Council archive · source document
SUPERSEDED - Compiled Approved Plans - 132005.1133.13
Plans and drawings: the text below has words only, no drawings.
Very large file (113 MB): may take a few minutes to open.
Original PDF page 61, section 1. The text section number identifies this passage in the reader.
-
NOOSA COUNCIL
A B
APPROVED PLAN
05-15 05-15
132005.1133.8 28 NOV 2018
1601 1602 1603 1604 1605 1606
8340 7800 7800 7800 8340
VERTICAL MECHANICAL EXHAUST
LINE OF LEVEL 1 ABOVE RISER
DRAIN TO THE BOTTOM OF RISER
RL 31.180 VERMIN PROOF MESH TO BE
PROVIDED AT DUCT OPENINGS
SPOON DRAIN
LINE OF LEVEL 1 ABOVE LINE OF LEVEL 1 ABOVE
620 2485
16A MECHANICAL EXHAUST
16A
8 9 10 10 9 8
17 RISERS @ PLENUM 17 RISERS @
180mm 180mm
RL 31.180 RL 31.180
7 7
6 11 11 6
3960
STORE 1611 SPOON DRAIN 5 12 12 5 SPOON DRAIN
HR06
HR06
4 13 13 4
3 14 SELECTED WATERPROOF MEMBRANE 14 3
02 2
1
15
16
LIFT TO ALL SUB-EARTH WALLS 15
16
2
1
LINE OF LEVEL 1 ABOVE
07-02 UP 17 LINE OF LEVEL 1 ABOVE 16 17 UP
5185
CART
3300 3520 STAIR 16-01 SUMP STAIR 16-02 620 3005
RL 31.230
16B RL 31.230
16B
D F. H. R. F. H. R.
D
13 13 16-01 16-05
SPOON DRAIN S-B.2 SPOON DRAIN
6000
RL 31.215 RL 31.215 MECHANICAL DUCT SHOWN
13
SPARE STORE D
13
CART 13 MSB 13 DASHED FOR CLARITY. REFER
1611 16-02
TO MECHANICAL ENGINEERS
DRAWINGS FOR DETAIL
620 3200 3000
GALVANISED
6115
CART CHAIN WIRE
FENCE & GATE
FALL
DOTTED LINE INDICATES
1532 EXTENT OF RENDERED D 13 13 13
13 BLOCKWORK 16-03 1x1100l GENERAL WASTE BIN
6000
1x1100l RECYCLE BIN
5400
FALL
CART 13 FW
FALL
D D
13
15-143 15-144 SPOON DRAIN
HP HP REFUSE HP
3390 90 3520 190
16C CART BOL
16C
RL 31.215 HC
SECURITY DOOR
CONNECTION 1631 1631 1633 1633 1632
VENTILATED
13 13 HP
TO BLOCK 16 1611 13 1
5800
D D
FW 15-145 BASEMENT
16-143
G D D D D D D LANDSCAPING
13
13
13
C 16-138 16-139 DOTTED LINE INDICATES EXTENT 16-04 16-140 16-141 16-142
G
VENTILATED SECURITY DOOR
05-11 OF RENDERED BLOCKWORK AIR IN GRILL IN WALL REFER
VENTILATED SECURITY DOOR
300 TO MECHANICAL ENGINEER.
2500 1500 2800 1350 2200 2500 2500 600 2710 2390 190 2510 190 2160 2500 2500 300 1000 4000 3000 VERMIN PROOF MESH TO BE
2500 3000 190 PROVIDED AT DUCT OPENINGS
RL 31.215 RL 31.215
RL 31.300
6300
8200
1723
5800
5800
D D
16-144 FW FALL FALL FW 16-145
1514 1514 C ALL PARKING DIMENSIONS TO COMPLY C
05-16 WITH AS 2890.1 & AS 2890.6 05-16
CONNECTION TO
BLOCK 17
3000 2500 2650 2650 2500 2650 2650 2500 2650 2650 2500 2650 2650 2500 3000 BASEMENT C
SECURITY DOOR
05-21
VENTILATED
D
1613 1613 SPARE 1612 1612 1624 1624 1623 1623 1622 1622 1621 1621 1614 1614 17-61
LANDSCAPING
LINE OF LEVEL 1 ABOVE
16D 16D FLOOR PLAN LEGEND
SPOON DRAIN HC HC
LINE OF LEVEL 1 ABOVE LINE OF LEVEL 1 ABOVE
FALL
RL 31.215 AWN1 AWNING
5400
BG BOX GUTTER
STORE 1514
BO 1200 HIGH BOLLARD (FINISH TO
SPECIFICATION)
5440
BR BIKE RACK
SPOON DRAIN
GALVANISED CHAIN WIRE
SPOON DRAIN LANDSCAPING BTFW BUCKET TRAP FLOOR WASTE
FENCE AND GATE C CUPBOARD (REFER TO INTERIOR DETAILS)
RL 31.215 RL 31.215 AIR IN GRILL IN WALL REFER
TO MECHANICAL ENGINEER. CJ CONTROL JOINT
VERMIN PROOF MESH TO BE CON. TROWEL FINISHED CONCRETE
PROVIDED AT DUCT OPENINGS D DUCT
1050
STORE 1613 SPARE STORE STORE 1612 STORE 1624 STORE 1623 STORE 1622 STORE 1621 STORE 1614 DP DOWN PIPE
DW DISHWASHER UNDER
16E 16E D
00 DOOR NUMBER
DR DRAIN
SELECTED WATERPROOF MEMBRANE MECHANICAL DUCT SHOWN ECR ENTRY CARD READER
TO ALL SUB-EARTH WALLS DASHED FOR CLARITY. REFER FE FIRE EXTINGUISHER
TO MECHANICAL ENGINEERS FHR FIRE HOSE REEL
DRAWINGS FOR DETAIL FRL FIRE RESISTANCE LEVEL
FW FLOOR WASTE
GT GRATED TRENCH
H FIRE HYDRANT
HC HOSE COCK
A B HR HANDRAIL
1601 05-15 1602 1603 05-15 1604 1605 1606 HP
HWU
HYDRAULIC PIPES
HOT WATER UNIT
MR MECHANICAL RISER
MW MICROWAVE
NBN NBN BOARD
P / PTY PANTRY
PO PLANTER OUTLET
R REFRIGERATOR SPACE (-INT = INTEGRATED)
RO ROOF OUTLET
RL 0.00 REDUCED LEVEL
SB SWITCH BOARD
SCR SCREEN
SC STRUCTURAL COLUMN
SDO SPOON DRAIN OUTLET
S-B.1 SIGN NUMBER - REFER TO DRAWING A13-01
SF SECURITY FENCE
01 FLOOR PLAN SHR
SHR BATH
SHOWER
SHOWER OVER BATH
- BLOCK 16 - BASEMENT SCALE 1:100
BUSHFIRE PROTECTION NOTE SM
SP
SMOKE SEALS TO DOOR FRAME
SPITTER
SFL 0.00 STRUCTURAL FLOOR LEVEL
BAL 29 MINIMUM CONSTRUCTION IN ACCORDANCE WM WASHING MACHINE
WITH AS3959-2009 AND AMENDMENTS. W WINDOW NUMBER
REFER TO CONSTRUCTION NOTES, DOOR AND 00
NOTE :
WINDOW SCHEDULES, SCHEDULE OF FIXTURES REFER TO ENGINEER'S DRAWINGS FOR STRUCTURAL DETAILS
AND FINISHES & SPECIFICATION
PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
notes : issue amendment log by date issue amendment log by See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 132005.1133.13Related documentApplication case desk ↗
About this file
- File size
- 113 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.