SPECIFIED IN AS1684.2 - APPENDIX B.                                                              TYP.     -   TYPICAL
          DRAWINGS. APPLICABLE CODES OF PRACTICE INCLUDE BUT ARE NOT LIMITED TO THE                          ELEMENTS ARE INTERPOLATED AND MAY VARY FROM THE ACTUAL SITE CONDITIONS                                                                                                                                           U.N.O. -     UNLESS NOTED OTHERWISE
          FOLLOWING:                                                                                                                                                                                                 T5      ALL HWD TIMBER SHALL BE SEASONED UNO.                                                            V        -   VARIES
          AS 1163        STRUCTURAL STEEL HOLLOW SECTIONS
          AS 1170        SAA LOADING CODE                                                                                                                                                                            T6      ALL TIMBER SHALL BE FREE OF GUM VEINS, KNOTS, SHAKES, CHECKS, WANES AND ANY
          AS 1554        WELDING OF STEEL STRUCTURES                                                  CONSTRUCTABILITY CONSTRAINTS:                                                                                          OTHER IMPERFECTIONS WITHIN CONNECTION ZONES.
          AS 1664        ALUMINIUM STRUCTURES
          AS 1684        RESIDENTIAL TIMBER-FRAMED CONSTRUCTION                                       CC1. CONSTRUCTABILITY CONSTRAINTS:                                                                             T7      ALL TIMBER FRAMING TO BE MINIMUM H5 TREATED UNO.
          AS 1720        TIMBER STRUCTURES
          AS 2159        PILING CODE                                                                    A)   PROTECT ALL EXISTING INFRASTRUCTURE (EG REVETMENT WALLS, PAVEMENTS,                                     T8      EXPOSED FRAMING (TIMBER FRAMING THAT MAY BE SUBJECT TO PERIODIC WETTING):
          AS 4100        STEEL STRUCTURES                                                                    FENCING & ELECTRICAL POLES/WIRES) FROM ANY DAMAGE.                                                                  - SHALL BE EITHER H6 PRESSURE TREATED OR DURABILITY CLASS 1
          AS 4997        GUIDELINES FOR THE DESIGN OF MARITIME STRUCTURES                                                                                                                                                          SPECIES (MINIMUM) SAWN TIMBER (UNO)
          AS 5100        BRIDGE DESIGN                                                                 B)    ALLOW OF LIKELIHOOD OF FLOW WITHIN THE WATERWAY: EXISTING WATERWAY ARE
          BCA           BUILDING CODE OF AUSTRALIA (NATIONAL CONSTRUCTION CODE)                              FLOODED MULTIPLE TIMES PER YEAR. PROTECT CONSTRUCTION EQUIPMENT AND                                     T9      WASHERS SHALL BE PROVIDED UNDER ALL NUTS AND BOLT HEADS (EXCEPT CUP-HEAD
                                                                                                             WORKS.                                                                                                          BOLTS) BEARING AGAINST TIMBER AS FOLLOWS:
    G6    ANY DISCREPANCY SHALL BE REFERRED TO THE SUPERINTENDENT FOR A DECISION BEFORE                                                                                                                                          BOLT SIZE      WASHER
          PROCEEDING WITH THE WORK.                                                                   CC2. NO WORK TO COMMENCE ON SITE UNTIL:                                                                                    <=M12           50X50X3.0mm
                                                                                                                                                                                                                                    M16         57X57X4.0mm
                                                                                                           - OFFICIAL PRE-START MEETING HELD AND PRE-START MEETING MINUTES ISSUED
    G7    ALL PROPRIETARY PRODUCTS NOT DEEMED TO COMPLY WITH THE BCA SHALL HAVE                                                                                                                                                     M20         65X65X5.0.mm
                                                                                                           - CONTRACTOR'S MANAGEMENT PLANS SUBMITTED (SITE, TRAFFIC, ENVIRONMENT,
          THIRD-PARTY CERTIFICATION WITH RELEVANT TESTING AND SIGN-OFF BY AN RPEQ ENGINEER.                                                                                                                                       >M20           75X75X6.0mm
                                                                                                           SAFETY) FOR SUPERINTENDENT'S REVIEW.
          PROPRIETARY PRODUCTS INCLUDES PREFABRICATED TRUSSES, LIGHT-GAUGE STEEL
          FRAMING, FLOORING PRODUCTS, RECYCLED TIMBER AND PLASTICS, BALUSTRADES, SCREENS,                                                                                                                            T10     X….. INDICATES M12DIA ANCHOR ROD/BOLT
          SHADE FABRICS, JOINERY, PARTITIONS AND OPERABLE WALLS.
                                                                                                                                                                                                                     T11     [X]….. INDICATES M16DIA ANCHOR ROD/BOLT
    G8    REFER TO ARCHITECTS DRAWINGS FOR DETAILS OF ALL GROOVES, FILLETS, HOBS, DRIP
                                                                                                      DRIVEN PILES:
          GROOVES AND THE LIKE.                                                                                                                                                                                      T12     SB…. INDICATES STRAP BRACE ROOF BRACING FIXED TO TOP OF EACH JOIST WITH 2
                                                                                                      P1.    PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH AS2159.                                                           SCREWS. BEND STRAP BRACING OVER AT ENDS, FIX WITH 2 SCREWS TO TOP OF JOIST
    G9     GIVE AT LEAST 24 HOURS NOTICE OF AN INSPECTION BEING REQUIRED FOR :                                                                                                                                               AND 4 SCREWS TO SIDE FACE OF SUPPORTING MEMBER. ALL ROOFS TO BE BRACED.
                                                                                                      P2.    CONSTRUCTION CONSTRAINTS: AVOID LOADING EXISTING REVETMENT WALLS.
          - PILING
          - JETTY FRAMING (TIMBER)                                                                                                                                                                                   T13     ALL FASTENERS ARE TO BE GRADE A4-70 STAINLESS STEEL IN ACCORDANCE WITH
                                                                                                      P3.    DESIGN LOADS: PILES TO ACHIEVE GEOTECHNICAL CAPACITIES (VERTICAL &                                              ISO-3506-1. EXTERNAL ANCHORS WHERE SUBJECT TO SALT AIR SHALL BE STAINLESS
          - BRACING AND TIE DOWN
                                                                                                             HORIZONTAL) SHOWN ON THE DRAWINGS WHERE PROVIDED.                                                               STEEL A4-70:
    G10   ALL FABRICATION SHOP DRAWINGS SHALL BE PROVIDED TO THE ENGINEER FOR REVIEW AND                                                                                                                                          -SCREWS TO BE NO.14 TYPE 17 WITH 50MM EMBEDMENT (UNO)
                                                                                                      P4.    REQUIRED PILE POSITION TOLERANCES:                                                                                   -ALL JOIST HANGERS, FRAMING ANCHORS, TRIPLE GRIPS AND THE LIKE, SHALL BE
          COMMENT IN A3 HARDCOPY OR PDF FORMAT.
                                                                                                                                                                                                                                  STAINLESS STEEL. TO BE MANUFACTURED BY PRYDA OR APPROVED
                                                                                                             PLAN POSITION: +/- 50mm AT UNDERSIDE OF EACH GROUND BEAM.                                                            EQUIVALENT, WITH 5 NO. 2.8mm DIA X 30MM
    G11   ABBREVIATIONS (GENERAL):
                                                                                                             PILE VERTICALITY:                                                                                                    NAILS EACH LEG MINIMUM. INSTALL AS PER MANUFACTURERS SPECIFICATION.
          NTS      NOT TO SCALE
                                                                                                             - WITHIN 4% FOR ALL PILES
          UNO      UNLESS NOTED OTHERWISE
          NSOE     NOT SHOWN ON ELEVATION                                                                                                                                                                            T14     PROVIDE BLOCKING OVER SUPPORTS AT 1800 MAX CRS IN ACCORDANCE WITH AS 1684
                                                                                                      P5.    DO NOT FOUND PILES HIGHER THAN TOE LEVELS ON DRAWINGS, UNLESS APPROVED                                          FOR TIMBER BEARERS AND JOISTS WITH D/B >= 4.
          NSOP     NOT SHOWN ON PLAN
                                                                                                             BY BOTH THE SUPERINTENDENT AND THE ENGINEER. THE SUPERINTENDENT SHALL
          TYP      TYPICAL
                                                                                                             SEEK ADVICE FROM THE ENGINEER AS REQUIRED.                                                              T15     FOR JOISTS WITH SPAN >3000 AND BOTTOM OF JOIST UNRESTRAINED BY CEILING
          (O)      OVER
          (U)      UNDER                                                                                                                                                                                                     DIAPHRAGM:
          CRS      CENTRES                                                                                                                                                                                                        -PROVIDE 1 ROW OF BLOCKING BETWEEN EACH JOIST AT
          NOM      NOMINAL                                                                                                                                                                                                            MIDSPAN FOR SPANS < 4200mm
          CFW      CONTINUOUS FILLET WELD                                                             ALUMINIUM:                                                                                                                  -PROVIDE 2 ROWS OF BLOCKING BETWEEN EACH JOIST AT
                                                                                                                                                                                                                                      THIRD POINTS FOR SPANS >4200mm
                                                                                                      A1.    ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH BEST PRACTISE ALUMINIUM
                                                                                                             FABRICATION AND THE CURRENT AUSTRALIAN STANDARD AS 1664.                                                T16     FIXING LOCATIONS TO BE FIXED ACCORDING TO THE FOLLOWING MINIMUM PACINGS
    DESIGN CRITERIA                                                                                   A2.    ALUMINIUM SECTIONS SHALL COMPLY WITH AS 1734, AS 1886 OR AS 1867.                                               (D = FIXING SHANK DIA. IN mm):
                                                                                                      A3.    ALL WELDING SHALL COMPLY WITH AS 1665.                                                                          BOLTS       4D  EDGE DISTANCE TO BOTH EDGES IN DIRECTION OF SHEAR LOAD
    DC1 THE STRUCTURAL ELEMENTS HAVE BEEN DESIGNED FOR THE FOLLOWING LIVE LOADS                       A4.    ALL WELDING SHALL BE CARRIED OUT USING ARGONGAS SHIELDING. WELD                                                            5D   PITCH BETWEEN BOLTS
        IN ACCORDANCE WITH AS 1170.1: LIVE LOAD REDUCTIONS ARE NOT APPLICABLE.                               CONSUMABLES SHALL BE COMPATIBLE WITH BOTH PARENT ALLOYS IN ACCORDANCE                                                      5D   EDGE DISTANCE FROM END OF ELEMENT
        ELEMENT            UDL         CONCENTRATED                                                          WITH AS AS 1665. FOR 6063-T6 USE 4043 FILLER WIRE. PLATE-TO-EXTRUSION ALLOYS                                               13D MINIMUM OVERALL ELEMENT DEPTH
        DECK               2.0kPa      2.7KN                                                                 SHALL BE WELDED USING APPROPRIATE FILLERS IN ACCORDANCE WITH WTIA
                                                                                                             TECHNICAL NOTES WHERE NOT COVERED BY AS 1665.
    DC2 WIND LOADS HAVE BEEN DETERMINED IN ACCORDANCE WITH AS 1170.2 BASED ON:                                                                                                                                        MINIMUM SPACING, EDGE & END DISTANCES FOR NAILS AND SCREWS
                                                                                                      A5.    ALL WELDS SHALL BE A MINIMUM 5mm CONTINUOUS FILLET WELD ALL ROUND,
        IMPORTANCE LEVEL            2                                                                        UNLESS NOTED OTHERWISE.
        REGION                      B                                                                                                                                                                                                                   MINIMUM DISTANCE
                                                                                                      A6.    ALUMINIUM EXTRUSIONS SHALL BE STRUCTURAL GRADE ALLOY:- EXTRUSIONS 6063-T6
        ULTIMATE WIND SPEED         51 m/s                                                                   UNLESS NOTED OTHERWISE.
        SERVICEABILITY WIND SPEED   39.0 m/s                                                                                                                                                                           SPACING TYPE        HOLES FOR                      HOLES FOR
                                                                                                      A7.    ALUMINIUM PLATE IS TO BE WROUGHT GRADE ALLOY 5083 H116.
        TERRAIN CATEGORY           2.5                                                                                                                                                                                                     NAILS NOT                      NAILS PREBORED SCREWS
                                                                                                      A8.    ALL STEEL AND STAINLESS STEEL BOLTS AND ALL OTHER FIXINGS MUST BE ISOLATED
                                                                                                                                                                                                                                           PREBORED                       TO 80% DIA.
                                                                                                             FROM ALUMINIUM USING NYLON OR SIMILAR APPROVED PACKERS/GASKETS, AND
    DC3 EARTHQUAKE LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 1170.4 BASED                                                                                                                                      END DISTANCE          20D                               10D        10D
                                                                                                             WASHERS WITH SHANK COLLARS.
        ON:                                                                                                                                                                                                            EDGE DISTANCE          5D                                 5D        5D
                                                                                                      A9.    SHOP DETAIL DRAWINGS ARE TO BE SUBMITTED TO THE ARCHITECT AND ENGINEER
        ACCELERATION COEFFICIENT    0.06                                                                                                                                                                               ALONG-GRAIN SPACING   20D                                10D       10D
                                                                                                             FOR REVIEW. APPROVAL IS TO BE OBTAINED FROM THE COUNCIL, THE ARCHITECT AND
        SITE FACTOR                1                                                                                                                                                                                   CROSS-GRAIN SPACING    10D                               3D         3D
                                                                                                             THE ENGINEER, PROIR TO COMMENCING FABRICATION.
        IMPORTANCE LEVEL           1
        STRUCTURE TYPE
        DESIGN CATEGORY            EDC1
                                                                                                      TEMPORARY WORKS:
    DC4 FIRE RESISTANCE LEVELS OF STRUCTURAL ELEMENTS HAVE BEEN TAKEN AS FOLLOWS:
        ELEMENT        FRL (mins)
        COLUMNS        -/-/-                                                                          T1.    MAINTAIN THE WORKS IN A SAFE CONDITION. ENSURE STRUCTURES ARE NOT
        BEAMS         -/-/-                                                                                  OVER-STRESSED AT ANY TIME. TEMPORARY ROAD SURFACES SHALL BE TRAFFICABLE
        WALLS         -/-/-                                                                                  AT ALL TIMES. POTHOLES ETC SHALL BE MONITORED AND REPAIRED.

    DC5 DETERMINATION OF DESIGN LOADING FOR NON-STRUCTURAL ELEMENTS SUCH AS
                                                                                                                                                                                                                                                                                                                                      NOOSA COUNCIL
        CEILING AND CLADDING SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR                    T2.    CONTRACTOR'S RPEQ TO CERTIFY DESIGN AND CONSTRUCTION FOR TEMPORARY

    DC6 FLOOD LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS 5100 WITH NOMINAL
                                                                                                             WORKS: STRUTS, PROPPING, FORMWORK STRIPPING AND PROPPING PROCEDURES, TIE
                                                                                                             BACKS, EXCAVATION SHORING, PROTECTION WORKS, DE-WATERING SYSTEMS,
                                                                                                             FORMWORK, EARLY LOADING OF STRUCTURES AND THE LIKE.
                                                                                                                                                                                                                                                                                                                                      APPROVED PLAN
        FLOOD VELOCITY TO BE CONFIRMED BY HYDRAULIC REQUIREMENTS AS FOLLOWS:
        -V100 = 1m/s.
                                                                                                                                                                                                                                                                                                                                       132002.220261.01
    DC7 DESIGN LIFE IN ACCORDANCE WITH AS 4997 FOR THE APPLICABLE FACILITY CATEGORY:
        2 SMALL CRAFT FACILITY - 25 YEARS.
                                                                                                                                                                                                                                                                                                                                     25 SEPTEMBER 2026
                                               CONSTRUCTION
     © THIS DRAWING IS PROTECTED                                                              ASSOCIATED CONSULTANTS                                                                                                                                    PROJECT                                                               DRAWING TITLE
     UNDER COPYRIGHT IN
     ACCORDANCE WITH
     AGREEMENT BETWEEN
     LODESTAR MERIDIAN PTY LTD
                                                                                                                         NOOSA JETTY SERVICES
                                                                                                                         Email: [email protected]
                                                                                                                         Phone: 0408 137 526
                                                                                                                                                                                        Long View                                                        EXISTING JETTY REPLACEMENT
                                                                                                                                                                                                                                                         31 SALTWATER AVENUE, NOOSAVILLE, 4566, QLD
                                                                                                                                                                                                                                                                                                                               STRUCTURAL NOTES SHEET
     T/AS LONG VIEW CONSULTING
                                                                                                                                                                         L              Consulting Engineers
                                   REVISIONS




     ENGINEERS AND THE CLIENT AS
     NAMED HEREIN. EXCLUSIVE
                                               1   CONSTRUCTION ISSUE       C3     F.M.
                                                                                                                                                                                        Lodestar Meridian Pty Ltd T/as Long View Consulting Engineers   DRAWN             CHECKED          APPROVED          DATE             SCALE BAR                             DRAWING SCALES          DRAWING SIZE
     USE IS GRANTED UNDER THE
     AGREEMENT ONLY FOR THE                    1   CONSTRUCTION ISSUE       C2     F.M.                                                                                  V              Post:     PO Box 963 Cooroy QLD 4563
                                                                                                                                                                                                                                                                   N.N.             N.N.                        21/07/2026                                                            1:1    A1 ORIGINAL
                                                                                                                                                                                        ABN:      87 711 552 832
     PROJECT. THIS DRAWING SHALL
     NOT BE CONSTRUCTED UNLESS                 1   CONSTRUCTION ISSUE       C1     F.M.                                                                                                 Mobile: 0414 681 676
                                                                                                                                                                                                                                                        DESIGNED          CHECKED                            RPEQ / Cert.     PROJECT NUMBER                        DRAWING NUMBER          REVISION
                                                                                                                                                                                        Email:    [email protected]
                                                                                                                                                                                                                                                                                                                                                21.101-016                           S02               C3
     DESCRIBED AS "CONSTRUCTION
     ISSUE".                                   No. DESCRIPTION              REV.   APP.                                                                                                 Internet: www.longviewconsulting.com.au                                    F.M.             F.M.                              19951


Document Set ID: 25190268
Version: 1, Version Date: 21/09/2026

Used in these records

About this file

File size
2.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plans - 132002.220261.1 (As Published).pdf · 2.3 MB (large file)