Log in to see the plans as drawnPerformance outcomes Acceptable Outcomes
PO4 AO4.1
Visitor accommodation is located such that it preserves the safety Accommodation adjacent to or within 50 metres of an existing
of guests and does not impact on the function of infrastructure electricity substation incorporates noise attenuation measures to
including: mitigate noise impacts.
(a) the major road network;
AO4.2
(b) the North Coast railway line;
Buildings and structures (including swimming pools, sheds,
(c) existing and future electricity supply infrastructure; and tennis courts and outbuildings) are not constructed under
(d) water supply and waste water treatment. overhead electricity transmission lines, or within electricity
easements.
AO4.3
Accommodation:
(a) within a designated transport noise corridor; or
(b) within 100 metres of an existing electricity substation—
incorporates noise attenuation measures to mitigate noise
impacts and guests are not accommodated in lightweight
shelters (such as tents, yurts, recreational vehicles, or relocatable
dwellings).
Editor’s Note— The State Planning Policy Interactive Mapping
System can be used to find out if a property is located in a
designated transport noise corridor or close to electricity
infrastructure.
AO4.4
Accommodation within a water catchment area relies on minimal
clearing of natural vegetation, earthworks, and movement of
sediments or nutrients from the site and any onsite disposal of
effluent is to a secondary treatment standard.
Editor’s Note— The water supply buffer area is shown on the
Regional Infrastructure Overlay Maps.
AO4.5
Accommodation does not occur within 400 metres of a sewerage
treatment plant.
Safety and amenity Table 9.3.5.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
All Visitor Accommodation
Safety and amenity
PO5
Walkways, carparks and publicly accessible facilities, including No acceptable outcome provided
toilets, and bicycle racks are located and designed to allow casual
surveillance by other persons.
PO6
Pathways allow clear sightlines in all directions. No acceptable outcome provided
**FINAL DRAFT Post Consultation 2019**
Page 3 of 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.