Log in to see the plans as drawnPerformance outcomes Acceptable Outcomes
Installation of hydrant
PO1 AO1.1
Fire hydrants are installed and located to enable QFES Fire hydrant placement and technical requirements for
vehicles to access water safely, effectively and efficiently. residential streets and common access ways within common
private title are in accordance with:
(a) Australian Standard (AS) 2419.1 – 2005 Fire hydrant
installations; and
(b) QFES: Fire Hydrant and vehicle access guidelines for
residential, commercial and industrial lots.
AO1.2
Fire hydrant placement and technical requirements for
commercial and industrial streets and access ways within
streets serving commercial properties, such as factories,
warehouses and offices, are in accordance with:
(a) Australian Standard (AS) 2419.1 – 2005 Fire hydrant
installations; and
(b) QFES: Fire Hydrant and vehicle access guidelines for
residential, commercial and industrial lots.
Editor’s Note— Design and technical requirements for
infrastructure from third party providers are to be in addition to,
and integrated where possible, into the overall design, built
form and landscaping requirements for the development.
Road technical standards
PO2 No acceptable outcome provided.
Road widths and construction within the development are
adequate for QFES vehicles to gain access to a safe working area Editor’s Note—Roads should be designed and constructed in
close to buildings and near water supplies whether or not on accordance with Road Planning and Design manual 2nd edition.
street parking spaces are occupied.
**FINAL DRAFT Post Consultation 2019**
Page 2 of 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.