NOOSA COUNCIL
APPROVED PLAN A B
A05-22 A05-22
132005.1133.8 28 NOV 2018 T.O
.W
.1
7. 9
00
RL 16.000 RL 16.000
601 602 603 604 605 606 BUSHFIRE PROTECTION NOTE
GA
TE 7695 5300 7600 5300 7695 BAL 12.5 MINIMUM CONSTRUCTION IN
ACCORDANCE WITH AS3959-2009 AND
RL
GATE GATE GATE GATE GATE AMENDMENTS.
CO 15
. 60 REFER TO CONSTRUCTION NOTES, DOOR AND
UR 0
T
RO YA 2400
WINDOW SCHEDULES, SCHEDULE OF FIXTURES
FO CK RD AND FINISHES & SPECIFICATION
O R E LIN COURTYARD COURTYARD COURTYARD COURTYARD COURTYARD
ENVER MERED C
GI FLO G H 09
NE W EN AN
ER TO CY NE T.O.S. 18.250 07-02 MECHANICAL
SD C L
ET IVIL EXHAUST RISER
AIL WITH FINISH RB02
S
FALL
FALL
FALL
FALL
FALL
CJ CJ SCR08 CJ SCR08 SCR08 CJ CJ
TE
RR
01 ACE 6A CL
CL
6A
TERRACE TERRACE
EN
01 TERRACE TERRACE TERRACE 01
LDY LDY
SCR07
RL W W W
SCR03
SCR03
RD
GARDEN
15 6-19 6-22 CL 6-24
. 50
GA
0 WM WM
W W
W 6-20 W 6-23 W
6-18 6-21 6-25
5040
D
D
FRL 90/90/90
FRL 90/90/90
AWN01
BED 1 BED 1 BED 1
KITCHEN
KITCHEN
W
D W D W W D 6-02
6-50 6-28 6-37 6-27 6-26 6-21
LIVING LIVING LIVING LIVING LIVING
6C DW DW 6C
W SHR P/ SHR P/ SHR
5- 0
1
W
6-17 UNIT 611 D
6-49 UNIT 612 MW UNIT 613 D
6-36 MW UNIT 614 D
6-22 UNIT 615
UNIT TYPE 8A WIR ENS UNIT TYPE 7A R UNIT TYPE 18A WIR ENS R UNIT TYPE 7A ENS WIR UNIT TYPE 8A
D D
DINING 6-41 DINING 6-32 DINING
L L
W C C C W
6-16 SFL 16.300 6-03 RL 16.000
D D D
M.P.R. M.P.R.
SHR BTH
SHR BTH
SHR BTH
C C
C WC BATH 05 WC BATH BATH WC C
DW 07-09 DW DW
05-23 MW D D D MW D D D D D MW 05-23
6-48 6-47 6-42 05 6-35 6-34 6-31 6-24 6-23 06
10190
W 07-09 W
06 07-09
KITCHEN D KITCHEN KITCHEN
D
D
6-15 C D C D 6-04
07-09 6-46LDY 6-33LDY LDY6-25
WC ENS ENS WC
SCR05
P R STUDY WM D D P R STUDY WM D D WM STUDY R P
6-43 6-40 SHR SHR 6-29 6-30
ROBE C C ROBE ROBE C C ROBE C C ROBE
D D D D
6-28 W
W D D 6-44 6-39 D 6-27 D D 6-05
6-14 6-51 6-45 6-38 6-26 6-20
RW + CTR 50
RW + CTR 50
RW + CTR 50
FRL 90/90/90
FRL 90/90/90
FRL 90/90/90
BED 2 BED 3 BED 1 BED 2 MEDIA BED 1 BED 3 BED 2
ROBE
ROBE
D D
6-16 6-18
300
16.
D D D
6E 6E
W
6-13
6-15 W
6-12
W
6-11
W
6-10
S-1.4
6-17 W
6-09
W
6-08
W
6-07
6-19 W
6-06
FLOOR PLAN LEGEND
TERRACE WALKWAY D D
2450
FALL D D FALL FALL FALL TERRACE
FALL
FALL
6-13 6-12 6-09 6-08
02
FALL
02
FALL
AWN1 AWNING
05 BG BOX GUTTER
CL 07-05 FE HC S-1.3 FE CL
E H BO 1200 HIGH BOLLARD (FINISH TO
D DP DP D
6F 6-14 DP DP 6-07 6F SPECIFICATION)
SCR08 D D SCR08 BR BIKE RACK
DP 6-11 6-10 DP BTFW BUCKET TRAP FLOOR WASTE
SCR04 SCR04
UP 17 LIFT 17 UP C CUPBOARD (REFER TO INTERIOR DETAILS)
STAIR 01 16
06 16 01 STAIR CJ CONTROL JOINT
VOID
VOID
3790
02 15 15 02
HR06
HR04
HR04
HR06
06-02
BATTER
06-01 03 14 H 16.200 H 14 03 CON. TROWEL FINISHED CONCRETE
04 13 13 04 F01
17 RISERS D DUCT
@ 180mm 05 12 12 05 17 RISERS DP DOWN PIPE
06 06 @ 180mm
DW DISHWASHER UNDER
G
D
RAKIN
07 08 09 1011 1110 09 08 07 00 DOOR NUMBER
6G 6G DR DRAIN
ECR ENTRY CARD READER
16.020 16.020
FE FIRE EXTINGUISHER
FHR FIRE HOSE REEL
FRL FIRE RESISTANCE LEVEL
FW FLOOR WASTE
GT GRATED TRENCH
601 602 603 604 605 606 H FIRE HYDRANT
HC HOSE COCK
RAK
HR HANDRAIL
ING
HP HYDRAULIC PIPES
HWU HOT WATER UNIT
MR MECHANICAL RISER
MW MICROWAVE
NBN NBN BOARD
ING P / PTY PANTRY
RAK PO PLANTER OUTLET
R REFRIGERATOR SPACE (-INT = INTEGRATED)
RAKING RO ROOF OUTLET
RL 0.00 REDUCED LEVEL
SB SWITCH BOARD
SCR SCREEN
A B
A05-22 See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 132005.1133.13Related documentApplication case desk ↗