Original source · versioned page text
2019-12-11 SM Agenda - Item 1 - Attachment 7 - Final New Noosa Plan - Part 8-10 Schedule Appendix - Clean version
The original of this document is very large (23.3 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnPerformance outcomes Acceptable Outcomes
PO5
Development does not place residents at risk of exposure to No acceptable outcome provided
noise levels, air emissions or odour levels that would cause
unacceptable health risks
PO6 AO6.1
The design of the caretaker’s accommodation, dwelling unit or The residence can be secured so that persons other than the
rural workers' accommodation achieves an acceptable level of residents cannot gain direct access.
residential amenity for residents of the use, including security,
visual and acoustic privacy and access to private open space. AO6.2
Bedrooms and living rooms of the caretaker’s accommodation,
dwelling unit or rural workers' accommodation do not adjoin, and
face away from, noise generating activities conducted on the site
or adjoining sites.
AO6.3
The caretaker’s accommodation or dwelling unit is provided with a
patio, balcony, verandah, deck or garden with an area of not less
than 15m² with a minimum horizontal dimension of at least 2.5
metres.
AO6.4
Rural workers' accommodation is provided in a permanent
habitable structure with, as a minimum:
(a) sleeping quarters;
(b) bathroom facilities;
(c) living rooms separate to sleeping quarters;
(d) running drinking water supply, plumbed effluent disposal
and power supply.
or
AO6.5
Where rural workers' accommodation takes the form of temporary
or transportable accommodation:
(a) ablutions and waste disposal are provided on site; and
(b) employees stay no longer than six weeks.
Editor’s Note — depending on the nature of accommodation and
the number of people accommodated special requirements
pursuant to the Building Act 1975 or the Workers' Accommodation
Act 1952 may apply to rural workers' accommodation.
AO6.6
The residential use is setback at least 3 metres from any waste
servicing area.
AO6.7
Caretaker’s accommodation and rural workers' accommodation
is separated by at least 150 metres from:
(a) the Resource Area/ Processing Area and operational area
of any Key Resource Area;
(b) any intensive animal industry;
(c) any high impact industry.
**FINAL DRAFT Post Consultation 2019**
Page 4 of 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.