RETAIN EXISTING FACADE RETAIN EXISTING FACADE
FINISH. MAKE GOOD AND FINISH. MAKE GOOD AND
REPAIR ANY DAMAGED PAINT REPAIR ANY DAMAGED PAINT
HOTEL ROOF FINISH FINISH
20.820 m
RETAIN EXISTING FACADE
10040
FINISH. MAKE GOOD ANY
FIRST FLOOR DAMAGED FINISH
14.880 m
NEW LIQOURLAND PYLON
WITH DIRECTIONAL TEXT
NEW FRAMED GLAZED
WINDOWS AND DOORS
GROUND FLOOR MATCHING EXISTING
10.780 m 'LIKE FOR LIKE'
BEER GARDEN
10.000 m
NEW FENCE TO SOUTHERN
BEER GARDEN MATCHING
EXISTING
2 PROPOSED ELEVATION - POINCIANA STREET.
-- 1 : 100
RETAIN EXISTING FACADE
FINISH. MAKE GOOD AND
REPAIR ANY DAMAGED
PAINT FINISH
HOTEL ROOF
20.820 m
FESTOON LIGHTS HUNG PE-01 PERGOLA PE01 PERGOLA
10040
FROM PERGOLA STRUCTURE WITH STRUCTURE WITH
FIRST FLOOR STRUCTURE LIGHTWEIGHT ROOF LIGHTWEIGHT ROOF
14.880 m
UM01 PE01 PE01 UM01 BW-01
GROUND FLOOR
10.780 m
1200
RN-01 RN-01 RN-01 RN-01 RN-01 RN-01 RN-01 RN-01
BEER GARDEN
10.000 m BUS SHELTER PA-03 PA-03 PA-03 PA-03 PA-03
HYDRANT PA03 TO LOWER BA-01 CLEAR GLASS BA-01 CLEAR GLASS
PARKING
9.800 m 1 PROPOSED ELEVATION - DIYAN STREET BOOSTER ON
CONCRETE SLAB
WALL ENTRY GATE BALUSTRADE WITH TIMBER
POST. SOLID NO GAP
-- 1 : 100
NEW PERGOLA STRUCTURE
IN TIMBER FINISH WITH TRANSLUCENT LASERLITE ROOF TM-04 AW-01
ALL EXISTING ROOF TO BE CLEANED AND COLOURBOND ROOF RETAIN EXISTING FACADE RETAIN EXISTING FACADE
MADE GOOD. APPLY NEW PA-18 FINISH OVER BAR AREA AW-02 FINISH. MAKE GOOD AND FINISH. MAKE GOOD AND
TO UNDERSIDE OF ROOF REPAIR ANY DAMAGED PAINT REPAIR ANY DAMAGED PAINT
NEW CLEAR GLASS BALUSTRADE FINISH FINISH
HOTEL ROOF BA-01 WITH TIMBER POSTS BA-01 RL +20,820
20.820 m RL +20,752
1:2
1:2
1:2
PA-18
RL +17,936
1 :2 PA-18 RL +18,216
RL +17,936
RL +17,936 RL +17,829
5940
EXISTING ROOF TO BE
RL +16,658
CLEANED AND MADE GOOD
RL +15,868 RL +15,680
PA-18 RL +15,380 PA-20 PA-20
1:3
FIRST FLOOR RL +15,208
14.880 m RL +14,505
RL +14,413
1:11
AW-02 AW-02
AW-02
11020
RL +13,580 PA-18 RL +13,932
1:4 RL +13,636
AW-02
1:4
6080
RL +13,305
4100
Autodesk Docs://The Australian Venue Co../AVC0013 - Royal Mail Hotel_Cloud.rvt
GROUND FLOOR PA-18
D
10.780 m EX FE-01
BEER GARDEN
980
10.000 m
PARKING
9.800 m CLEAN AND MAKE GOOD CLEAN AND MAKE GOOD NEW 2400MM H PERGOLA STRUCTURE. NEW 2400MM H PERGOLA STRUCTURE. NEW 1800MM H FE-01 FENCING
EXISTING FENCE. APPLY NEW EXISTING FACADE. APPLY NEW POSTS IN PC-01 POWDERCOATED POSTS IN PC-01 POWDERCOATED
NEW RENDER FINISH TO EXISTING
PA-18 PAINT FINISH PA-18 PAINT FINISH ALUMINIUM WITH AW-02 ROOF SHEETING ALUMINIUM WITH AW-02 ROOF SHEETING
FACADE IN WARM WHITE TONE
3 PROPOSED ELEVATION . PLANNING APPROVAL
-- 1 : 100 NOT FOR CONSTRUCTION
0 0.5 2.0 4.0 5.0
SCALE IN METRES
Rev Description By Date Project Name Project No. Drawn
1 FOR COORDINATION DD 30.01.2023
AVC0013 Author
2 TOWN PLANNING ISSUE DD 16.06.2023
ROYAL MAIL HOTEL
Date Checked
3 TOWN PLANNING ISSUE DD 05.07.2023 Site Address
SEPT 2022 Checker
4 TOWN PLANNING ISSUE DD 07.07.2023
11/04/2024 1:09:20 PM
120 POINCIANA AVE, TEWANTIN QLD 4565, AUSTRALIA Scale Certified
5 REVISED COLES TOWN PLANNING ISSUE DD 05.09.2023 1 : 100 @ A1 R. OVCARIC
6 FOR INFORMATION DD 21.03.2024 Drawing Title Drawing No. Revision
7 DA FOR INFORMATION DD 11.04.2024
PROPOSED EXTERNAL TP10 7
ELEVATIONS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.